Trent 200BBF Series 690V, 200 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Features
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1000 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
200BBF
Fuse Type
I²t aR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating
Nominal Current (RMS + DC)
200 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
79.4 x 24 x 110mm
Hole Centers
75.2 x 93.6mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
62W
Termination Style
M6
Unit Weight
400g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Cross Reference Chart
Trent 225BBF Series 690V, 225 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Features
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1000 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
225BBF
Fuse Type
I²t aR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating
Nominal Current (RMS + DC)
225 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
79.4 x 24 x 110mm
Hole Centers
75.2 x 93.6mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
62W
Termination Style
M6
Unit Weight
400g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Cross Reference Chart
Trent 300BBF, Series 690V, 300 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Features
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1000 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
300BBF
Fuse Type
I²t aR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (IP < 30IN)
75000 A²/s
Nominal Current (RMS + DC)
400 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
79.4 x 24 x 110mm
Hole Centers
75.2 x 93.6mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
59W
Termination Style
M6
Unit Weight
400g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Cross Reference Chart
Trent FKM111AR, Mosfet Single, 150 Amp, 100V, Medium Fast, OEM Drop in Replacement for SKM111AR, Can Be used to detect Earth Faults
Features
Mosfet
Pressure Contact Technology
Electrically insulated base plate
Press Mounted Style
2500V Isolation
61mm Base Width
NBR Non Genuine replacement part. Reverse engineered and tested to SKM111AR
Applications
Frequency Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Inverter
Drives
Specification
Trent Part Number
NBR-SKM111AR
Vces
100V
Transistor Configuration
Single Mosfet
Ic(nom) @ 80 Deg C
150 Amp
Package Size
W:42mm L:80mm D:30mm
Tj(max)
150°C
Terminals
M6 Screw
Hole Centres
93 x 48mm(M6)
Gate Terminals
M5/Faston
Weight
130g
Mounting Torque
5 Nm (4 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Trent Headquarters
Australia
Â
Datasheet
Product Datasheet
TRENT TG-63H 1P/10/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 10 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/10/C/10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
10 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TG-63H 1P/16/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 16 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/16/C/10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
16 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TG-63H 1P/63/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 63 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/63/C/10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
63 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TG-63H 1P/50/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 50 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/50/C/10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
50 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TG-63H 1P/40/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 40 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/40/C/10kA,
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
40 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TG-63H 1P/32/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 32 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/32/C/10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
32 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TG-63H 1P/25/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 25 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/25/C/10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
25 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TG-63H 1P/20/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 20 Amp, 10kA, 400VAC
Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB
Specification
TRENT Part Number
TG-63H 1P/20/C/10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
400VAC @ 50/60Hz
Nominal Current Range
20 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet