Trent OEM Pricing Collection

783 products

  • Last stock! FGM6DC-3PLC-800 800A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 800 Amp, 1500VDC, 3 POLE CONNECTING TYPE FGM6DC-3PLC-800 800A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 800 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    FGM6DC-3PLC-800 800A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 800 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    3 pcs in stock

    Trent FGM6DC-3PLC-800 800A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 800 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 25kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-3PLC-800 800A Functions 3 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 800 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 25kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 8.5kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    3 pcs in stock

    $695.00
    $820.10 inclGST

  • FGM6DC-3PLC-800 700A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 700 Amp, 1500VDC, 3 POLE CONNECTING TYPE FGM6DC-3PLC-800 700A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 700 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    FGM6DC-3PLC-800 700A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 700 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    Out of stock

    Trent FGM6DC-3PLC-800 700A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 700 Amp, 1500VDC, 3 POLE CONNECTING TYPE Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 25kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-3PLC-800 700A Functions 3 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 800 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 25kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 8.5kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $695.00
    $820.10 inclGST

  • Last stock! FGM6DC-3PLC-630 630A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 630 Amp, 1500VDC, 3 POLE CONNECTING TYPE FGM6DC-3PLC-630 630A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 630 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    FGM6DC-3PLC-630 630A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 630 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    4 pcs in stock

    Trent FGM6DC-3PL-630 630A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 630 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 25kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-3PLC-630 630A Functions 3 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 630 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 25kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 8.5kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    4 pcs in stock

    $595.00
    $702.10 inclGST

  • FGM6DC-3PLC-630 500A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 500 Amp, 1500VDC, 3 POLE CONNECTING TYPE FGM6DC-3PLC-630 500A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 500 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    FGM6DC-3PLC-630 500A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 500 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    6 pcs in stock

    Trent FGM6DC-3PL-500 500A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 630 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 25kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-3PLC-630 500A Functions 3 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 500 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 25kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 8.5kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    6 pcs in stock

    $595.00
    $702.10 inclGST

  • Last stock! FGM6DC-3PLC-400 350A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 350 Amp, 1500VDC, 3 POLE CONNECTING TYPE FGM6DC-3PLC-400 350A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 350 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    FGM6DC-3PLC-400 350A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 350 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    4 pcs in stock

    Trent FGM6DC-3PL-400 350A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 350 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 25kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-3PL-400 350A Functions 3 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 350 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 25kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 8.5kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    4 pcs in stock

    $495.00
    $584.10 inclGST

  • FGM6DC-3PLC-400 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 315 Amp, 1500VDC, 3 POLE CONNECTING TYPE FGM6DC-3PLC-400 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 315 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    FGM6DC-3PLC-400 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 315 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    Out of stock

    Trent FGM6DC-3PL-400 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 315 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 25kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-3PL-400 315A Functions 3 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 315 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 25kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 8.5kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $400.00
    $472.00 inclGST

  • TC-FGM6DC-2P-800, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLY

    TC-FGM6DC-2P-800, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLY

    Out of stock

    Trent TC-FGM6DC-2P-800 100A, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLY  Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6DC-2P-800 Functions Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker Frame size 800 Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $15.00
    $17.70 inclGST

  • TC-FGM6DC-2P-630, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY

    TC-FGM6DC-2P-630, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY

    24 pcs in stock

    Trent TC-FGM6DC-2P-630 100A, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY  Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6DC-2P-630 Functions Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker Frame Size 630 Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    24 pcs in stock

    $15.00
    $17.70 inclGST

  • TC-FGM6DC-3P-800, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLY

    TC-FGM6DC-3P-800, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLY

    24 pcs in stock

    Trent TC-FGM6DC-3P-800, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLY  Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6DC-3P-800 Functions Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker Frame Size 800 Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    24 pcs in stock

    $15.00
    $17.70 inclGST

  • TC-FGM6DC-3P-630, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY

    TC-FGM6DC-3P-630, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY

    24 pcs in stock

    Trent TC-FGM6DC-630, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY  Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6DC-630 Functions Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker Frame Size 630 Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    24 pcs in stock

    $15.00
    $17.70 inclGST

  • FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release

    120 pcs in stock

    Trent FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M21 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 17 - 23 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    120 pcs in stock

    $68.00
    $80.24 inclGST

  • TC-FGM6S-4P-630, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY

    TC-FGM6S-4P-630, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY

    Out of stock

    Trent TC-FGM6S-4P-630, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLY  Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-4P-630 Functions 4 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $12.00
    $14.16 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account