Recommended products

4104 products

  • Sale -67% FKT91/14F Dual Thyristor Module, 90 Amp, 1400V

    FKT91/14F Dual Thyristor Module, 90 Amp, 1400V

    24 pcs in stock

    Dual Thyristor Module, 90 Amp, 1400V, 22mm Package Name Brand replacement to VSKT5614 , Obsolete.

    24 pcs in stock

    $45.00  $15.00
    $17.70 inclGST

  • 300UR120D, Rectifier Diode, 300 Amp, 1200V, 3/4 UNF-2A, Anode to stud

    300UR120D, Rectifier Diode, 300 Amp, 1200V, 3/4 UNF-2A, Anode to stud

    29 pcs in stock

    International Rectifier 300UR120D, Rectifier Diode, 300 Amp, 1200V, 3/4 UNF-2A, Anode to stud Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification International Rectifier Part Number 300UR120D Vrrm 1200V Diode Configuration Anode Stud IF(av) @ 100 Deg C 400 Amp IF(av) @ 150 Deg C 300 Amp Itsm 6.55 kA VF(to) 0.61V Tj(max) 200°C rF 0.751mΩ Termination Style (Tail) 8.3mm Round Lug Termination Style (Stud) 3/4" UNF Tail Length to Stud 149mm R th(j-c) 0.18°C/W R th(c-h) 0.08°C/W Weight 250g Mounting Torque 26 Nm Factory Pack Qty 8 Datasheet Product Datasheet

    29 pcs in stock

    $48.00
    $56.64 inclGST

  • 300U120D, Rectifier Diode, 300 Amp, 1200V, 3/4 UNF-2A, Cathode to stud

    300U120D, Rectifier Diode, 300 Amp, 1200V, 3/4 UNF-2A, Cathode to stud

    32 pcs in stock

    International Rectifier 300U120D, Rectifier Diode, 300 Amp, 1200V, 3/4 UNF-2A, Cathode to stud Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification International Rectifier Part Number 300U120D Vrrm 1200V Diode Configuration Cathode Stud IF(av) @ 100 Deg C 400 Amp IF(av) @ 150 Deg C 300 Amp Itsm 6.55 kA VF(to) 0.61V Tj(max) 200°C rF 0.751mΩ Termination Style (Tail) 8.3mm Round Lug Termination Style (Stud) 3/4" UNF Tail Length to Stud 149mm R th(j-c) 0.18°C/W R th(c-h) 0.08°C/W Weight 250g Mounting Torque 26 Nm Factory Pack Qty 8 Datasheet Product Datasheet

    32 pcs in stock

    $48.00
    $56.64 inclGST

  • Last stock! BSM50GB60DLC, IGBT Dual, 50Amp, 600V-IGBT-Infineon Technologies-Fastron Electronics Store

    BSM50GB60DLC, IGBT Dual, 50Amp, 600V

    1 pcs in stock

    Infineon BSM50GB60DLC IGBT Dual Module Features IGBT for Low Frequency Inverter Pressure Contact Technology Electrically insulated base plate Industrial standard package Medium Switching Speed 2500V Isolation 34mm Base Width Applications Frequency Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Softstart AC motor control Low Frequency Inverter Drives Specification Infineon Part Number BSM50GB60DLC Vces 600V Transistor Configuration Dual IGBT Module (Half Bridge) Ic(nom) @ 80 Deg C 50 Amp Package Size W:34mm L:94mm D:30mm V(isol) 2.5 kV Vf @ 25 Deg C 1.8 - 2.3V Tj(max) 150°C Td(on) @ 25 Deg C 0.05uS Td(off) @ 25 Deg C 0.3uS I(ces) @ 25 Deg C 500uA Rcc 1.0mOhm Terminals M5 Screw Hole Centres 80mm(M6) Gate Terminals Spade (A 2.8 - 0.5mm) R th(j-c) 0.3°C/W R th(c-h) 0.3°C/W Weight 250g Mounting Torque 5 Nm (4 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Infineon Headquarters Germany   Datasheet Product Datasheet Alternatives Contact Us for Possible Replacement for alternative

    1 pcs in stock

    $49.00
    $57.82 inclGST

  • S12AR55U, Rectifier Diode 55 Amp, 1200V, 1/4" 28UNF 2A, Anode stud

    S12AR55U, Rectifier Diode 55 Amp, 1200V, 1/4" 28UNF 2A, Anode stud

    15 pcs in stock

    Rectifier Diode 55 Amp, 1200V, 1/4" 28UNF 2A, Anode stud Product datasheet

    15 pcs in stock

    $12.90
    $15.22 inclGST

  • Last stock! MSZP26N16U, Rectifier Diode 26 Amp, 1600V, 10/32" UNF, Cathode stud

    MSZP26N16U, Rectifier Diode 26 Amp, 1600V, 10/32" UNF, Cathode stud

    1 pcs in stock

    MS Power MSZP26N16U Series Stud Mount Rectifier Diode Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification MS Power Part Number MSZP26N16U Vrrm 1600V Diode Configuration Cathode Stud IF(av) @ 100 Deg C 39 Amp IF(av) @ 125 Deg C 25 Amp Itsm 375 Amp VF(to) 0.85V Tj(max) 180°C rF 10mΩ Termination Style (No Tail) 2.2mm Solder Tab Termination Style (Stud) 10 - 32 UNF Tail Length to Stud N/A R th(j-c) 1.5°C/W R th(c-h) 0.25°C/W Weight 5.5g Mounting Torque 2 Nm Factory Pack Qty 50 Country Of Origin China MS Power Headquarters Germany Datasheet Product Datasheet Obsolescence This part is, Obsolete due to part number change see MSD26N16UB for replacement

    1 pcs in stock

    $9.00
    $10.62 inclGST

  • KS300, Plastic IP cover for Crydom 3 phase SSR

    KS300, Plastic IP cover for Crydom 3 phase SSR

    151 pcs in stock

    KS300 Plastic IP cover for Crydom brand 3 phase SSR Product Datasheet

    151 pcs in stock

    $13.61
    $16.06 inclGST

  • EZ240D5R, Solid State Relay, 4-15VDC control, 5A, 24-280VAC Load, Random Crossing, Faston

    EZ240D5R, Solid State Relay, 4-15VDC control, 5A, 24-280VAC Load, Random Crossing, Faston

    7 pcs in stock

    Crydom EZ240D5R, Solid State Relay, 4-15VDC control, 5A, 24-280VAC Load, Random Crossing, Faston Features Ratings from 5A to 18 Amp @ 600 VAC Faston terminals for easy installation SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number EZ240D5R Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 4-15VDC Load Current 5 Amp (rms) Surge Capability 40 Amp (peak) Special Feature Faston terminals Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Faston Unit Weight 43g Factory Pack Qty 20   Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies

    7 pcs in stock

    $40.70
    $48.03 inclGST

  • FRC-10-B10, AC Current Transducer, 10 Amp average RMS measurement, 0-10VDC output, 2% Accuracy, Panel Mount-Solid Core AC Current Transformer with Process Output-Fastron Electronics-Fastron Electronics Store FRC-10-B10, AC Current Transducer, 10 Amp average RMS measurement, 0-10VDC output, 2% Accuracy, 14mm Aperture, or 3.5 x 15.5mm busbar, Self Powered, Panel Mount

    FRC-10-B10, AC Current Transducer, 10 Amp average RMS measurement, 0-10VDC output, 2% Accuracy, 14mm Aperture, or 3.5 x 15.5mm busbar, Self Powered, Panel Mount

    40 pcs in stock

    FRC-10-B10, AC Current Transducer, 10 Amp average RMS measurement, 0-10VDC output, 2% Accuracy, 14mm Aperture, or 3.5 x 15.5mm busbar, Self Powered, Panel Mount Compact and low cost olid Core AC current sensor, selectable 10 Amp Average RMS 0-10 V output Features Solid Core Average RMS output 0-10V voltage output Self Powered Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀14mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will nto drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number FRC-10-B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (RMS + DC) 10 Amp Maximum Measurement Current (Peak) 12 Amp Output 0-10V Average RMS Aperture ⌀14mm, or 3.5 x 15.5mm busbar Isolation 6kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex Unit Weight 65g Factory Pack Qty 6   Datasheet Product Datasheet

