LEM LT 1005-T Open Loop AC/DC Hall Effect Sensor
Features
Bipolar and insulated current measurement up tp 2000 Amp
Current output
Bandwidth DC to 150kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 1005-T
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
1000 Amp
Measurement Range
+/- 2000 Amp
Output
200 mA
Isolation
6 kV
Bandwidth
DC-150 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.4%
Termination Style
M4 theaded studs
Unit Weight
1.27kg
Factory Pack Quantity
2
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM DHR 200 C10, Hall Effect Current Sensor, 200Amp RMS ,10V output, 32mm aperture
Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz
Features
VFD and SCR waveforms current measurement
True RMS output
4-20mA current output
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀32mm
High isolation between primary and secondary circuits
Easy installation
Applications
-VFD Controlled Loads
VFD output indicates how the motor and attached load are operating
-SCR Controlled Loads
Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement
-Application Domain
Energy and Automation
Specification
LEM Part Number
DHR 200 C10
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
20 - 50V
Load Current (RMS + DC)
200 Amp
Output
0-10V
Isolation
4kV (AC, 50Hz, 1 min)
Bandwidth
20-6000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
Level 3
Termination Style
SFKC 2.5/4-ST-5.08-RF(Phoenix Contact)
Unit Weight
260g
Factory Pack Qty
6
Datasheet
Product Datasheet
GMTA-DV7-A-RN, DC Voltage Transducer with Alarm, 0-600VDC Input, 100-240VAC/DC Aux, 1 x Relay Alarm
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint.
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Part Number
GMTA-DV7-A-RN
Control Output
1 x SPST Alarms 3 Amp
Input
0-600VDC
Alarm Type
1 x SPST NO Relay 3 Amp
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron DTC1-A/M1, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, 4-20mA output
Optional converter function
2 Input 1 Output, and 1 Input Two Output Versions available
Optional 60 Segment Multi Pattern Program Control feature
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response)
CE Approved
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Various specials available for unique applications.
Specification
Fastron Part Number
DTC1-A/M1
Control Output
4-20mA
Input
Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100
Alarm
Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC
Options
None
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
24VAC/DC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
CE
Yes
??
Selection Chart
PWM Control Wiring
Datasheet
DTC1 Brochure
DTC1User Manual
DTC1 User Manual Comms versions
Alarm Table
DTC1 (Program Control Version) User Manual
Fastron DTC1-R/M1, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, Relay output
Optional converter function
2 Input 1 Output, and 1 Input Two Output Versions available
Optional 60 Segment Multi Pattern Program Control feature
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response)
CE Approved
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Various specials available for unique applications.
Specification
Fastron Part Number
DTC1-R/M1
Control Output
Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC
Input
Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100
Alarm
Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC
Options
None
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
24VAC/DC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
CE
Yes
??
Selection Chart
PWM Control Wiring
Datasheet
DTC1 Brochure
DTC1User Manual
DTC1 User Manual Comms versions
Alarm Table
DTC1 (Program Control Version) User Manual
Semikron SKKT27B12E, Dual Thyristor Module, 27 Amp, 1200V, With Aux Cathode Connection
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Semikorn Part Number
SKKT27B12E
Vrrm
1200V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
27 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Faston A2.8 x 0.8mm
Weight
110g
Mounting Torque
5 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
Hungary
Datasheet
Datasheet
Alternatives
See MCC16-16io1b for IXYS alternative
Fastron F157FT-1PL 12A 240VAC Series SPDT 12 Amp Form C,??Socket or PCB Mount AC/DC Relay, 240F157FT-1PL 12A 230VAC Coil
Features
1 x SPDT 12 Amp @ 250VAC or 30VDC
Socket or PCB Mount
Changeover Contact
Slim package
UL Approved
Compatible with Omron G2R-1-S Series
CE Compliant to IEC 60664
IP20
Suits F157F-1Z-C3 socket
Specification
Fastron Part Number
F157FT-1PL 12A 240VAC
Switching Type
1 x SPDT 30VDC/250VAC C/O??Form C
Approvals
UL, CE
Coil Voltage
240VAC
Load Current
1 x 12 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
PCB or Socket Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
35g
Factory Pack Qty
20
??
Datasheet
Relay Datasheet
Socket Replacement
F157F-1Z-C3
Relay Replacement
F157FT-1PL 12A 240VAC
Iskra Doo K03M-01-240V, AC Miniature Contactor 240/400/500/690V, with 240VAC Control Voltage, 4 Pole 3 x NO, 1 x NC, Nominal Current = 8.5 Amps
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
K03M-01-240V
Functions
4 Pole Contactor 3 x NO, 1 x NC
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
8.5 Amp Continuous @ 55 Deg C
Auxiliary Contacts
Optional Snap on
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
0.36W
Approvals
UL, CSA, CE
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
CV 3-200/SP5 Voltage Transducer Flux Gate, Vpn = 140V RMS, 10V output, +/- 15/24VDC supply, 2.5kV Isolation
Features
Bandwidth DC to 700kHz
Closed loop transducer using Flux Gate
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
High Frequency Drives
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
CV 3-200/SP5
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 140V
Measurement Range
+/- 200V
Output
10V @Vp(max)
Isolation
2.5 kV
Bandwidth
DC-700 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 75°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
650g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition