IEC Inlets with filter
-
4301.6004, IEC Appliance Inlet C14/M with 1 Stage EMC (RFI), Line Switch 2 Pole, Line Switch 2 Pole KFA Series, 6 Amp
Schurter 4301.6004, IEC Appliance Inlet C14/M with 1 Stage EMC (RFI), Line Switch 2 Pole, Line Switch 2 Pole KFA Series, 6 Amp Features Panel Mount : Screw-on mounting from front side 3 Functions : Appliance Inlet Protection class I, Line Switch 2-pole, EMC Filter 1 Stage Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement 2-stage line filter with increased attenuation With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Medical Version M80 Specification Schurter Part Number 4301.6004 (KFA Series) Rated Voltage 250V Rated Current 6A Filter Stages 1 Stage Standard Attenuation Operating Temperature -25°C to 85°C Filter Type Differential and Common Mode Fuse Holder N/A Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14 Male to Quick Connects Weight 66g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$45.80
$54.04 inclGST -
KM01.1105.11, IEC Appliance Inlet C14 with 2 Pole Switch and Fuse
Schurter KM01.1105.11, IEC Appliance Inlet C14 with 1 Stage EMC (RFI) Line Filter, Switch and Fuse Features Panel Mount : Screw-on mounting from front side 4 Functions : Appliance Inlet Protection class I, EMC Line Filter 1 Stage, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Medical Version M80 Specification Schurter Part Number KM01.1105.11 Rated Voltage 250V Rated Current 10A Filter Stages N/A Operating Temperature -25°C to 85°C Filter Type N/A Fuse Holder 2 Pole Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14/Faston Weight 30g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$39.00
$46.02 inclGST -
5008.2016, IEC Appliance Inlet C8 with 1 Stage EMC (RFI) Line Filter, Front Side Mounting, Snap In
Schurter 5008.2016, IEC Appliance Inlet C8 with 1 Stage EMC (RFI) Line Filter, Snap In Features Panel Mount : Screw-on or snap-in mounting from front side 2 Functions : Appliance Inlet Protection class II, Line filter in standard and medical version Solder terminals or quick connect terminals Characteristics Compact high performance filter Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request Standard version without X-capacitor Polarized C8 connector Specification Schurter Part Number 5008-2016 Rated Voltage 250V Rated Current 2A Filter Stages 1 Stage Standard Operating Temperature -25°C to 85°C Filter Type Differential and Common Mode Fuse Holder N/A Line Switch N/A Mounting Panel Mount - Snap in Material Thermoplastic, black, UL 94V-0 Termination Style C8/Faston Weight 40g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet Alternatives version without line filter 2576; 2578
$9.50
$11.21 inclGST -
3-107-469, DD12 IEC Appliance Inlet IEC-320 C14/M with Standard EMC (RFI) Line Filter, Quick Connect Terminals, Snap In Mounting, 2 Pole Fused
Schurter 3-107-469, DD12 IEC Appliance Inlet IEC-320 C14/M with Standard EMC (RFI) Line Filter, Quick Connect Terminals, Snap In Mounting, 2 Pole Fused Features Panel Mount : Screw-on mounting from front side 4 Functions : Appliance Inlet Protection class I, EMC Filter, Line Switch 2-pole, Fuseholder for fuse drawer 5 x 20 mm 2-pole Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement Standard line filter With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Specification Schurter Part Number 3-107-469 Rated Voltage 250V Rated Current 10A Filter Stages 1 Stage Standard Type Operating Temperature -25°C to 85°C Filter Type Standard Fuse Holder 2 Pole Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14/M to Quick Connects Weight 160g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$54.39
$64.18 inclGST -
4301.5208, IEC Inlet/Power Entry Connector Receptacle with EMC Filter, 10 Amp, Male Blades - Module IEC 320-C14 Panel Mount, Flange
Schurter 4301.5208, IEC Inlet/Power Entry Connector Receptacle with EMC Filter, 10 Amp, Male Blades - Module IEC 320-C14 Panel Mount, Flange Features Panel Mount : Screw-on mounting from front side 3 Functions : Appliance Inlet Protection class I, Line Switch 2-pole, EMC Filter 1 Stage Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement 2-stage line filter with increased attenuation With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Medical Version M80 Specification Schurter Part Number 4301.5208 Rated Voltage 250V Rated Current 6A Filter Stages 1 Stage Standard Attenuation Operating Temperature -25°C to 85°C Filter Type Differential and Common Mode Fuse Holder N/A Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14 Male to Quick Connects Weight 72g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$67.00
$79.06 inclGST -
4301.5005, IEC Inlet/Power Entry Connector Receptacle with EMC Filter, 10 Amp, Male Blades - Module IEC 320-C14 Panel Mount, Flange
Schurter 4301.5005, IEC Inlet/Power Entry Connector Receptacle with EMC Filter, 10 Amp, Male Blades - Module IEC 320-C14 Panel Mount, Flange Features Panel Mount : Screw-on mounting from front side 3 Functions : Appliance Inlet Protection class I, Line Switch 2-pole, EMC Filter 1 Stage Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement 2-stage line filter with increased attenuation With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Medical Version M80 Specification Schurter Part Number 4301.5005 (KFA Series) Rated Voltage 250V Rated Current 10A Filter Stages 1 Stage Standard Attenuation Operating Temperature -25°C to 85°C Filter Type Differential and Common Mode Fuse Holder N/A Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14 Male to Quick Connects Weight 66g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$48.30
$56.99 inclGST -
DD12.9121.111, IEC Appliance Inlet IEC-320 C14/M with Standard EMC (RFI) Line Filter, Quick Connect Terminals
Schurter DD12.9121.111, IEC Appliance Inlet IEC-320 C14/M with Standard EMC (RFI) Line Filter, Quick Connect Terminals Features Panel Mount : Screw-on mounting from front side 4 Functions : Appliance Inlet Protection class I, EMC Filter, Line Switch 2-pole, Fuseholder for fuse drawer 5 x 20 mm 2-pole Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement Standard line filter With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Specification Schurter Part Number DD12.9121.111 Rated Voltage 250V Rated Current 10A Filter Stages 2 Stage Higher Attenuation Operating Temperature -25°C to 85°C Filter Type Standard Fuse Holder 2 Pole Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14/M to Quick Connects Weight 260g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$55.00
$64.90 inclGST -
FEFAS103-D6A, IEC Appliance Inlet C14/M with 1 Stage EMC (RFI), Fuseholder 2 Pole, Line Switch 2 Pole , 6 Amp
FEFAS103-D6A, IEC Appliance Inlet C14/M with 1 Stage EMC (RFI), Fuseholder 2 Pole, Line Switch 2 Pole , 6 Amp Features Panel Mount : Screw-on mounting from front side 4 Functions : Appliance Inlet Protection class I, EMC Filter 2 Stage High Attenuation, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement 2-stage line filter with increased attenuation With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Medical Version M80 Specification Fastron Part Number FEFAS103-D6A Rated Voltage 250V Rated Current 6A Filter Stages 1 Stage Higher Attenuation Operating Temperature -25°C to 85°C Filter Type Differential and Common Mode Fuse Holder 2 Pole Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14 Male to Quick Connects Weight 260g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$49.00
$57.82 inclGST -
FEFAS103-D10A, IEC Appliance Inlet C14/M with 1 Stage EMC (RFI), Fuseholder 2.pole, Line Switch 2 Pole , 10 Amp
FEFAS103-D10A, IEC Appliance Inlet C14/M with 1 Stage EMC (RFI), Fuseholder 2.pole, Line Switch 2 Pole , 10 Amp Features Panel Mount : Screw-on mounting from front side 4 Functions : Appliance Inlet Protection class I, EMC Filter 2 Stage High Attenuation, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement 2-stage line filter with increased attenuation With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Medical Version M80 Specification Fastron Part Number FEFAS103-D10A Rated Voltage 250V Rated Current 10A Filter Stages 1 Stage Higher Attenuation Operating Temperature -25°C to 85°C Filter Type Differential and Common Mode Fuse Holder 2 Pole Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14/M to Quick Connects Weight 260g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$49.00
$57.82 inclGST -
FEFAS103-16A, IEC Appliance Inlet, C20/E with 1 Stage EMC (RFI) Line Filter, 16 Amp, Front Side Mounting, Plastic Flange Screw On Type
FEFAS103-16A, IEC Appliance Inlet, C20/E with 1 Stage EMC (RFI) Line Filter, 16 Amp, Front Side Mounting, Plastic Flange Screw On Type Features Panel Mount : Screw-on or snap-in mounting from front side 2 Functions : Appliance Inlet Protection class II, Line filter in standard and medical version Solder terminals or quick connect terminals Characteristics Compact high performance filter Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request Standard version without X-capacitor Polarized C8 connector Specification Fastron Part Number FEFAS103-15A Rated Voltage 250V Rated Current 15A Filter Stages 1 Stage Standard Operating Temperature -25°C to 85°C Filter Type Differential and Common Mode Fuse Holder N/A Line Switch N/A Mounting Panel Mount - Screw On Material Thermoplastic, black, UL 94V-0 Termination Style C20/Type E/Faston Weight 60g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet Alternatives 3-101-144
$16.50
$19.47 inclGST -
FEFAS103-15A, IEC Appliance Inlet, C14/M with 1 Stage EMC (RFI) Line Filter, 15 Amp, Front Side Mounting, Plastic Flange Screw On Type
FEFAS103-15A, IEC Appliance Inlet, C14/M with 1 Stage EMC (RFI) Line Filter, 15 Amp, Front Side Mounting, Plastic Flange Screw On Type Features Panel Mount : Screw-on or snap-in mounting from front side 2 Functions : Appliance Inlet Protection class II, Line filter in standard and medical version Solder terminals or quick connect terminals Characteristics Compact high performance filter Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request Standard version without X-capacitor Polarized C8 connector Specification Fastron Part Number FEFAS103-15A Rated Voltage 250V Rated Current 15A Filter Stages 1 Stage Standard Operating Temperature -25°C to 85°C Filter Type Differential and Common Mode Fuse Holder N/A Line Switch N/A Mounting Panel Mount - Screw On Material Thermoplastic, black, UL 94V-0 Termination Style C14/M to Quick Connects Weight 60g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet Alternatives 3-101-144
$13.60
$16.05 inclGST -
CD11.1501.151, IEC Appliance Inlet C14/M with 1.Stage EMC (RFI), Fuseholder 1.pole, Line Switch 2.pole 1 Amp
Schurter CD11.1501.151, IEC Appliance Inlet C14/M with 1.Stage EMC (RFI), Fuseholder 1.pole, Line Switch 2.pole 1 Amp Features Panel Mount : Screw-on mounting from front side 4 Functions : Appliance Inlet Protection class I, EMC Filter 1 Stage High Attenuation, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1-pole Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement 1-stage line filter with increased attenuation With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Specification Schurter Part Number CD11.1501.151 Rated Voltage 250V Rated Current 1A Filter Stages 1 Stage Higher Attenuation Operating Temperature -25°C to 85°C Filter Type Differential and Common Mode Fuse Holder 1 Pole Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14 Male to Quick Connects Weight 98g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$76.65
$90.45 inclGST