Recommended products

4098 products

  • LT 1005-T C/L Hall Effect Current Sensor, Ipn = 1000 Amp, Isn = 200mA, +/-24VDC Supply, Busbar, X = 0.4%, panel mount

    LT 1005-T C/L Hall Effect Current Sensor, Ipn = 1000 Amp, Isn = 200mA, +/-24VDC Supply, Busbar, X = 0.4%, panel mount

    48 pcs in stock

    LEM LT 1005-T Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 2000 Amp Current output Bandwidth DC to 150kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 1005-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 2000 Amp Output 200 mA Isolation 6 kV Bandwidth DC-150 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style M4 theaded studs Unit Weight 1.27kg Factory Pack Quantity 2 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    48 pcs in stock

    $859.10
    $1,013.74 inclGST

  • DHR 200 C10, Hall Effect Current Sensor, 200Amp RMS ,10V output, 32mm aperture

    DHR 200 C10, Hall Effect Current Sensor, 200Amp RMS ,10V output, 32mm aperture

    48 pcs in stock

    LEM DHR 200 C10, Hall Effect Current Sensor, 200Amp RMS ,10V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 200 C10 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 200 Amp Output 0-10V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6   Datasheet Product Datasheet

    48 pcs in stock

    $520.00
    $613.60 inclGST

  • Last stock! GMTA-DV7-A-RN, DC Voltage Transducer with Alarm, 0-600VDC Input, 100-240VAC/DC Aux, 1 x Relay Alarm

    GMTA-DV7-A-RN, DC Voltage Transducer with Alarm, 0-600VDC Input, 100-240VAC/DC Aux, 1 x Relay Alarm

    1 pcs in stock

    GMTA-DV7-A-RN, DC Voltage Transducer with Alarm, 0-600VDC Input, 100-240VAC/DC Aux, 1 x Relay Alarm Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint. Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Part Number GMTA-DV7-A-RN Control Output 1 x SPST Alarms 3 Amp Input 0-600VDC Alarm Type 1 x SPST NO Relay 3 Amp Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    1 pcs in stock

    $309.00
    $364.62 inclGST

  • Last stock! 1 2

    DTC1-A/M1, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, 4-20mA output

    5 pcs in stock

    Fastron DTC1-A/M1, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, 4-20mA output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M1 Control Output 4-20mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual

    5 pcs in stock

    $192.00
    $226.56 inclGST

  • 1 2

    DTC1-R/M1, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, Relay output

    9 pcs in stock

    Fastron DTC1-R/M1, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, Relay output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-R/M1 Control Output Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual

    9 pcs in stock

    $189.00
    $223.02 inclGST

  • SKKT27B12E, Dual Thyristor Module, 27 Amp, 1200V, With Aux Cathode Connection SKKT27B12E, Dual Thyristor Module, 27 Amp, 1200V, With Aux Cathode Connection

    SKKT27B12E, Dual Thyristor Module, 27 Amp, 1200V, With Aux Cathode Connection

    12 pcs in stock

    Semikron SKKT27B12E, Dual Thyristor Module, 27 Amp, 1200V, With Aux Cathode Connection Features Thyristor for line frequency Solder - Solder Bonded Electrically insulated base plate Industrial standard package 3600V Isolation 22mm Base Width Applications Power Converter Line rectifying 50/60 Hz Controlled Rectifiers Softstart AC motor control AC power control Lighting and temperature control Specification Semikorn Part Number SKKT27B12E Vrrm 1200V Diode Configuration Dual Thyristor Module IF(av) @ 85 Deg C 27 Amp Package Size W:22mm L:93mm D:30mm TO-240AA Terminals M5 Screw Hole Centres 80mm (M6) Gate Terminals Faston A2.8 x 0.8mm Weight 110g Mounting Torque 5 Nm (3 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Country of Origin Hungary   Datasheet Datasheet Alternatives See MCC16-16io1b for IXYS alternative  

    12 pcs in stock

    $55.49
    $65.48 inclGST

  • F157FT-1PL 12A 240VAC, Relay, 1 x SPDT 12 Amp, 250VAC/30VDC Load, 240VAC Coil, Socket or PCB Mount-Relay-Fastron Electronics-Fastron Electronics Store Relequick Relay RQS10L024DC0T, Relay, SPDT 1 x 16 Amp, 250VAC/30VDC Load, 24VDC Coil FE-RQS10L024DC0T

