Fastron FRI 8-03/5, Under/Over Current Monitoring Relay AC 0.5 - 5 Amp, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-03/5
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.5 - 5 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
BA1-ND10-4A, DC Voltmeter, 48x24mm, 12-24VDC Aux Supply, 0-199VDC Input
3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Each unit needs just 40 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BA1-ND10-4A
Control Output 1 (Heat)
N/A
Control Output 2 (Cool)
N/A
Input
0-199.9V
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
5VDC
Termination Style
Screw
Weight
100g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
BA1Â Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Fastron FPC1-SPACER, Module Spacer for DIN Rail Mount Modular Contactors FPC1 SeriesÂ
Features
UL94V0
IP20
Specification
Fastron Part Number
FPC1-SPACER
Switching Type
Any
Approvals
CE
Coil Voltage
N/A
Load Rating
N/A
Special Feature
Module Spacer
Mounting Style
DIN Rail Mount
Load Voltage Range
N/A
Isolation
4kV
Unit Weight
40g
Factory Pack Qty
480
Â
Datasheet
Datasheet
Auxiliary Contacts Selection Guide
Rishabh CT 200/5 Class 0.5 10VA 62/30 (50), Current Transformer 200/5Amp CT, Class 0.5, 28mm Aperture or 10x30mm Busbar
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
CT 200/5 Class 0.5 10VA 62/30 (50)
Technology
AC Current Transformer
Ratio
200/5
Aperture Size
28mm or 10x30mm Busbar
VA Rating
10VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Advanced Energy Profinet Anybus Module, Comms Interface for Thyro PX or Basic Bus Module
Optional Connection for up to 8 Power Controllers with 8 Modules
For Thyro PX or Basic Bus
Communication Options :
Ethernet/IP
Profibus DPV1
Modbus RTU
Modbus TCP
DeviceNet
ProfiNET
EtherCAT
Specification
Advanced Energy Part Numbers
EthernetIP(2.000.090.015)ProfiNET(2.000.190.011)ModbusTCP(2.000.190.013)ProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)EtherCAT(2.000.190.016)
Functions
(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parametersTransfer of setpoints as float number in physical unitsControl Function of LED's
Protocols
EthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU
Weight
250g
Factory Pack Qty
1
Approvals
CE, UL
Operating Temperature
-20 ???? ??C
??
Datasheet and Guides
Product Datasheet
Setting Up Comms on Thyro A Series Controllers
Thyro Touch Software and Touch Display User Guide
Anybus Device Ethernet IP Setup Guide
LEM LTS 25-NP Closed Loop AC/DC Hall Effect Sensor
Features
Closed loop current transducer
Voltage output
3kV Isolation
Frequency bandwidth 200kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Low power consumption
Compact design for PCB mounting
Vref IN Vref OUT
Advantages
LXSR footprint compatible
Excellent accuracy
Zero insertion losses
Very good linearity
Very good dv/dt immunity
High immunity to external intereference
Current overload capability
Optimised response time
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Standards
EN 50178: 1997
UL 508: 2013
IEC 61010-1(safety)
Application Domain
Industrial
Specification
LEM Part Number
LTS 6-NP
Technology
Closed Loop Hall Effect
Aperture
ø3.2mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
25 Amp
Measurement Range
+/-19.2 Amp
Output
2.5 Vref
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.2%
Termination Style
PCB
Unit Weight
10g
Factory Packaging
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Alternatives
LXS 25-NP
Fastron Electronics GT-DV5-D-L, Signal Isolator/Conditioner, 0-36VDC input, 22-60VAC/DC aux, 4-20mA loop supply output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC Loop Supply Output
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-D-V5-D-L
Control Output
4-20mA Loop Supply
Input
0 - 36VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Crydom D2440DE, Dual Solid State Relay, Two Pole 15-32VDC Control, 2 x 40A, 24-280VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D2440DE
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
15-32VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
HVBD6AAR, Hermetic Battery Switch with Red Handle, SPST 1 x 600 Amp 1500VDC, with Auxiliary Contact, Flange Mount 70mm Wide, M10 Terminations, OHSA (LOTO)
DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute.
Features :
1 Pole Disconnect
Suitable for 1500VDC Battery/Solar Isolation
Standards :
OSHA (LOTO)
IP65 (Front) IP20 (Terminals)
CE Approved
Specification
Rincon Power Part Number
HVBD6AAR
Functions
1 Pole DC SPST Disconnect Switch, ON/OFF Red Handle
Nominal Voltage
1500VDC (5375VDC 1 min)
Nominal Current
1 x 600 Amp DC
Auxilairy Contact
3 Amp @ 12VDC 100k Cycles
Rated Impulse Voltage
5kV (1 min)
Rated Insulation Voltage
1500VDC
Short Circuit Current
2kA (1 min)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
120 x 84.3mm
Termination
M10 Stud
Mounting
100mm
Standards
OSHA, CE
Weight
425g
Enclosure Material
PA GF
Factory Pack Qty
15
Â
Datasheet
Product Datasheet
Rincon Power Product Portfolio
Gigavac RXC35P9QA, Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, Exceeds IP69
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
Exceeds IP69
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
RXC35P9QA
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
1000VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Iskra IK40-40-24VAC/DC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 40 Amp, 230VAC/220VDC 40-500Hz Control Voltage, Hum Free
Features
40 Amp (rms) @ 440VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IK40-40-24VAC/DC
Switching Type
4 x SPST NO
Approvals
CE
Coil Voltage
24VAC/DC 40-500Hz
Load Current (RMS/DC)
40 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC 40-500Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet