Trent OEM Pricing Collection
-
TC-FGM6S-4P-400, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLY
Trent TC-FGM6S-4P-400, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLY Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-4P-400 Functions 4 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$12.00
$14.16 inclGST -
TC-FGM6S-4P-250, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLY
Trent TC-FGM6S-4P-250, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLYÂ Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-4P-250 Functions 4 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$12.00
$14.16 inclGST -
TC-FGM6S-4P-160, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 160, 1 PC ONLY
Trent TC-FGM6S-4P-160, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 160, 1 PC ONLYÂ Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-4P-160 Functions 4 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$12.00
$14.16 inclGST -
TC-FGM6S-630, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY
Trent TC-FGM6S-630, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLYÂ Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-630 Functions 3 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$12.00
$14.16 inclGST -
TC-FGM6S-3P-400, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLY
Trent TC-FGM6S-3P-400, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLYÂ Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-3P-400 Functions 3 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$15.00
$17.70 inclGST -
TC-FGM6S-3P-250, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLY
Trent TC-FGM6S-3P-250, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLYÂ Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-3P-250 Functions 3 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$12.00
$14.16 inclGST -
TC-FGM6S-3P-160, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 160, 1 PC ONLY
Trent TC-FGM6S-3P-160, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 160, 1 PC ONLYÂ Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-3P-160 Functions 3 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$12.00
$14.16 inclGST -
FGM6S-3P-125H 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=25kA 125 Amp, 400/690VAC
Trent FGM6S-3P-125H 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 125 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-125H 125A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 125 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$205.00
$241.90 inclGST -
FGM6S-3P-160M 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 160 Amp, 400/690VAC
Trent FGM6S-3P-160M 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 160 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-160M 160A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 160 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$205.00
$241.90 inclGST -
FGM6S-3P-160M 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type ICS=36kA 125 Amp, 400/690VAC
Trent FGM6S-3P-160M 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 36kA 125 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6S-3P-160M 125A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 125 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$205.00
$241.90 inclGST -
TC-FGM6DC-3P-400, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLY
Trent TC-FGM6DC-400 100A, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLYÂ Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6DC-400 Functions Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker Frame Size 400 Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$15.00
$17.70 inclGST -
TC-FGM6DC-3P-250, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 250/320, 1 PC ONLY
Trent TC-FGM6DC-250, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLYÂ Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6DC-250 Functions Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker Frame Size 250 or 320Â Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$16.00
$18.88 inclGST