AP 50 B420L, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, Average RMS 4-20mA output, Infinite Overload Capability
LEM AP 50 B420L, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, Average RMS 4-20mA output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 10, 20, 50 Amp Average RMS 4-20mA output Features Split Core Average RMS output 4-20mA current output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 50 B420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 10,20,50 Amp Selectable Overload Infinite Output 4-20mA Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$235.65
$278.07 inclGST -
AP 400 B10, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 10V/5V output, Infinite Overload Capability
Free Aus Post Shipping for $300 SpendLEM AP 400 B10, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 200, 300, 400 Amp Average RMS. Selectable 0-5V, 0-10V output Features Split Core Average RMS output 0-10V/0-5V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 400 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 200,300,400 Amp Selectable Overload Infinite Output 0-10V/0-5V Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
AP 100 B420L, Split Core AC Current Sensor, selectable 50, 75,100 Amp, Average RMS 4-20mA output, Infinite Overload Capability
LEM AP 100 B420L, Split Core AC Current Sensor, selectable 50, 75,100 Amp, Average RMS 4-20mA output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 50, 75, 100Amp Average RMS 4-20mA output Features Split Core Average RMS output 4-20mA process output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 100 B420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 50, 75, 100 Amp Selectable Overload Infinite Output 4-20mA Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$282.00
$332.76 inclGST -
AP 200 B420L, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 4-20mA output, Infinite Overload Capability
LEM AP 200 B420L, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 4-20mA output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 100, 150, 200 Amp Average RMS 4-20mA output Features Split Core Average RMS output 4-20mA current output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 200 B420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 50,100, 200 Amp Selectable Overload Infinite Output 4-20mA Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$282.00
$332.76 inclGST -
AP 400 B420L, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 4-20mA output, Infinite Overload Capability
LEM AP 400 B420L, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 4-20mA output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 200, 300, 400 Amp Average RMS 4-20mA output Features Split Core Average RMS output 4-20mA current output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 400 B420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 200,300,400 Amp Selectable Overload Infinite Output 4-20mA Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$282.00
$332.76 inclGST -
AP 50 B10, AC Current Transformer, 24VDC Powered, Selectable 10,25,50 Amp, Average RMS 0-5V,0-10V output, Infinite Overload Capability
LEM AP 50 B10, AC Current Transformer, 24VDC Powered, Selectable 10,25,50 Amp, Average RMS 0-5V,0-10V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 10, 20, 50 Amp Average RMS. Selectable 0-5V, 0-10V output Features Split Core Average RMS output 0-10V/0-5V voltage output Busbar, or Din Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 50 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 10,20,50 Amp Selectable Overload Infinite Output 0-10V/0-5V Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$295.00
$348.10 inclGST -
APR 100 B10, Split Core AC Current Sensor, selectable 50, 75, 100 Amp, True RMS 10V/5V output, Infinite Overload Capability
Free Aus Post Shipping for $300 SpendLEM APR 100 B10, Split Core AC Current Sensor, selectable 50, 75, 100 Amp, True RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 50, 75, 200 Amp True RMS. 0-5/0-10V output selectable Features Split Core True RMS output 0-10V/0-5V voltage output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number APR 100 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 50,75,100 Amp Selectable Overload Infinite Output 0-10V/0-5V True RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
APR 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, True RMS 10V/5V output, Infinite Overload Capability
Free Aus Post Shipping for $300 SpendLEM APR 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, True RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 100, 150, 200 Amp True RMS. Selectable 0-5V, 0-10V output Features Split Core True RMS output 0-5/0-10V voltage output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 200 B420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 100,150, 200 Amp Selectable Overload Capability Infinite Output 0-5V, 0-10VTrue RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
APR 400 B10, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, True RMS 10V/5V output, Infinite Overload Capability
Free Aus Post Shipping for $300 SpendLEM APR 400 B10, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, True RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 200, 300, 400 Amp True RMS. Selectable 0-5V, 0-10V output Features Split Core True RMS output 0-10V/0-5V voltage output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Low power consumption. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number APR 400 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 200,300,400 Amp Selectable Overload Infinite Output 0-10V/0-5V True RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
APR 50 B10, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 10V output, Infinite Overload Capability
Free Aus Post Shipping for $300 SpendLEM APR 50 B10, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 10V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 10, 20, 50 Amp True RMS. Selectable 0-5V, 0-10V output Features Split Core True RMS output 0-10V/0-5V voltage output Busbar, or Din Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number APR 50 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 10,20,50 Amp Selectable Overload Infinite Output 0-10V/0-5V True RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
APR 50 B420L, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 4-20mA output, Infinite Overload Capability
LEM APR 50 B420L, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 4-20mA output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 10, 20, 50 Amp True RMS 4-20mA output Features Split Core True RMS output 4-20mA current output Busbar, or Din Rail Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 50 B420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Powered Nominal Current (RMS + DC) 10,20,50 Amp Selectable Overload Infinite Output 4-20mA True RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$324.47
$382.87 inclGST -
AK 200 C10, AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 0-10V output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AK 200 C10 Series Solid Core AC/DC Hall Effect Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core Average RMS output 0-10V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will nto drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 200 C10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (RMS + DC) 100,150,200 Amp Selectable Maximum Measurement Current (Peak) 120,180,240 Amp Output 0-10V Average RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition