  • FT400160P, 4000/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm FT400160P, 4000/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm

    FT400160P, 4000/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm

    6 pcs in stock

    FT400160P, 4000/5 Amp Split Core CT, Class 0.5 15VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FT400160P Technology Split Core AC Current Transformer Ratio 4000/5 Aperture Size 80 x 160mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 4000Amp x 1.2 Termination Style Screw Approvals UL, CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide

    6 pcs in stock

    $281.00
    $331.58 inclGST

  • Last stock! TT 50-SD, Current Transformer, 50 Amp, 16,66mA Output

    TT 50-SD, Current Transformer, 50 Amp, 16,66mA Output

    1 pcs in stock

    LEM TT 50-SD Series Current Transformer (, Obsolete) Features Quick Release Split Core System Ø 8 mm sensing aperture for noncontact measurementMounting Feet Supplied Self Powered Cable output (1m) Rated System Voltage 0.30/3.5kV Isolated plastic case recognized according to UL 94-V0 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification LEM Part Number TT 50-SD Technology Split Core AC Current Transformer Ratio 50/16.66mA Aperture Size ? 8mm Protection Degree IP40 Accuracy Class Class 1 Output 16.66 mA AC (+20%) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 50Amp x 1.2 Termination Style 1m Flying Lead Unit Weight 80g Factory Pack Qty 9 Datasheet Product Datasheet Alternatives This part is , Obsolete. Contact Us for Possible Replacement for replacement

    1 pcs in stock

    $46.60
    $54.99 inclGST

  • FESCT-32-300-0.333V, 300Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store FESCT-32-300-0.333V, 300Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    FESCT-32-300-0.333V, 300Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 32x32mm Aperture

    30 pcs in stock

    Fastron Electronics FESCT-32-300-0.333V, 300Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/2kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number FESCT-32-300-0.333V Technology Split Core AC Current Transformer Ratio 300/0.333V Aperture Size 32 x 32mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 300Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    30 pcs in stock

    $80.00
    $94.40 inclGST

  • FESCT-32-250-0.333V, 250Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store FESCT-32-250-0.333V, 250Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    FESCT-32-250-0.333V, 250Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 32x32mm Aperture

    12 pcs in stock

    Fastron Electronics FESCT-32-250-0.333V, 250Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/2kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number FESCT-32-250-0.333V Technology Split Core AC Current Transformer Ratio 250/0.333V Aperture Size 32 x 32mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 250Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    12 pcs in stock

    $80.00
    $94.40 inclGST

  • FESCT-32-600-0.333V, 600Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store FESCT-32-600-0.333V, 600Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    FESCT-32-600-0.333V, 600Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 32x32mm Aperture

    18 pcs in stock

    Fastron Electronics FESCT-32-600-0.333V, 600Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/2kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number FESCT-32-600-0.333V Technology Split Core AC Current Transformer Ratio 600/0.333V Aperture Size 32 x 32mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 600Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    18 pcs in stock

    $80.00
    $94.40 inclGST

  • Rish Xmer 155/80 1000/5 Split Core CT Class 1 15VA, 80 x 120mm Aperture-Split Core AC Current Transformer-Rishabh Instruments-Fastron Electronics Store Rish Xmer 155/80 1000/5 Split Core CT Class 1 15VA, 85 x 125mm Aperture

    Rish Xmer 155/80 1000/5 Split Core CT Class 1 15VA, 85 x 125mm Aperture

    15 pcs in stock

    Rishabh Rish Xmer 155/80 1000/5 Split Core CT Class 1 15VA, 85 x 125mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish Xmer 155/80 1000/5 SCCT Class 1 15VA Technology Split Core AC Current Transformer Ratio 1000/5 Aperture Size 85 x 125mm VA Rating 15VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet  

    15 pcs in stock

    $295.00
    $348.10 inclGST

  • SCT-F36-300-5A, 5 Amp, 300Amp Measurement, Class 1 Split Core CT's SCT-F36-300-5A, 5 Amp, 300Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-300-5A, 5 Amp, 300Amp Measurement, Class 1 Split Core CT's