    F157FT-1PL 12A 240VAC, Relay, 1 x SPDT 12 Amp Form C, 250VAC/30VDC Load, 240VAC Coil, Socket or PCB Mount

    264 pcs in stock

    Fastron F157FT-1PL 12A 240VAC Series SPDT 12 Amp Form C,??Socket or PCB Mount AC/DC Relay, 240F157FT-1PL 12A 230VAC Coil Features 1 x SPDT 12 Amp @ 250VAC or 30VDC Socket or PCB Mount Changeover Contact Slim package UL Approved Compatible with Omron G2R-1-S Series CE Compliant to IEC 60664 IP20 Suits F157F-1Z-C3 socket Specification Fastron Part Number F157FT-1PL 12A 240VAC Switching Type 1 x SPDT 30VDC/250VAC C/O??Form C Approvals UL, CE Coil Voltage 240VAC Load Current 1 x 12 Amp (rms) Special Feature LED Status Indicator Mounting Style PCB or Socket Mount Load Voltage Range 0-250VAC, 0-30VDC Isolation 2.5kV Termination Style PCB or Socket Mount Unit Weight 35g Factory Pack Qty 20 ?? Datasheet Relay Datasheet Socket Replacement F157F-1Z-C3 Relay Replacement F157FT-1PL 12A 240VAC

    264 pcs in stock

    $10.00
    $11.80 inclGST

  • K03M-10-240V AC Miniature Contactor 240/400/500/690V, with 240VAC Control Voltage, 4 Pole 4 x NO, Nominal Current = 15.5 Amps-Miniature AC Contactor-Iskra Doo-Fastron Electronics Store

    K03M-01-240V, AC Miniature Contactor 240/400/500/690V, with 240VAC Control Voltage, 4 Pole 3 x NO, 1 x NC, Nominal Current = 8.5 Amps

    8 pcs in stock

    Iskra Doo K03M-01-240V, AC Miniature Contactor 240/400/500/690V, with 240VAC Control Voltage, 4 Pole 3 x NO, 1 x NC, Nominal Current = 8.5 Amps Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number K03M-01-240V Functions 4 Pole Contactor 3 x NO, 1 x NC Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 8.5 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional Snap on Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 0.36W Approvals UL, CSA, CE Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 200g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue

    8 pcs in stock

    $56.00
    $66.08 inclGST

  • CV 3-200/SP5, Voltage Transducer Flux Gate, Vpn = 140V RMS, 10V output, +/- 15/24VDC supply, 2.5kV Isolation

    CV 3-200/SP5, Voltage Transducer Flux Gate, Vpn = 140V RMS, 10V output, +/- 15/24VDC supply, 2.5kV Isolation

    10 pcs in stock

    CV 3-200/SP5 Voltage Transducer Flux Gate, Vpn = 140V RMS, 10V output, +/- 15/24VDC supply, 2.5kV Isolation Features Bandwidth DC to 700kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 3-200/SP5 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 140V Measurement Range +/- 200V Output 10V @Vp(max) Isolation 2.5 kV Bandwidth DC-700 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    10 pcs in stock

    $1,698.00
    $2,003.64 inclGST

  • SM-30-M8, Isolated Standoff 30mm x M8

    SM-30-M8, Isolated Standoff 30mm x M8

    26 pcs in stock

    SM-30-M8, Isolated Standoff 30mm x M8 Product Datasheet

    26 pcs in stock

    $7.50
    $8.85 inclGST

  • SM-30-M8 Kit, 2pcs of Isolated Standoff 25mm x M8

    SM-30-M8 Kit, 2pcs of Isolated Standoff 25mm x M8

    13 pcs in stock

    2pcs of Isolated Standoff 25mm x M8 Product Datasheet

    13 pcs in stock

    $13.00
    $15.34 inclGST

  • SM-30-M8, Isolated standoff 30mm x M6

    SM-30-M8, Isolated standoff 30mm x M6

    26 pcs in stock

    Isolated Standoff 30mm x M6 Product Datasheet

    26 pcs in stock

    $7.00
    $8.26 inclGST

Login

Forgot your password?

Don't have an account yet?