Single Phase Rogowski Coils

16 products

  • LEM International SA Rogowski Coil AI-PMUL Universal Integrator for Rogowski Coils, Multi Range Input and Output, up to 5000Amp Measurement, Din Rail Mount FE-Integrator AI-PMUL

    AI-PMUL Universal Integrator for Rogowski Coils, Input (100 to 5000 Amp) and Output (0.333V,0.225V), and True RMS outputs (4-20mA,0-20mA,0-5V,0-10V), Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount

    50 pcs in stock

    LEM AI-PMUL Universal Integrator for Rogowski Coils, Multi Range Input (100 to 5000 Amp) and Output (0.333V,0.225), and True RMS outputs (4-20mA,0-20mA,0-5V,0-10V), Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both True RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. optional Input signal Accuracy Class 0.5 (IEC 61869-2) [1]. Linearity error ? 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature ?25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 0.5 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross power plugin connector: side contacts to stack up to 3 Integrator modules and use only one power supply. 24VDC Power Supply Meanwell HDR-15-24 Specification LEM Part Number AI-PMUL Function Integrator and True RMS Conditioner for Rogowski Coils Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 0.5% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm Mounting Din Rail Mount Integrator to Meter cable User Supplied Shielded cable 6mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet Product Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    50 pcs in stock

    $389.20
    $459.26 inclGST

  • LEM International SA Rogowski Coil ART-B22-D175, AC Measurement Rogowski Coil (coil only). 17.5cm Diameter, Class 0.5 FE-ART-B22-D175

    ART-B22-D175-SP3, AC Measurement Rogowski Coil (coil only). 17.5cm Diameter, Class 0.5, 3M Shielded Cable Connection

    14 pcs in stock

    LEM ART-B22-D175-SP3, AC Measurement Rogowski Coil (coil only). 17.5cm Diameter, Class 0.5, 3M Shielded Cable Connection Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). The patented Perfect Loop Technology dramatically reduces both the error due to the position of the measured conductor within the aperture, and the error due to the proximity of external conductors. The ART series single phase flexible rope CT from LEM. In conjunction with AI-PMUL combined integrator & signal conditioner LEM offer True RMS 0-5V, 0-10V, 0-20mA, 4-20mA outputs, or direct linear outputs 0.333V or 0.166V Included is a 17.5cm diameter rope CT, and 1.5M of twisted pair (1000V) output leads for connection to an integrator, or meter/logger with integration function. LEM coils come with 5 year warranty Features Rated insulation voltage 1000 V Cat III PD2 Accuracy Class 0.5 (IEC 61869-2) Protection degree IP67 ? 70, ? 125, ? 175, ? 300 mm sensing aperture 3 m output cable (other lengths available see page 8) Ambient temperature ?40 °C … +80 °C Very flexible and thin coil: 6.1 mm Slot for attaching the loop on the primary with a cable tie ? 2 mm hole to pass a security seal tampering An innovative patented clasp drastically reduces the positioning error near the closing Internal shield for enhanced measurement accuracy at low primary currents. Advantages Thin, flexible, and light weight solution Very low positioning error Quick, non-intrusive and easy setup A single sensor for a large current range without overload Less influenced by external fields Adaptable for a large range of cable diameters Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012 1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012 1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016 UL Specification LEM Part Number ART-B22-D175-SP3 Function AC Current Measurement Measuring Range 0 - 5,000 Amp RMS (Contact Us for Possible Replacement for wider range) Secondary Voltage (Sensitivity) 22.5mV Frequency Measuring Range 50-300kHz Operating Voltage Self Powered Accuracy 0.5% from 25 to 5000 Amp Phase Angle < 0.004 Coil Diameter (?) 17.5cm Coil Circumference 55cm Integrator to Coil Cable 3M Twisted Pair Maximum Voltage 1000V Reinforced insulation according to EN 61010-1 Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 7.4kV Overload 350,000 Amp Termination Style 2 Stripped Wires Weight 138g Factory Pack Qty 1 Certifications UL, ROHS Datasheet Product Datasheet Application Notes 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modeling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.

    14 pcs in stock

    $195.00
    $230.10 inclGST

  • Last stock! AI-PMUL + ART-B22-D175, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter-Rogowski Coil-LEM International SA-Fastron Electronics Store ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter

    ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter

    3 pcs in stock

    LEM ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number AI-PMUL + ART-B22-D125-SP3 Function Single Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.

    3 pcs in stock

    $447.00
    $527.46 inclGST

  • LEM International SA Rogowski Coil ART-B22-D300, AC Measurement Rogowski Coil (coil only). 30cm Diameter, Class 0.5 FE-ART-B22-D300 ART-B22-D300-SP4, AC Measurement Rogowski Coil (coil only). 30cm Diameter, Class 0.5, 4.5M Shielded Cable Connection

    ART-B22-D300-SP4, AC Measurement Rogowski Coil (coil only). 30cm Diameter, Class 0.5, 4.5M Shielded Cable Connection

    7 pcs in stock

    LEM ART-B22-D300-SP4, AC Measurement Rogowski Coil (coil only). 30cm Diameter, Class 0.5, 4.5M Shielded Cable Connection Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). The patented Perfect Loop Technology dramatically reduces both the error due to the position of the measured conductor within the aperture, and the error due to the proximity of external conductors. The ART series single phase flexible rope CT from LEM. In conjunction with AI-PMUL combined integrator & signal conditioner LEM offer True RMS 0-5V, 0-10V, 0-20mA, 4-20mA outputs, or direct linear outputs 0.333V or 0.166V Included is a 30cm diameter rope CT, and 1.5M of twisted pair (1000V) output leads for connection to an integrator, or meter/logger with integration function. LEM coils come with 5 year warranty Features Rated insulation voltage 1000 V Cat III PD2 Accuracy Class 0.5 (IEC 61869-2) Protection degree IP67 ⌀ 70, ⌀ 125, ⌀ 175, ⌀ 300 mm sensing aperture 3 m output cable (other lengths available see page 8) Ambient temperature −40 °C … +80 °C Very flexible and thin coil: 6.1 mm Slot for attaching the loop on the primary with a cable tie ⌀ 2 mm hole to pass a security seal tampering An innovative patented clasp drastically reduces the positioning error near the closing Internal shield for enhanced measurement accuracy at low primary currents. Advantages Thin, flexible, and light weight solution Very low positioning error Quick, non-intrusive and easy setup A single sensor for a large current range without overload Less influenced by external fields Adaptable for a large range of cable diameters Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012 1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012 1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016 UL Specification LEM Part Number ART-B22-D300-SP4 Function AC Current Measurement Measuring Range 0 - 5,000 Amp RMS (Contact Us for Possible Replacement for wider range) Secondary Voltage (Sensitivity) 22.5mV Frequency Measuring Range 50-300kHz Operating Voltage Self Powered Accuracy 0.5% from 25 to 5000 Amp Phase Angle < 0.004 Coil Diameter (⌀) 30cm Coil Circumference 95cm Integrator to Coil Cable 4.5M Twisted Pair / Coax Maximum Voltage 1000V Reinforced insulation according to EN 61010-1 Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 7.4kV Overload 300,000 Amp Termination Style 2 Stripped Wires Weight 155g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet Product Datasheet Application Notes 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modeling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    7 pcs in stock

    $215.00
    $253.70 inclGST

  • LEM International SA Rogowski Coil AI-PMUL Universal Integrator for Rogowski Coils, Multi Range Input and Output, up to 5000Amp Measurement, Din Rail Mount FE-Integrator AI-PMUL

    AI-P1A Universal Integrator for Rogowski Coils, Input (100 to 5000 Amp) and Output (0.333V,0.225), 1 Amp Output, Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount

    10 pcs in stock

    LEM AI-P1A Universal Integrator for Rogowski Coils, Multi Range Input (100 to 5000 Amp) and Output (0.333V,0.225), 1 Amp Output, Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both True RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. optional Input signal 1 Amp output for Power Quality Measurements up to the 32nd Harmonic (1600Hz) Accuracy Class 0.5 (IEC 61869-2) [1]. Linearity error ? 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature ?25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 0.5 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross power plugin connector: side contacts to stack up to 3 Integrator modules and use only one power supply. 24VDC Power Supply Meanwell HDR-30-24 Specification LEM Part Number AI-P1A Function Integrator and True RMS Conditioner for Rogowski Coils Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output 1 Amp AC Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 0.5% from 25 to 5000 Amp Current Consumption 350mA (max) Dimensions 100mm x 78mm x 15mm Mounting Din Rail Mount Integrator to Meter cable User Supplied Shielded cable 6mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet Product Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    10 pcs in stock

    $353.00
    $416.54 inclGST

  • AI-PMUL + ART-B22-D125, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter-Rogowski Coil-LEM International SA-Fastron Electronics Store ART-B22-D175-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter

    ART-B22-D175-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter

    14 pcs in stock

    LEM ART-B22-D175-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number AI-PMUL + ART-B22-D175 Function Single Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.

    14 pcs in stock

    $470.00
    $554.60 inclGST

  • Last stock! AI-P1A + ART-B22-D175, Single Phase Rogowski Coil Set, Class 0.5, User Selectable 0.333v, 0.166v, 1 Amp AC, Sensitivity, and Measurement Range, 17.5cm Diameter-Rogowski Coil-LEM International SA-Fastron Electronics Store ART-B22-D125-SP3 + AI-P1A, Single Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 12.5cm Diameter

    ART-B22-D125-SP3 + AI-P1A, Single Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 12.5cm Diameter

    3 pcs in stock

    LEM ART-B22-D125-SP3 + AI-P1A, Single Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 12.5cm Diameter The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 0.5 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 1 Amp instantaneous output. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 0.5 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D125-SP3 + AI-P1A Function Single Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output 1 Amp output Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet AI-P1A Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    3 pcs in stock

    $538.00
    $634.84 inclGST

  • LEM International SA Rogowski Coil ART-B22-D125, AC Measurement Rogowski Coils (coil only). 12.5cm Diameter, Class 0.5 FE-ART-B22-D125 ART-B22-D125-SP6, AC Measurement Rogowski Coils (coil only). 12.5cm Diameter, Class 0.5, 6M Shielded Cable Connection

    ART-B22-D125-SP6, AC Measurement Rogowski Coils (coil only). 12.5cm Diameter, Class 0.5, 6M Shielded Cable Connection

    Out of stock , More available in 16-20 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM ART-B22-D125-SP6, AC Measurement Rogowski Coils (coil only). 12.5cm Diameter, Class 0.5, 6M Shielded Cable Connection Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). The patented Perfect Loop Technology dramatically reduces both the error due to the position of the measured conductor within the aperture, and the error due to the proximity of external conductors. The ART series single phase flexible rope CT from LEM. In conjunction with AI-PMUL combined integrator & signal conditioner LEM offer True RMS 0-5V, 0-10V, 0-20mA, 4-20mA outputs, or direct linear outputs 0.333V or 0.166V Included is a 12.5cm diameter rope CT, and 1.5M of twisted pair (1000V) output leads for connection to an integrator, or meter/logger with integration function. LEM coils come with 5 year warranty Features Rated insulation voltage 1000 V Cat III PD2 Accuracy Class 0.5 (IEC 61869-2) Protection degree IP67 ⌀ 70, ⌀ 125, ⌀ 175, ⌀ 300 mm sensing aperture 3 m output cable (other lengths available see page 8) Ambient temperature −40 °C … +80 °C Very flexible and thin coil: 6.1 mm Slot for attaching the loop on the primary with a cable tie ⌀ 2 mm hole to pass a security seal tampering An innovative patented clasp drastically reduces the positioning error near the closing Internal shield for enhanced measurement accuracy at low primary currents. Advantages Thin, flexible, and light weight solution Very low positioning error Quick, non-intrusive and easy setup A single sensor for a large current range without overload Less influenced by external fields Adaptable for a large range of cable diameters Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012 1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012 1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016 UL Specification LEM Part Number ART-B22-D125-SP6 Function AC Current Measurement Measuring Range 0 - 5,000 Amp RMS (Contact Us for Possible Replacement for wider range) Secondary Voltage (Sensitivity) 22.5mV Frequency Measuring Range 50-373kHz Operating Voltage Self Powered Accuracy 0.5% from 25 to 5000 Amp Phase Angle < 0.004 Coil Diameter (⌀) 12.5cm Coil Circumference 40cm Integrator to Coil Cable 3M Twisted Pair Maximum Voltage 1000V Reinforced insulation according to EN 61010-1 Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 7.4kV Overload 300,000 Amp Termination Style 2 Stripped Wires Weight 130g Factory Pack Qty 1 Certifications UL, ROHS Datasheet Product Datasheet Application Notes 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modeling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.

    Out of stock , More available in 16-20 Weeks

    Free Aus Post Shipping for $300 Spend

    $149.00
    $175.82 inclGST

  • RCT-3600-3000 0.333V, Single Phase 3000Amp AC Measurement 12 Inch Rogowski Coil with Integrator, Class 1

    RCT-3600-3000 0.333V, Single Phase 3000Amp AC Measurement 12 Inch Rogowski Coil with Integrator, Class 1

    Out of stock , More available in 3-4 weeks

    Free Aus Post Shipping for $300 Spend

    RCT-1200 Single Phase Flexible Current Sensor System: The RCS-1200 Single Phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt. A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables. Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Magnelab Coils come with 10 year warranty Specification Magnelab Part Number RCT-3600-3000 Function AC Current Measurement Nominal Measurement Current (Ipn) 3000 Amp RMS Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 9 - 36VDC Accuracy 1% from 25 to 1000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 12 Inch Coil Circumference 36 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 1200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide

    Out of stock , More available in 3-4 weeks

    Free Aus Post Shipping for $300 Spend

    $357.00
    $421.26 inclGST

  • RCT-1200-1000 0.333V, Single Phase, 1000Amp AC Measurement, 6 Inch Rogowski Coil Integrator, Class 1

    RCT-1200-1000 0.333V, Single Phase, 1000Amp AC Measurement, 6 Inch Rogowski Coil Integrator, Class 1

    Out of stock , More available in 3-4 weeks

    Free Aus Post Shipping for $300 Spend

    RCT-1200 Single Phase Flexible Current Sensor System: The RCS-1200 Single Phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt. A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables. Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Magnelab Coils come with 10 year warranty Specification Magnelab Part Number RCT-1200-1000 Function AC Current Measurement Nominal Measurement Current (Ipn) 1000 Amp RMS Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 9 - 36VDC Accuracy 1% from 25 to 1000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 4 Inch Coil Circumference 12 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 1200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide

    Out of stock , More available in 3-4 weeks

    Free Aus Post Shipping for $300 Spend

    $335.00
    $395.30 inclGST

  • RCT-1200-3000 0.333V, Single Phase, 3000Amp AC Measurement, 6 Inch Rogowski Coil with Integrator, Class 1

    RCT-1200-3000 0.333V, Single Phase, 3000Amp AC Measurement, 6 Inch Rogowski Coil with Integrator, Class 1

    Out of stock , More available in 3-4 weeks

    Free Aus Post Shipping for $300 Spend

    RCT-1200 Single Phase Flexible Current Sensor System: The RCS-1200 Single Phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt. A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables. Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Magnelab Coils come with 10 year warranty Specification Magnelab Part Number RCT-1200-3000 Function AC Current Measurement Nominal Measurement Current (Ipn) 3000 Amp RMS Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 9 - 36VDC Accuracy 1% from 25 to 3000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 4 Inch Coil Circumference 12 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 1200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide

    Out of stock , More available in 3-4 weeks

    Free Aus Post Shipping for $300 Spend

    $335.00
    $395.30 inclGST

  • AI-PMUL + ART-B22-D300, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 30cm Diameter-Rogowski Coil-LEM International SA-Fastron Electronics Store ART-B22-D300-SP4 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 30cm Diameter

    ART-B22-D300-SP4 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 30cm Diameter

    7 pcs in stock

    LEM ART-B22-D300-SP4 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 30cm Diameter The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D300-SP4 + AI-PMUL Function Single Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 30cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 4.5M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    7 pcs in stock

    $595.00
    $702.10 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account