Search results for "텔레@tetherzon*^테더수사기관테더트론구매대행"
-
THST6416D-24-500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-500 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-500-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
MFC500-16-416F3, Thyristor Diode Module, 500 Amp, 1600V, to Replace TD425N
Techsem MFC500-16-416F3, Thyristor Diode Module, 500 Amp, 1600V, to Replace TD425N Features Thyristor for line frequency Pressure Contact Technology Electrically insulated base plate Industrial standard package Long-term stability 3600V Isolation 60mm Base Width Applications Power Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Softstart AC motor control AC power control Lighting and temperature control Specification Infineon Part Number MFC500-16-416F3 Vrrm 1600V Diode Configuration Thyristor Diode Module IF(av) @ 85 Deg C 425 Amp Package Size W:60mm L:144mm D:52mm Itsm 14.5 kA VF(to) 0.8V Tj(max) 125°C rF 0.34mΩ I(gt) @ 25 Deg C 250mA Terminals M10 Screw Hole Centres 80mm x 48mm(M6) Gate Terminals Spade (A 2.8 - 0.8 DIN 46244) R th(j-c) 0.078°C/W R th(c-h) 0.02°C/W Weight 1500g Mounting Torque 6 Nm (12 Nm Terminals) Factory Pack Qty 2 Certification UL Listed, ROHS Techsem Headquarters China Datasheet Product Datasheet
$325.00
$383.50 inclGST -
THST6416D-24-600-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-600 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-600-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-600 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-600 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-600-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-600 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
THST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-1000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
THST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-1500-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1500 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-1500-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
Smart ONE 25kvar 400VAC L-L, 25kVar Smart Capacitor Bank for Reactive Power Correction, IP21
Heavy Item - No Free ShippingFastron Electronics Smart ONE 25kvar 400VAC, Smart Capacitor Bank for Kvar Correction, Reactive Power Reduction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 5 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Part Number Smart ONE 25kvar 400VAC Function Reactive Power Correction Steps 1 x 12.5kvar, 1 x 7.5kvar 1 x 5kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-550VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output
Fastron DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output Filter Time Constant Function Converter function 2 Input 1 Output, and 1 Input Two Output Versions available 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-TR Transmitter Output 4-20mA Input Multirange RTD/K/J/R/S/B/E/T/4-20mA/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
$209.00
$246.62 inclGST -
BC-350R-100-063, Pt100 Thermometer 0 to 100 Deg C 1/2" BSP
Free Aus Post Shipping for $300 SpendTel-Tru Thermometer Range: 0…100°C Stem length: 2.5"/63.5mm Process connection: 1/2" BSP Part no: 533.39170276
-
THST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendTHST6416D-24-2000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-2000 Amp DC, RS485 Modbus RTU output, 64x16mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 64 x 16mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST6416D-24-2000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-2000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
THST18244D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-1000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only
Free Aus Post Shipping for $300 SpendTHST18244D-24-1000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 1000Amp DC, +24VDC Supply, 182 x 44 Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-1000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-1000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-1000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 500g Factory Pack Qty 6 Datasheet Product Datasheet
-
THST18244D-24-3000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-3000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only
Free Aus Post Shipping for $300 SpendTHST18244D-24-3000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 3000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-3000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-3000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-3000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 3kg Factory Pack Qty 6 Datasheet Product Datasheet
-
THST18244D-24-5000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, +/-5000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only
Free Aus Post Shipping for $300 SpendTHST18244D-24-5000-RS485, Split Core Bipolar Hall Effect DC Current Transducer, 5000Amp DC, +24VDC Supply, 182 x 44mm Square aperture, RS485 Modbus RTU Measurement Only Compact and versatile Split Core Bipolar DC current sensor, +/-5000 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output 182 x 44mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number THST18244D-24-5000-RS485 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-5000 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 3kg Factory Pack Qty 6 Datasheet Product Datasheet