Trent OEM Pricing Collection
-
FGM6SM-4P-800H 700A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Fixed Type ICS=75kA 700 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-630H 1250A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Fixed Type 75kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-630H 1250A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 85kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 16kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
-
FGM6SM-4P-800H-800A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Fixed Type ICS=75kA 800 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-630H 1000A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Fixed Type 75kA 800 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-630H 1000A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 800 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 16kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
-
FGM6S-4P-160M 63A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 63 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent MOD1 3NM 63A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 63 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-160M 63A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 63 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
-
FGM6S-4P-160M 80A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 40 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-160M 80A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 80 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-160M 80A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 80 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
-
FGM6S-4P-160M 100A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 100 Amp, 400/690VAC
Trent FGM6S-4P-160M 100A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 100 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-160M 100A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 100 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$205.00
$241.90 inclGST -
FGM6S-4P-250H 160A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=50kA 160 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-250H 160A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 50kA 160 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-250H 160A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 160 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
FGM6S-4P-400H 400A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 400 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-400H 400A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 400 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-400H 400A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 400 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 5.1kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
-
FGM6S-4P-400H 315A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 315 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-400H 315A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 315 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-400H 315A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 315 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 5.1g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
-
FGM6S-4P-630H 500A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 500 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-630H 500A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 500 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-630H 500A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 500 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 6.9kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
-
FGM6S-4P-630H 630A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=75kA 630 Amp, 400/690VAC
Heavy Item - No Free ShippingTrent FGM6S-4P-630H 630A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 75kA 630 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-4P-630H 630A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 630 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 6.9kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
-
NBR-A100P1000-4, Amptrap Semiconductor Fuse, 1000 Amp, 750VAC/1000VDC, Form 101, 100kA
Trent A100P1000-4, Amptrap Semiconductor Fuse, 1000 Amp, 750VAC/1000VDC, Form 101, 100kA, Name Brand Replacement Features Square Body DIN 43 653 Wide Range of I²t Ratings up to 2000 Amp Busbar or Fuse Holder Mounted IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number NBR-A100P1000-4 Fuse Type I²t AR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (660V) Nominal Current (RMS + DC) 1000 Amp Tested Breaking Capacity 100kA @ 750VAC/1000VDC Dimensions 209 x 85.9mm Hole Centers  148-167mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watts Dissipation 125W Termination Style M10 Unit Weight 1500g Factory Pack Qty 10  Datasheet Product Datasheet
$349.00
$411.82 inclGST -
NBR-FWP-600A 700V AC/DC, Semiconductor Fuse, 600 Amp, 700VAC/DC, Round Barrel 7.09 x 2.0 x 2.5 Inches. Clearing I2t 250kA, Breaking Capacity 200kAand Microswitch
Trent I²t Semiconductor Fuse, NBR-FWP-600A 700V AC/DC, Semiconductor Fuse, 600 Amp, 700VAC/DC, Round Barrel 7.09 x 2.0 x 2.5 Inches. Clearing I2t 250kA, Breaking Capacity 200kAand Microswitch Features Square Body DIN 43 653 Wide Range of I²t Ratings up to 2000 Amp Busbar or Fuse Holder Mounted IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Fuse Blown Indicator and Microswitch Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number NBR-FWP-600A 700V AC/DC Fuse Type I²t AR Class Nominal Voltage 700VAC @ 50Hz I²t Rating (660V) 250000A²/s Nominal Current (RMS + DC) 600 Amp Tested Breaking Capacity 200kA @ 700VAC/DC Dimensions 138 x 61 x 50mm Hole Centers 108mm + Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watts Dissipation 75W Termination Style M10 Unit Weight 350g Factory Pack Qty 10  Datasheet Product Datasheet
$179.00
$211.22 inclGST