Trent OEM Pricing Collection
-
FGM6SM-3P-250H 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=50kA 160 Amp, 400/690VAC
Trent FGM6SM-3P-250H 160A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 50kA 160 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-3P-250H 160A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 160 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$259.00
$305.62 inclGST -
FGM6SM-3P-160M 100A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=36kA 100 Amp, 400/690VAC
Trent FGM6SM-3P-160M 100A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 36kA 100 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-3P-160M 100A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 100 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$205.00
$241.90 inclGST -
FGM6SM-3P-160M 80A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=36kA 40 Amp, 400/690VAC
Trent FGM6SM-3P-160M 80A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 36kA 80 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-3P-160M 80A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 80 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$205.00
$241.90 inclGST -
FGM6SM-3P-160M 63A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=36kA 63 Amp, 400/690VAC
Trent MOD1 3NM 63A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 36kA 63 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-3P-160M 63A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 63 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$179.00
$211.22 inclGST -
FGM6SM-3P-800H 700A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=75kA 700 Amp, 400/690VAC
Trent FGM6SM-3P-800H 700A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 75kA 1000 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-3P-800H 700A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1000 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 16kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$1,015.00
$1,197.70 inclGST -
FGM6SM-3P-250H 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=50kA 125 Amp, 400/690VAC
Trent FGM6SM-3P-250H 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 50kA 125 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-3P-250H 125A Functions MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 125 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$199.00
$234.82 inclGST -
FGM6SM-4P-630H 630A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=75kA 630 Amp, 400/690VAC
Trent FGM6SM-4P-630H 630A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 75kA 630 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-630H 630A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 630 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 6.9kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$969.00
$1,143.42 inclGST -
FGM6SM-4P-630H 500A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=75kA 500 Amp, 400/690VAC
Trent FGM6SM-4P-630H 500A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 75kA 500 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-630H 500A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 500 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 6.9kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$1,015.00
$1,197.70 inclGST -
FGM6SM-4P-400H 315A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=75kA 315 Amp, 400/690VAC
Trent FGM6SM-4P-400H 315A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 75kA 315 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-400H 315A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 315 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 5.1g Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$579.00
$683.22 inclGST -
FGM6SM-4P-400H 400A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=75kA 400 Amp, 400/690VAC
Trent FGM6SM-4P-400H 400A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 75kA 400 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-400H 400A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 400 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 5.1kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$609.00
$718.62 inclGST -
FGM6SM-4P-250H 160A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=50kA 160 Amp, 400/690VAC
Trent FGM6SM-4P-250H 160A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 50kA 160 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-250H 160A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 160 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$259.00
$305.62 inclGST -
FGM6SM-4P-160M 100A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=36kA 100 Amp, 400/690VAC
Trent FGM6SM-4P-160M 100A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 36kA 100 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-160M 100A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 100 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Â Datasheet Product Datasheet
$205.00
$241.90 inclGST