Crouzet 88970524, Crouzet Essential Series CT104, 4.3" HMI Touch Screen, 24VDC, RS495 Modbus RTU
TFT-LCD resistive touch screen
Fan less cooling system
32 bit 600 Mhz or 1 Ghz Cortex-A8 processor
Built-in RTC
Direct communication with M3 programming port
Modbus RS485 protocol (drivers for M3, EVO and em4)
Modbus TCP/IP protocol (drivers for M3, EVO and em4)
Integrated VNC server
Additional functions provided by Crouzet Touch programming software (e-mails,recipe database, enhanced security…)
CE mark, cULus listed
Specification
Crouzet Part Number
88970524 (CT104)
Function
Human Machine Interface (Touch Screen)
Nominal Voltage
24VDC (19.2 - 28.8VDC) @ 300mA
Display Size
4.3"
Resolution
480 x 272
Brightness
400 cd/m²
Storage Memory
128MByte
RAM Memory
128MByte
USB
Host USB 2.0
Ethernet
N/A
Port RS232
COM1 Male
Port RS485
COM1 2/4 wires Male, COM3 2 wires Male
Voltage Resistance
500VAC (1 Min)
Dimensions
128 x 102 x 32 mm / 5.04 x 4.02 x 1.26”
Real Time Clock
5 Years with CR2032 Battery
Termination Style
Screw
Weight
250g
Certification
CE
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
HMI Touch Datasheet
HMI Touch Brochure
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Compatibility
Built in Communications driver compatible with Millenium 3, Millenium EVO, and EM4 PLC's. See our PLC Section for Pricing and Specification
Fastron FDV-50-420-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-420-24
Analogue Output
4-20mA
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom DRC3P48D420R Series AC Motor Controller & Solid State Contactor
Features
7.6 Amp AC Semiconductor Motor Controller
Load voltage range up to 600VAC
Fits standard 35mm DIN Rail
LED input status indicator
AC or DC control
Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Built-in Overvoltage Protection
Ultra-efficient thermal management design (Patented)
Spec
Crydom Part Number
DRC3R48D420
Switching Type
DC Load
Approvals
ROHS,UL,CE,IEC
Control Voltage
18-30VAC/DC
Load Current
7.6 Amp (rms)
Surge Capability (10ms)
716 Amp (peak)
Auxiliary Contacts
2 x NO 1 Amp Solid State
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
197g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
TA800E-LY24, Amber LED Bead Replacements for 24AC/DC TRIB, TRI Series Indicators
LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24AC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TA800E-LY24
Functions
LED Indicator Bulb Replacement
Nominal Voltage
24AC/DC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Amber LED
Approvals
CE
Weight
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Crydom HS501DR + A2450EG, Panel or Din Rail Mount Solid State Relay 24VAC Control Input, LED Status, 24-280VAC Output, 10 Amps
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + A2450EG
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
18-36VAC
Load Current
10 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Datasheet
HS501DR
A2450E-G
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
RCS-1800-1000 Three-Phase Flexible Current Sensor System (Rogowski Coils):
The RCS-1800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-1000
Specification
Magnelab Part Number
RCS-1800-1000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
1000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 1000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
6 Inch
Coil Circumference
18 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Crydom CN240A24, Slimline Relay, 15-30VDC Coil, 2 Amp 24-280VAC Load
Features
Output 2Amp @ 250VAC
15-30VDC Control input
DIN Rail Mount
Changeover Contact
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
CN240A24
Switching Type
250VAC 2 Amp Load SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
15-30VDC
Load Current
2 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
250VAC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Datasheet
Relay Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket
Gigavac GX23CCC, Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil, 122cm Flying leads, SPST-NC Auxiliary Contact, IP67, IP69K
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GX23CCC
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NC
Coil Voltage
24VDC
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
122cm Flying Leads
Aux Contact Terminals
122cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
580g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FC5-L-W-1-G-4-C PID Controller, 24VDC with 1 Alarm, RS485 Comms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm, Dual Relay and SSR Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-L-W-1-G-4-C
Control Output
Relay and SSR (Dual Ouptut)
Input
Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
1 Alarm, RS485 Comms
Mounting Style
96x96mm Panel Mount
Supply Voltage
24VDC +/-15%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Crouzet 88886016, Syr-Line Multirange Timer TMR 48 X, 11 Pin, Single Pole 5A CO (SPDT) Delay 0.02s - 300h, 12-240VDC, 24-240VAC, 48x48mm, Functions A1, A2, H1, H2, Q1, Q2, D-Di
TMR 48 X Timers Syrline 48x48mm - 1 Relay 5A :
Multi-Function
Mono Function
Multi-range (0.02 s – 300 h)
Multi-voltage (12-240VDC/24-240 V AC)
2 x CO relay outputs (Changeover)
DIN Sized (48x48 mm) Housing
Compact body (64.5 mm long)
Water & Dust-proof (IP50)
11-Pin
Multifunction Timers Include The Following :
A1, A2, H1, H2, Q1, Q2, D-Di
Specification
Crouzet Part Number
88886016
Function
Multifunction & Mono Function TimerA1, A2, H1, H2, Q1, Q2, D-Di
Nominal Voltage
12 - 240VDC / 24 → 240 VAC
Digital Output
2 x C/O (SPDT) (Changeover -Single Pole Double Throw), 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 0.02→300h
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Memory
N/A
Isolation
1kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
11 Pin Base
Weight
80g
Certification
CE, cULus,CCC, ROHS, Reach, WEEE
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP50 (Front), IP40 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Crydom D2475, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load
Features
• Ratings from 25A to 125 Amp @ 24-280 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
D2475
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
40 Amp (rms)
Surge Capability
954 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Please note Changes from Gen 3 to Gen 4 (current) package design here
Alternatives
See HD48125 or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies