Schurter 3-101-144, IEC Appliance Inlet, C14/M with 1 Stage EMC (RFI) Line Filter, 15 Amp, Front Side Mounting, Plastic Flange Screw On Type
Features
Panel Mount : Screw-on or snap-in mounting from front side
2 Functions : Appliance Inlet Protection class II, Line filter in standard and medical version
Solder terminals or quick connect terminals
Characteristics
Compact high performance filter
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
Standard version without X-capacitor
Polarized C8 connector
Specification
Schurter Part Number
3-101-144
Rated Voltage
250V
Rated Current
15A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
N/A
Line Switch
N/A
Mounting
Panel Mount - Screw On
Material
Thermoplastic, black, UL 94V-0
Termination Style
C14 Male to Quick Connects
Weight
60g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Alternatives
version without line filter 2576; 2578
Schurter 5120.2207.0, IEC Appliance Inlet, C14/M with 1 Stage EMC (RFI) Line Filter, 15 Amp, Front Side Mounting, Snap On
Features
Panel Mount : Screw-on or snap-in mounting from front side
2 Functions : Appliance Inlet Protection class II, Line filter in standard and medical version
Solder terminals or quick connect terminals
Characteristics
Compact high performance filter
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
Standard version without X-capacitor
Polarized C8 connector
Specification
Schurter Part Number
5120.2207.0
Rated Voltage
250V
Rated Current
15A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
N/A
Line Switch
N/A
Mounting
Panel Mount - Screw in
Material
Thermoplastic, black, UL 94V-0
Termination Style
C14 Male to Quick Connects
Weight
60g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Alternatives
version without line filter 2576; 2578
Schurter 4302.5315 (KFB .25QC 2-P SW 10A), IEC Appliance Inlet C14/M with 1-Stage EMC (RFI), Line Switch 2 Pole
Features
Panel Mount : Screw-on mounting from front side
3 Functions : Appliance Inlet Protection class I, Line Switch 2-pole, EMC Filter 1 Stage
Line filter in standard and medical version
Quick connect terminals 6.3 x 0.8 mm
Characteristics
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
2-stage line filter with increased attenuation
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Medical Version
M80
Specification
Schurter Part Number
4302-5315 (KFB .25QC 2-P SW 10A)
Rated Voltage
250V
Rated Current
10A
Filter Stages
1 Stage Standard Attenuation
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
N/A
Line Switch
2 Pole
Mounting
Panel Mount - Case 50
Material
Nickel Plated Steel
Termination Style
C14 Male to Quick Connects
Weight
120g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter CE20.6100.151, IEC Appliance Inlet C14/M with Filter, Fuseholder 2-pole 5 x 20 mm
Features
Panel Mount : Screw-on mounting from front side
4 Functions : Appliance Inlet Protection class I, EMC Line Filter Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole
Line filter in standard and medical version
Quick connect terminals 6.3 x 0.8 mm
Characteristics
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Medical Version
M80
NOTE Requires 4305.0001,4305.0006,4305.0011,or 4305.0016 Fuse Drawer
Specification
Schurter Part Number
CE20.6100.151
Rated Voltage
250V
Rated Current
2A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
2 Pole
Line Switch
2 Pole
Mounting
Panel Mount
Material
Nickel Plated Steel
Termination Style
C14 Male to Quick Connects
Weight
260g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5008.0006, IEC Appliance Inlet C8 with 1 Stage EMC (RFI) Line Filter, Screw On
Features
Panel Mount : Screw-on or snap-in mounting from front side
2 Functions : Appliance Inlet Protection class II, Line filter in standard and medical version
Solder terminals or quick connect terminals
Characteristics
Compact high performance filter
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
Standard version without X-capacitor
Polarized C8 connector
Specification
Schurter Part Number
5008-0006
Rated Voltage
250V
Rated Current
6A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
N/A
Line Switch
N/A
Mounting
Panel Mount - Screw in
Material
Thermoplastic, black, UL 94V-0
Termination Style
C8/Faston
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Alternatives
version without line filter 2576; 2578
Schurter 4304.5029 (FKID2-50-4/M80-A), IEC Appliance Inlet C14/M with 2-Stage EMC (RFI) Line Filter
Features
Panel Mount : Screw-on mounting from front side
4 Functions : Appliance Inlet Protection class I, EMC Filter 2 Stage High Attenuation, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole
Line filter in standard and medical version
Quick connect terminals 6.3 x 0.8 mm
Characteristics
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
2-stage line filter with increased attenuation
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Medical Version
M80
Specification
Schurter Part Number
4304-5029 (FKID2-50-4/M80-A)
Rated Voltage
250V
Rated Current
4A
Filter Stages
2 Stage Higher Attenuation
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
2 Pole
Line Switch
2 Pole
Mounting
Panel Mount - Case 50
Material
Nickel Plated Steel
Termination Style
C14 Male to Quick Connects
Weight
260g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 4304.4022 (FKI2-50-2/I), IEC Appliance Inlet C14/M with 1 Stage EMC (RFI) Line Filter
Features
Panel Mount : Screw-on mounting from front side
4 Functions : Appliance Inlet Protection class I, EMC Line Filter 1 Stage, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole
Line filter in standard and medical version
Quick connect terminals 6.3 x 0.8 mm
Characteristics
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Medical Version
M80
Specification
Schurter Part Number
4304-4022 (FKI2-50-2/I)
Rated Voltage
250V
Rated Current
2A
Filter Stages
1 Stage Standard
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
2 Pole
Line Switch
2 Pole
Mounting
Panel Mount - Case 50
Material
Nickel Plated Steel
Termination Style
C14 Male to Quick Connects
Weight
260g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet