Recommended products

4104 products

  • Last stock! SCT-F50-800-100mA, 100mAmp, 800Amp Measurement Split Core CT's SCT-F50-800-100mA, 100mAmp, 800Amp Measurement Split Core CT's

    SCT-F50-800-100mA, 100mAmp, 800Amp Measurement Split Core CT's

    3 pcs in stock

    Fastron Electronics SCT-F50-800-100mA, 100mAmp, 800Amp Measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-800-100mA Technology Split Core AC Current Transformer Ratio 800/100mAmp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 800Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    3 pcs in stock

    $110.55
    $130.45 inclGST

  • Last stock! SCT-F24-125A/100mA, 125A/100mA Measurement, Class 1 Split Core CT's SCT-F24-125A/100mA, 125A/100mA Measurement, Class 1 Split Core CT's

    SCT-F24-125A/100mA, 125A/100mA Measurement, Class 1 Split Core CT's

    3 pcs in stock

    Fastron Electronics SCT-F24-125A/100mA, 125A/100mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 100mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements   Specification Fastron Part Number SCT-F24-125A/100mA Technology Split Core AC Current Transformer Ratio 125/100mA Aperture Size ø 24 mm VA Rating 1VA Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 125Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide

    3 pcs in stock

    $48.00
    $56.64 inclGST

  • CTB 35 Series Core balanced CT's for Earth Leakage Detection, Various Sizes Selectable-Solid Core AC Current Transformer-Hobut-Fastron Electronics Store

    CTB 35, 35mm Diameter CTB Series Core Balanced/Toroid CT (CBCT) for AC Earth Leakage Detection, for RCR Series Hobut Core balanced CT’s

    54 pcs in stock

    Hobut CTB 35, 35Amp Measurement Core Balanced/Toroid CT's (CBCT) for AC Earth Leakage Detection Features Very low differential current measurement Applications Earth Leakage   Specification Hobut Part Number CTB 35 Technology Core Balanced/Toroid  (CBCT)  Aperture Size 35mm Sizes Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide

    54 pcs in stock

    $50.50
    $59.59 inclGST

  • FIR-1620-24VDC, Two Pole 2 x SPST NO Bistable Relay with Manual Override 240VAC, 16 Amp, 24VDC / 48VAC Coil Voltage, 50/60Hz

    FIR-1620-24VDC, Two Pole 2 x SPST NO Bistable Relay with Manual Override 240VAC, 16 Amp, 24VDC / 48VAC Coil Voltage, 50/60Hz

    117 pcs in stock

    Fastron FIR-16-20M-24VDC / 48VAC, Two Pole 2 x SPST NO Bistable Relay 240VAC, 16 Amp, 24VDC / 48VAC Control Voltage, 50/60Hz Features 16 Amp (rms) @ 240VAC DIN Rail Mount Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number FIR-16-20M-24VDC / 48VAC Switching Type 2 x SPST NO Approvals CE Coil Voltage 24VDC / 48VAC Load Rating 16 Amp Special Feature Mounting Style DIN Rail Mount Load Voltage Range 240VAC 50/60Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20   Datasheet Datasheet

    117 pcs in stock

    $33.60
    $39.65 inclGST

  • Fastron Electronics Temperature Sensor 85 Deg C Thermal Switch, Flange Mount FE-85 Deg C Thermal Switch

    TSSNO-145, 145 Deg C,NO Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, M4 Stud Mount, Brass

    90 pcs in stock

    145 Deg C Normally Open, Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, M4 Stud Mount, Brass, KSD301, R20 Datasheet Product Datasheet

    90 pcs in stock

    $10.50
    $12.39 inclGST

  • SCT-F50-200, 0.333V, 200Amp measurement Split Core CT's SCT-F50-200, 0.333V, 200Amp measurement Split Core CT's

    SCT-F50-200, 0.333V, 200Amp measurement Split Core CT's

    27 pcs in stock

    Fastron Electronics SCT-F50-200, 0.333V, 200Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-200 Technology Split Core AC Current Transformer Ratio 200/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 200g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    27 pcs in stock

    $110.55
    $130.45 inclGST

  • PCM 10-P, Pointsenz Railway DC Current Sensor, 10 Amp, Bipolar 4-20mA Output

    PCM 10-P, Pointsenz Railway DC Current Sensor, 10 Amp, Bipolar 4-20mA Output

    10 pcs in stock

    LEM PCM 10-P Series Closed Loop DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 10-P Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 10 Amp Measuring Range +/- 20 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C (50°C Continuous) Accuracy 0.5% Termination Style Switchcraft EN3L4M connector Unit Weight 120g Factory Pack Qty 4   Datasheet Product Datasheet Application Notes FAQ

    10 pcs in stock

    $775.00
    $914.50 inclGST

  • FGR-D 2353, Thermal Overload Relay 23-32 Amp range for FGC1-D & FGP1-D Series Contactors FGR-D 2353, Thermal Overload Relay 23-32 Amp range for FGC1-D & FGP1-D Series Contactors

    FGR-D 2353, Thermal Overload Relay 23-32 Amp range for FGC1-D & FGP1-D Series Contactors

    59 pcs in stock

    FGR-D 2353, Thermal Overload Relay 23-32 Amp range for FGC1-D & FGP1-D Series Contactors Features Snap on 2 x NO, 2 x NC 6 Amp Contacts 150 grams Datasheet Thermal Relays Datasheet

    59 pcs in stock

    $23.00
    $27.14 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 50mA output, 12kV Isolation FE-DVM 2000

    DVM 2000-UI Digital Voltage Transducer, Vpn = 2000V, 24VDC Supply, 4-20mA Analogue Output, 12kV Isolation

    15 pcs in stock

    EM DVM 2000-UI Digital Voltage Transducer, Vpn = 2000V, 24VDC Supply, 4-20mA Analogue Output, 12kV Isolation Features Bandwidth DC to 13kHz 4-20mA Unipolar Analogue Output Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVM 2000-UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage 24 VDC, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 4 mA at 0V, to 20mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    15 pcs in stock

    $1,238.00
    $1,460.84 inclGST

  • BM2R08MV1 Syr-Line Multifunction Timer, 2 x 8A CO (DPDT) 0.5s - 10 Days, 12 - 240VAC/DC

    BM2R08MV1 Syr-Line Multifunction Timer, 2 x 8A CO (DPDT) 0.5s - 10 Days, 12 - 240VAC/DC

    23 pcs in stock

    Crouzet BM2R08MV1 Syr-Line Single Pole Multifunction Timer With DPDT CO Contacts BM1R Timers Syrline 17.5 mm - 2 Relays 8A : Multi-function (12 functions) Multi-range (0.5s - 10days) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input 3-wire PNP sensor compatible Multifunction Timers Includes The Following : Function A Delay on energisation 1 relay Function Ac Timing after closing and opening of control contact 1 relay Function At Timing on energisation with memory 1 relay Function B Timing on impulse one shot 1 relay Function C Timing after impulse 1 relay Function D Flip-flop Pause start 1 relay Function Di Flip-flop Pulse start 1 relay Function H Timing on energisation 1 relay Function Ht Delay on energisation with memory 1 relay Function N Watchdog Function Tl Timed impulse relay Function TL Impulse relay Specification Crouzet Part Number BM2R08MV1 (Syr-Line Timer Double Pole Multifunction, 12 - 240VAC/DC, 17.5 mm) Function Multifunction Timer A - Ac - At - B - C - D - Di - H - Ht -N - TL - Tt Nominal Voltage 12 → 240 V AC/DC Digital Output 2 x C/O (DPDT) (Changeover -Single Pole Double Throw-), 250VAC/DC @ 8 Amp R1 = Follows Timing, R2 = Instantaneous Min Breaking Current 10mA/12VDC Timing Ranges Selectable 0.5→10s, 0.05→1min, 0.5→10min, 0.05→1h, 0.5→10h, 0.05→1day, 0.5→10days Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Certification CE, cULus,CCC, ROHS, Reach, WEEE Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet

    23 pcs in stock

    $165.00
    $194.70 inclGST

  • HAX 850-S, O/L Current Transducer, 850 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    HAX 850-S, O/L Current Transducer, 850 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    17 pcs in stock

    LEM HAX 850-S Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 25kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 2500 A in one package. Up to 5500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAX 850-S Technology Open Loop Hall Effect Aperture 64 x 21mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 850 Amp Measurement Range +/-2550 Amp Overload Rating +/-30000 At Output +/-4 V Isolation 4.4 kV Bandwidth DC-25 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 450g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    17 pcs in stock

    $194.00
    $228.92 inclGST

  • SCT-F50-500, 0.333V, 500Amp measurement Split Core CT's SCT-F50-500, 0.333V, 500Amp measurement Split Core CT's

    SCT-F50-500, 0.333V, 500Amp measurement Split Core CT's

    59 pcs in stock

    Fastron Electronics SCT-F50-500, 0.333V, 500Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-500 Technology Split Core AC Current Transformer Ratio 500/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 500g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    59 pcs in stock

    $110.55
    $130.45 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account