  • FGM6S-3P-160M 63A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 63 Amp, 400/690VAC FGM6S-3P-160M 63A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 63 Amp, 400/690VAC

    FGM6S-3P-160M 63A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 63 Amp, 400/690VAC

    Out of stock

    Trent MOD1 3NM 63A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 63 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-160M 63A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 63 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $179.00
    $211.22 inclGST

  • FGM6S-3P-160M 80A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 40 Amp, 400/690VAC FGM6S-3P-160M 80A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 40 Amp, 400/690VAC

    FGM6S-3P-160M 80A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 40 Amp, 400/690VAC

    Out of stock

    Trent FGM6S-3P-160M 80A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 80 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-160M 80A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 80 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $205.00
    $241.90 inclGST

  • FGM6S-3P-160M 100A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 100 Amp, 400/690VAC FGM6S-3P-160M 100A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 100 Amp, 400/690VAC

    FGM6S-3P-160M 100A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 100 Amp, 400/690VAC

    Out of stock

    Trent FGM6S-3P-160M 100A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 100 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-160M 100A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 100 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $205.00
    $241.90 inclGST

  • FGM6S-3P-250H 160A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=50kA 160 Amp, 400/690VAC FGM6S-3P-250H 160A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=50kA 160 Amp, 400/690VAC

    FGM6S-3P-250H 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=50kA 160 Amp, 400/690VAC

    Out of stock

    Trent FGM6S-3P-250H 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 50kA 160 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-250H 160A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 160 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    Out of stock

    $259.00
    $305.62 inclGST

  • FGM6S-3P-400H 400A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 400 Amp, 400/690VAC FGM6S-3P-400H 400A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 400 Amp, 400/690VAC

    FGM6S-3P-400H 400A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 400 Amp, 400/690VAC

    10 pcs in stock

    Trent FGM6S-3P-400H 400A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 400 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-400H 400A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 400 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 5.1kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    10 pcs in stock

    $609.00
    $718.62 inclGST

  • MOD3 3NH 315A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 315 Amp, 400/690VAC-3 Pole Moulded Case Circuit Breakers-Trent-Fastron Electronics Store

    FGM6S-3P-400H 315A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 315 Amp, 400/690VAC

    10 pcs in stock

    Trent FGM6S-3P-400H 315A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 315 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-400H 315A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 315 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 5.1g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    10 pcs in stock

    $579.00
    $683.22 inclGST

  • FGM6S-3P-630H 500A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 500 Amp, 400/690VAC FGM6S-3P-630H 500A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 500 Amp, 400/690VAC

    FGM6S-3P-630H 500A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 500 Amp, 400/690VAC

    10 pcs in stock

    Trent FGM6S-3P-630H 500A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 500 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-630H 500A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 500 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 6.9kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    10 pcs in stock

    $899.00
    $1,060.82 inclGST

  • FGM6S-3P-630H 630A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 630 Amp, 400/690VAC FGM6S-3P-630H 630A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 630 Amp, 400/690VAC

    FGM6S-3P-630H 630A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 630 Amp, 400/690VAC

    9 pcs in stock

    Trent FGM6S-3P-630H 630A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 630 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-630H 630A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 630 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 6.9kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    9 pcs in stock

    $969.00
    $1,143.42 inclGST

  • FGM6S-3P-800H 800A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 800 Amp, 400/690VAC FGM6S-3P-800H 800A,  3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 800 Amp, 400/690VAC

    FGM6S-3P-800H 800A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 800 Amp, 400/690VAC

    10 pcs in stock

    Trent FGM6S-3P-800H 800A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 800 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-800H 800A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 800 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 8kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    10 pcs in stock

    $1,015.00
    $1,197.70 inclGST

  • ROT-FGM6-160, Extended Rotary Handle for 3 POLE MCCB FGM6-160 Frame Size ROT-FGM6-160, Extended Rotary Handle for 3 POLE MCCB FGM6-160 Frame Size

    ROT-FGM6-160, Extended Rotary Handle for 3 POLE MCCB FGM6-160 Frame Size

    50 pcs in stock

    Trent ROT-FGM6-160, Extended Rotary Handle for 3 POLE MCCB FGM6-160 Frame Size Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Rotary handle mounts directly on MCCB with screws (included) without removal of midcover Clear ON/OFF/TRIP Direct access to push to trip button with rotary handle mounted Datasheet Product Datasheet

    50 pcs in stock

    $49.00
    $57.82 inclGST

  • ROT-FGM6-400, Extended Rotary Handle for 3 POLE MCCB FGM6-400 Frame Size ROT-FGM6-400, Extended Rotary Handle for 3 POLE MCCB FGM6-400 Frame Size

    ROT-FGM6-400, Extended Rotary Handle for 3 POLE MCCB FGM6-400 Frame Size

    50 pcs in stock

    Trent ROT-FGM6-400, Extended Rotary Handle for 3 POLE MCCB FGM6-400 Frame Size Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Rotary handle mounts directly on MCCB with screws (included) without removal of midcover Clear ON/OFF/TRIP Direct access to push to trip button with rotary handle mounted Datasheet Product Datasheet

    50 pcs in stock

    $55.00
    $64.90 inclGST

  • ROT-FGM6-630, Extended Rotary Handle for 3 POLE MCCB FGM6-630 Frame Size ROT-FGM6-630, Extended Rotary Handle for 3 POLE MCCB FGM6-630 Frame Size

    ROT-FGM6-630, Extended Rotary Handle for 3 POLE MCCB FGM6-630 Frame Size

    50 pcs in stock

    Trent ROT-FGM6-630, Extended Rotary Handle for 3 POLE MCCB FGM6-630 Frame Size Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Rotary handle mounts directly on MCCB with screws (included) without removal of midcover Clear ON/OFF/TRIP Direct access to push to trip button with rotary handle mounted Datasheet Product Datasheet

    50 pcs in stock

    $59.00