Search results for "텔레@tetherzon*^테더수사기관테더트론구매대행"
-
Smart ONE 62.5kvar 400VAC, 440VAC L-L, 62.5kVar Smart One Capacitor Bank for Reactive Power Correction, IP21
Heavy Item - No Free ShippingFastron Electronics Smart ONE 62.5kvar 400VAC L-L, 62.5kVar Smart One Capacitor Bank for Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 5 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Electronics Part Number Smart ONE 62.5kvar 400VAC Function Reactive Power Correction Steps 1 x 12.5kvar, 2 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-550VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
Thyro S 2S Series 2 Leg 3 Phase Solid State Contactor 16 - 1500Amp 400VAC +10/-15% Burst(TAKT) Fire Mode, Economical Firing Mode
Advanced Energy Thyro S 2S Series 2 Leg 3 Phase Solid State Contactor, Burst(TAKT)Firing Mode Only. Compatible Replacement for Eurotherm Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro S 2S 400VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$1,266.46 - $7,229.20
-
PTS-N-3.0M, NTC Temperautre Probe for FRW8 Temperature Control Relay, - 40 to 200 Deg C
Fastron PTS-N-3.0M, NTC Temperautre Probe for FRW8 Temperature Control Relay, - 40 to 200 Deg C NTC probes for FRW8 Series serves to monitor or control simple ON/OFF Temperautre control applications Specification Fastron Part Number PTS-N-2.0M Material 304 SS Operating Temperature Range -40 to 200 Deg C DCabek Material Copper Core silica gel Cable Length 2000mm Datasheet Product Datasheet
$29.00
$34.22 inclGST -
THST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only
Free Aus Post Shipping for $300 SpendTHST18244D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 2000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-2000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-2000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-2000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 3kg Factory Pack Qty 6 Datasheet Product Datasheet
-
48x24mm PID Temperature Controller, 85-265VAC, Type K Thermocouple Input, 8VDC, 20mA (SSR) and 250VAC, 1 Amp Relay Output
Free Aus Post Shipping for $300 Spend48x24mm PID Temperature Controller, 85-265VAC, Type K Thermocouple Input, 8VDC, 20mA (SSR) and 250VAC, 1 Amp Relay Output Features Meets UL and IEC standards UL Recognized for 250VAC High breaking capacity of 1.5 kA @ 250VAC Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation Applications Electrical Appliances POwer Supply Adaptors Switch Mode Power Supplies Avionics In-line protection Specification Temtec Part Number 48x24mm Temperature Controller Control Type ON/OFF Relay and SSR Dual Output Supply Voltage 85- 265VAC Relay Rating 250VAC @ 1 Amp SSR Output Rating 8VDC @ 20mA Dimensions 48 x 24 x 75mm Mounting Style Panel Mount 48 x 24mm Operating Temperature Range -5°C / 50°C Unit Weight 80g Factory Pack Qty 10
-
H-30-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-30 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-30-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-30 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-30 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-30-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-30 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
MT600-16-F432F2, Single Thyristor Module, 600 Amp, 1600V, 70mm Package
Techsem MT600-16-F432F2, Single Thyristor Module, 600 Amp, 1600V, 70mm Package Features Thyristor for line frequency Pressure Contact Technology Electrically insulated base plate Industrial standard package Long-term stability 3600V Isolation 70mm Base Width Applications Power Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Softstart AC motor control AC power control Lighting and temperature control Specification Techsem Part Number MT600-22-F432F2 Vrrm 2200V Diode Configuration Single Thyristor Module IF(av) @ 125 Deg C 600Amp Package Size W:70mm L:176mm D:90mm Itsm 14 kA Tj(max) 125°C I(gt) @ 25 Deg C 250mA Terminals M10 Screw Hole Centres 80mm x 58mm(M6) Gate Terminals Spade (A 2.8 - 0.8 DIN 46244) Weight 1950g Mounting Torque 6 Nm (18 Nm Terminals) Factory Pack Qty 2 Certification UL Listed, ROHS Techsem Headquarters China Datasheet Product Datasheet Alternatives Contact Us for Possible Replacement for alternative suggestion
$379.00
$447.22 inclGST -
TZ800N16KOF, Single Thyristor Module, 800 Amp, 1600V, 70mm Package
Free Aus Post Shipping for $300 SpendInfineon TZ800N16KOF, Single Thyristor Module, 800 Amp, 1600V, 70mm Package Features Thyristor for line frequency Pressure Contact Technology Electrically insulated base plate Industrial standard package Long-term stability 3600V Isolation 70mm Base Width Applications Power Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Softstart AC motor control AC power control Lighting and temperature control Specification Infineon Part Number TZ800N16KOF Vrrm 1600V Diode Configuration Single Thyristor Module IF(av) @ 85 Deg C 819 Amp Package Size W:70mm L:176mm D:90mm Itsm 35 kA VF(to) 0.82V Tj(max) 125°C rF 0.17mΩ I(gt) @ 25 Deg C 250mA Terminals M10 Screw Hole Centres 80mm x 58mm(M6) Gate Terminals Spade (A 2.8 - 0.8 DIN 46244) R th(j-c) 0.042°C/W R th(c-h) 0.015°C/W Weight 1950g Mounting Torque 6 Nm (18 Nm Terminals) Factory Pack Qty 2 Certification UL Listed, ROHS Infineon Headquarters Germany Datasheet Product Datasheet Alternatives Contact Us for Possible Replacement for alternative suggestion
-
FTA-100-010-24, Hall Effect DC Current Transducer, +/-100 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-100-010-24, Hall Effect DC Current Transducer, +/-100 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-100 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-100A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-100-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-100 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-400-010-24, Hall Effect DC Current Transducer, +/-400 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-400-010-24, Hall Effect DC Current Transducer, +/-400 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-400 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-400A ~+/-400A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-400-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-400 Amp Response Time < 1uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 4 Pin Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-030-010-24, Hall Effect DC Current Transducer, +/-30 Amp , +/-10V Bipolar Output, 24VDC supply, 21mm Aperture
FTA-030-010-24, Hall Effect DC Current Transducer, +/-30 Amp , +/-10V Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-30 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-030-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-30 Amp Response Time < 120mS Output Bipolar +/-10V Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
CTS125-24, Contactor SPST-NO, 125 AMP, 6-110VDC, 24VDC Coil, SPDT Auxiliary Contact
Fastron CTS125-24, Contactor SPST-NO, 125 AMP, 6-110VDC, 24VDC Coil, SPDT Auxiliary Contact Features Ideal for switching solenoids Flexible package for installation Specification Fastron Part Number CTS125-24 Main Contact Type SPST-NO Auxiliary Contact Type SPDT Coil Voltage 24VDC Nominal Coil Power Consumption 13 - 25 Watts Max Load Current 125A @ 60VDC Mechanical Life @ 0 Amp 1,000,000 Operations Load Voltage Range 6-110VDC Termination Style Busbar Operating Temperature -40 to 60 Deg C Unit Weight 800g Factory Pack Qty 1 Datasheet Datasheet
$239.00
$282.02 inclGST