    88 pcs in stock

    Fastron Electronics SCT-F36-300-5A, 5 Amp, 300Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-300-5A Technology Split Core AC Current Transformer Ratio 300/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    88 pcs in stock

    $66.50
    $78.47 inclGST

  • SCT-F36-500-5A, 5 Amp, 500Amp Measurement, Class 1 Split Core CT's SCT-F36-500-5A, 5 Amp, 500Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-500-5A, 5 Amp, 500Amp Measurement, Class 1 Split Core CT's

    40 pcs in stock

    Fastron Electronics SCT-F36-500-5A, 5 Amp, 500Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F36-500-5A Technology Split Core AC Current Transformer Ratio 500/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    40 pcs in stock

    $66.50
    $78.47 inclGST

  • SCT-F16-120-40mA(SCT-F16-120-040A), 40mA, 120Amp Measurement, Class 1 Split Core CT's SCT-F16-120-040A, 40mA, 120Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F16-120-40mA(SCT-F16-120-040A), 40mA, 120Amp Measurement, Class 1 Split Core CT's

    71 pcs in stock

    Fastron Electronics SCT-F16-120-40mA(SCT-F16-120-040A), 40mA, 120Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 40 mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F16-120-040A Technology Split Core AC Current Transformer Ratio 120/40mA Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 40 mAmp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 120Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    71 pcs in stock

    $48.00
    $56.64 inclGST

  • SCT-F10-20-0.2V, 200mV, 20Amp Measurement, Class 1 Split Core CT's Class 1 SCT-F10-20-0.2V, 200mV, 20Amp Measurement, Class 1 Split Core CT's Class 1

    SCT-F10-20-0.2V, 200mV, 20Amp Measurement, Class 1 Split Core CT's Class 1

    6 pcs in stock

    Fastron Electronics SCT-F10-20-0.2V, 200mV, 20Amp measurement Split Core CT's Class 1 with 0.5M flying leads Features Quick Release Split Core System Cable Mount 200mV Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F10-20-0.2V Technology Split Core AC Current Transformer Ratio 20/200mV Aperture Size ø 10 mm VA Rating N/A Accuracy Class Class 1 Output 200mV (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 20Amp x 1.2 Termination Style 0.5M Flying Leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    6 pcs in stock

    $44.20
    $52.16 inclGST

  • Last stock! SCT-F10-50-0.2V, 200mV, 50Amp Measurement, Class 1 Split Core CT's Class 1 SCT-F10-50-0.2V, 200mV, 50Amp Measurement, Class 1 Split Core CT's Class 1

    SCT-F10-50-0.2V, 200mV, 50Amp Measurement, Class 1 Split Core CT's Class 1

    3 pcs in stock

    Fastron Electronics SCT-F10-50-0.2V, 200mV, 50Amp measurement Split Core CT's Class 1 with 0.5M flying leads Features Quick Release Split Core System Cable Mount 200mV Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F10-50-0.2V Technology Split Core AC Current Transformer Ratio 50/200mV Aperture Size ø 10 mm VA Rating N/A Accuracy Class Class 1 Output 200mV (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 50Amp x 1.2 Termination Style 0.5M Flying Leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    3 pcs in stock

    $44.20
    $52.16 inclGST

  • SCT-F24-100-0.2V, 200mV, 100Amp Measurement Class 1 Split Core CT's for Power Quality Analysers 2mV/Amp-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F24-100-0.2V, 200mV, 100Amp Measurement Class 1 Split Core CT's for Power Quality Analysers 2mV/Amp-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F24-100-0.2V, 200mV, 100Amp Measurement, Class 1 Class 1 Split Core CT's for Power Quality Analysers 2mV/Amp

    6 pcs in stock

    Fastron Electronics SCT-F24-100-0.2V, 200mV, 100Amp Measurement Class 1 Split Core CT's for Power Quality Analysers 2mV/Amp Features Quick Release Split Core System Cable Mount 200mV Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F24-100-0.2V Technology Split Core AC Current Transformer Ratio 100/200mV Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 200mV (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide

    6 pcs in stock

    $55.25
    $65.20 inclGST

Login

Forgot your password?

Don't have an account yet?