    40 pcs in stock

    $89.00
    $105.02 inclGST

  • V75E40, Varistor, 75VAC, 100VDC, E40 Package 720W, Equivalent to Epcos SIOV-B40K75 Features V75E40, Varistor, 75VAC, 100VDC, E40 Package 720W, Equivalent to Epcos SIOV-B40K75 Features

    V75E40, Varistor, 75VAC, 100VDC, E40 Package 720W, Equivalent to Epcos SIOV-B40K75 Features

    42 pcs in stock

    Varsi-Raycap V75E40, 75VAC, 100VDC, E40 Package 720W Series Metal Oxide Varistor (MOV), Equivalent to Epcos SIOV-B40K75 Features High Energy Absorption Rating Industry Standard Package Wide Operating Range 35 - 1100VAC High Peak Current Capability (70kA) UL/CSA/ROHS/ISO9001:2015 Approved Panel Mount Screw Terminals APPLICATION AREAS: 1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems). 2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes. 3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules. Specification Varsi-Raycap Part Number V75E40 Operating Voltage AC (50-60Hz) 75V Operating Voltage DC 100V Average Power Dissipation 1.4W Permissable Peak Current 40kA Energy Absorption(2ms) 720W(max) Tolerance(Vn) +/- 10% Termination Style Screw Weight 65g Factory Pack Qty 1 ROHS Yes UL Yes CSA Yes   Datasheet Product Datasheet Application Notes Technical Blog MOV Article GDT/MOV/TVS Tester SPD Tester

    42 pcs in stock

    $42.00
    $49.56 inclGST

  • V420K20, Varistor, 420VAC, 560VDC, K20 Package

    V420K20, Varistor, 420VAC, 560VDC, K20 Package

    2874 pcs in stock

    Varsi V460K20 Series Metal Oxide Varistor (MOV), 420VAC, 560VDC, K20 Package High Energy Absorption Rating Industry Standard Package Wide Operating Range 35 - 1100VAC High Peak Current Capability (70kA) UL/CSA/ROHS/ISO9001:2015 Approved Panel Mount Screw Terminals APPLICATION AREAS: 1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems). 2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes. 3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules. Specification Varsi Part Number V460K20 Operating Voltage AC (50-60Hz) 460V Operating Voltage DC 560V Average Power Dissipation 1W Permissable Peak Current 5.5kA Energy Absorption(2ms) 287W(max) Tolerance(Vn) +/- 10% Termination Style Axial Lead Weight 7g Factory Pack Qty 1 ROHS Yes UL Yes CSA Yes Datasheet Product Datasheet Application Notes Technical Blog MOV Article

    2874 pcs in stock

    $0.65
    $0.77 inclGST

  • V275K10, Varistor, 275VAC, 350VDC, K10 Axial Package 50W

    V275K10, Varistor, 275VAC, 350VDC, K10 Axial Package 50W

    98 pcs in stock

    Varsi V275K10 Series Metal Oxide Varistor (MOV), 275VAC, 350VDC, K10 Axial Package 50W High Energy Absorption Rating Industry Standard Package Wide Operating Range 35 - 1100VAC High Peak Current Capability (70kA) UL/CSA/ROHS/ISO9001:2015 Approved Panel Mount Screw Terminals APPLICATION AREAS: 1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems). 2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes. 3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules. Specification Varsi Part Number V275K10 Operating Voltage AC (50-60Hz) 275V Operating Voltage DC 350V Average Power Dissipation 0.6W Permissable Peak Current 5.5kA Energy Absorption(2ms) 30W(max) Tolerance(Vn) +/- 10% Termination Style Axial Lead Weight 7g Factory Pack Qty 1 ROHS Yes UL Yes CSA Yes Datasheet Product Datasheet Application Notes Technical Blog MOV Article

    98 pcs in stock

    $0.60
    $0.71 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account