Fastron Electronics GT-D-C-SP02, 0-150VDC Voltage Transducer, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-D-C-SP02
Control Output
4-20mA
Input
0 - 150VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh Xmer CT Split 155/80 1500/5 Class 0.5 20VA Series Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 155/80 1500/5 SCCT Class 0.5 20VA
Technology
Split Core AC Current Transformer
Ratio
1500/5
Aperture Size
85 x 125mm
VA Rating
20VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
1500Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet
LEM DVL 1500, Digital Voltage Transducer, 1500V, +/-15...24VDC, 50mA output, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Digital Transducer (ASIC based)
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 1500
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 1500V
Measurement Range
+/- 2250V
Output
50 mA @Vpn
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron Electronics GTD-DAO(0-1)-D-11, Signal Conditioner/Current Transducer, 0-1 Amp AC input, 22-60VAC/DC aux, Dual 4-20mA Average RMS outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DAO(0-1)-A-11
Conditioned Output
2 x 4-20mA (Average RMS)
Input
0 -1 Amp RMS
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
SDM230-LORAWAN-MID-AD915, DIN Rail Mount kWh Meter, Single Phase, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms, MID Approved
100 amp Direct Connect
LoRaWaN AU915 communication
Optional Mbus Model available
True RMS values of currents and voltages
1 x Configurable Pule Output (via Display Menu or Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy Class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM230-LORAWAN-MID-AU915
Functions
Single Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
230V L-N 230V L-N, 100 Amp
Maximum Measurement Range
276 L-N 230V L-N,100 Amp
Nominal Current Input
Direct connect 100 Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
36mm x 100mm x 66mm (2 modules wide)
Isolation
4kV
LoRaWaN
LoRaWaN AU915
Weight
250g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Modbus Utility
EEM Meter Setting Software Utility
Fastron FDV-15-420-24, Battery DC Voltage Transducer, Din Rail Mount, 0-15VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-15-420-24
Analogue Output
4-20mA
Input
0-15VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-30-420-24, DC Voltage Transducer, Din Rail Mount, 0-30VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-30-420-24
Analogue Output
4-20mA
Input
0 - 30VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Techsem MD1100-20-432F2, Single Diode Module, 1100 Amp, 2000V
Features
Diode for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
70mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
High Powered Rectifiers
DC Blocking Diodes
Flywheel Diodes
Specification
Techsem Part Number
MD1100-24-432F2
Vrrm
2000V
Diode Configuration
Single Diode Module
IF(av) @ 85 Deg C
1100 Amp
Package Size
W:70mm L:146mm D:90mm
Itsm
34 kA
VF(to)
0.7V
Tj(max)
125°C
rF
0.12mΩ
Terminals
M12 Screw
Hole Centres
80mm x 58mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.042°C/W
R th(c-h)
0.02°C/W
Weight
2.8kg
Mounting Torque
6 Nm (13 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
DZ1070N18K
Contact Us for Possible Replacement
Fastron Electronics BTCD/A-M-A2-DA-TA, PID Controller 96x96mm, 85-265VAC, 4-20mA output 4-20mA Cooling Output, 2 Alarms, Retransmission, Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP56 (front panel only)
CE Approved
Each unit needs just 80 mm depth panel space
Optional Pattern Control Feature
Specification
Fastron Part Number
BTCD/A-M-A2-DA-TA
Control Output
4-20mA
Input
Multirange 4-20mA/RTD/Thermocouple (other linear inputs to be specified at time of order)
Option 1
2nd Alarm
Option 2
4-20mA Cooling, 4-20mA Retransmission
Mounting Style
96 x 96mm Panel Mount
Load Voltage Range
100-240VAC
Termination Style
Screw
Weight
600g
Factory Pack Qty
1
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
LEM FRS 2000-SBI, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coreless Hall effect Technology
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 2000-SU
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
2000 Amp
Measurement Range
+/-6000 Amp
Overload Rating
N/A
Output
4-20mA Bipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Crouzet GN Series 84137870, SSR DC 4-32VDC control, 30A, 50VDC Load, with LED Indicator and IP20 Cover
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
84137870
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
30 Amp DC
Surge Capability (10ms)
75 Amp DC
Special Feature
LED status Indicator and KS101 IP cover
Mounting Style
Panel Mount
Load Voltage Range
0 - 50VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See alternative D1D40K with raised terminals for alternative or D1D80 for higher current alternative. Note both have no IP20 cover, or LED indicator. KS101 IP cover can be purchased here.
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies