LEM RS232 SBUS Converter for LEM Battery Monitoring System
Features
Proprietary LEM SBUS String Interface
For OEM Sentinel Communication
Datasheet
Product Datasheet
Sentinel 3+ Battery Sensor Gen 3+, DIN Rail Mount
Compact and versatile 3 in 1 Battery sensor for monitoring of critical battery systems, included Flooded Cell, and VLRA types.
The Sentinel 3+ is a state of the art, System on Chip (SoC) digital transducer designed to monitor VRLA, gel or flooded stationary battery systems. Data is transmitted over a dedicated communication bus to proprietary and non-proprietary devices
Features
Din Rail Mount, Compact Design
LED status indicator
Temperature patch for direct battery measurement
Communication interface isolation 2.16 kV
Fast, simple fittings
, Voltage, Temperature and True AC Impedance Measurement
S-Bus Output (Interface with OEM equipment)
Suitable for Transformerless UPS systems (may require Common mode Isolator)
Isolated plastic case recognised according to UL94-V0
Advantages
Excellent sensitivity, accuracy, and repeatability
High current stimulation for secure impedance measurement
Improved immunity to Common Mode transients in newer UPS topologies (ie. transformerless, using fast IGBTs and/or a floating battery with respect to earth ground).
Applications
UPS
Telecommunications
Battery supplied applications
Application Domains
Energy & Automation
Industrial.
Utilities
Fire & Safety system
Remote monitoring
LEM Part Number
BM Sentinel 3+
Technology
SoC 3 in 1 sensor
CE Approved
Yes
Supply Voltage
0.9 .. 16VDC @ 30mA
Voltage Measurement Range
0.9 .. 16VDC @ 30mA
Temperature Measurement Range
-10°C / 70°C
Output
S-Bus Digital protocol
Isolation
2.16kV (AC, 50Hz, 1 min)
S-Bus Baud Rate
9600 bps
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 70°C
Accuracy
0.5%
Termination Style
6 Pin Connector (for BM CBL POW 0.4/0.6M)
Unit Weight
70g
Factory Pack Qty
6
Â
Datasheet
Used to monitor and measure battery Impedance, Voltage, and Surface Temperature.
Product Datasheet
S-Bus Protocol Information
OEM Software Tools
Sentinel 3 Commander Test Program
Sentinel Troubleshooting
Harsh EMC
Application Notes
In a UPS, the current drawn by the inverter contains line frequency harmonic components (mostly 2nd, 4th and 6th). Part of this ripple current flows through the battery, to which is connected the Sentinel.
As the Sentinel itself uses an excitation current for the impedance measurement, so the presence of ripple current can interfere with the measurement and thus cause errors. The table below quantifies the additional error resulting from 1A rms of ripple current, for different combinations of ripple current harmonics and bloc voltage.
Table 1: Additional errors for impedance measurement due to ripple current (See datasheet)
Notes:
The error values are the maximum, and are normalized for 1A rms of ripple current. The error is proportional to the ripple current; for example, if the ripple current was 2A rms the error will increase by factor 2.
SSPA-YELLOW-4mm (2pcs), YELLOW 4mm Fully Sheathed Piggy Back Safety/Banana Plugs, 32 Amp, 1000V Rated. For Test Equipment/Leads
32 Amp / 1000V AC (rms) or DC Maximum Rating
Fully Sheathed
4mm Piggy Back Plug Type
Suitable For Laboratory Test Equipment
Crouzet Syr-Line Single Pole Multifunction Timer With SP-NO/NC Contacts
MDF Timers Syrline 48x48mm - 1 Relay 10A :
Large LED or LCD Screen (13.2 mm)
Multi-function and single-function
Basic & Advance configuration modes
Multi-range (0.05 s – 9999 h)
Multi-voltage (24-240 V AC/DC)
1 or 2 relay outputs (Changeover)
Memory option in event of a break in supply
Lock function › Up or down timing
DIN Sized (48x48 mm) Housing
Compact body (63 mm long)
Water & Dust-proof (IP66)
8-Pin
Multifunction Timers Include The Following :
Function A Delay on energisation 1 relay
Function Ac Timing after closing and opening of control contact 1 relay
Function Ad Timing delay on start with memory 1 relay
Function B Timing on impulse one shot 1 relay
Function C Timing after impulse 1 relay
Function H Timing on energisation 1 relay
Function L Recycler (OFF start) with memory 1 relay
Function Li Recycler (ON start) with memory 1 relay
Function D Symmetrical Flashing (OFF start) with Memory 1 relay
Function Di Symmetrical Flashing (ON start) with Memory 1 relay
Specification
Crouzet Part Number
MDF1R10MV2 (Syr-Line Timer Single Pole 5A Multifunction, 12 - 240VAC/DC, 48x48 mm)
Function
Multifunction Timer A - Ac - Ad - B - C - H - L - Li - D -N - Di
Nominal Voltage
12 → 240 V AC/DC
Digital Output
1 x C/O (SPDT) (Changeover -Single Pole Double Throw), 250VAC/DC @ 10 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 0.05→9999h
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Isolation
1kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
8 Pin Base
Weight
180g
Certification
CE, cULus,CCC, ROHS, Reach, WEEE
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Trent FRS4-C40 320V 1P (1+0) (R), Class II/Type 2, AC Surge Protection Device (SPD), 1 Pole In = 20/50kA L-N, L/N-PE, Un = 230VAC, Uc = 320VAC, DIN Rail Mount, High Energy MOV Type, with Remote Contacts
Specifications
Â
Trent part number
FRS4-C40 230V 1P (1+0) (R)
Nominal Voltage (Un)
230VAC
Maximum Operating Voltage (Uc(
320VAC
Voltage Protection Level (Up)
<1.5kV
No of Poles
1
Category IEC / EN / VDE
Class II / Type 2
Location of use
Sub Distribution Boards
Protection modes
L/N-PE, High Energy MOV
Additional Remote Contacts
YES
Protective element
MOV
Surge discharge rating
Imax up to 40kA(8/20us) L/N-PE 320VAC
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Â
Datasheet
Product Datasheet
FRSS-RJ45/8D, Surge Protection Device For RJ45 1Gb/s Ethernet & POE Devices 3 Pole , Un = 5VDC(Line)/48VDC(POE), Uc = 45VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation, Nominal Discharge 5kA, Maximum Discharge 10kA, Slim 18mm Wide Module
Â
Application
IT Systems
Coarse and Fine Protection
Industrial Control System
Measurement System
RJ45 Ethernet Systems
POE Compliant
1000Mb/s Compliant
Â
Specifications
Trent part number
FRSS-RJ45/8D
Nominal Voltage (Un)
5VDC (Line) / 48VDC (POE)
Maximum Permissable Voltage (Uc)
45VDC
No of Poles
3
Location of use
IT Communications Line/signals 1000Mb/s POE supported
Protection modes
TX+/TX-/RX+/RX-/PE
Additional Remote Contacts
No
Protective element
MOV
No Fault/Fault Indication
N/A
Surge discharge rating
Per pole 5kA (8/20uS) Nominal, 10kA (8/20uS) Max  Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
150g
Standards
IEC61643-21; GB 18802.21 ; YD/T 1542
Â
Datasheet
Product Datasheet
GDT/MOV/TVSÂ Tester
SPD Tester
Schurter 0034.9856 Fuse Kit, 15pcs x 18 types FSF Series
Features
Meets UL and IEC standards
UL Recognized for 250VAC
High breaking capacity of 1.5 kA @ 250VAC
Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation
Applications
Electrical Appliances
POwer Supply Adaptors
Switch Mode Power Supplies
Avionics
In-line protection
Specification
Schurter Part Number
0034.9856 Fuse Kit
Fuse Type
Various FSF Series
Nominal Voltage
250VAC
Nominal Current (AC rms)
2 Amp
Tested Breaking Capacity
1.5kA @250VAC
Dimensions
5 x 20mm
Fuse Holder
Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 85°C
Unit Weight
350g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
0031-2203 Shock Proof Fuse Holders
Schurter, 3-146-121 (T12-121SR-8), 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts & Indicator Tag
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Threaded neck type
Thermal circuit breaker
1-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Auxiliary Contacts
Indicator Ribbon/Tag
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
3-146-121 (T12-121SR-8)
Functions
1 Pole Thermal Circuit Breaker
Button Action
Manual ON/OFF
Nominal Voltage
240VAC @ 50Hz or 28VDC
Nominal Current Range
8 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Insulation Resistance
500VDC
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
10g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Â
6051.2067, C13/C14 Cordset Interconnecting, V-Lock cord retaining, 1.5 m, V-75, black 10A 10mm
Features
1.5M Length
Appliance Inlet C13/C14 acc to IEC 60320-1
70 °C pin Temperature
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 120 °C, 10A, Protection Class I
Other Pin versions available on request
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Â
Specification
Schurter Part Number
6051.2067
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
Operating Temperature
-25°C to 70°C
Filter Type
N/A
Fuse Holder
N/A
Line Switch
N/A
Mounting
Wire Screw Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
C13 / C14
Weight
150g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV
VDE/UL/CSA/CE/ROHS
Yes
Â
Datasheet
Product Datasheet
Fastron Electronics GTD-V4-A-44, Signal Conditioner/Voltage Transducer, 0-10VDC input, 100-240VAC/DC aux, Dual 0-10VDC outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-V4-A-44
Conditioned Output
2 x 0-10V
Input
0-10V
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Fastron Electronics GTD-DV6-D-11, DC Voltage Transducer, 0-300VDC input, 22-60VAC/DC aux, Dual 4-20mA outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DV6-D-11
Conditioned Output
2 x 4-20mA (Average RMS)
Input
0 - 300VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent I^2t (aR) Blade Style Semiconductor Fuse, 500 Amp, 690VAC, Square Body, Size_Body Size 1*/80, DIN 43 653, 200kA (78mm Hole Centers) F170M3014
Features
Square Body, Size_Body Size 1*/80, DIN 43 653
Wide Range of I^2t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I^2t
Short Circuit Protection
DC or AC Motor I^2t Protection
Battery Fuse
Specification
Trent Part Number
F170M3021
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I^2t Rating (660V)
180000A^2/s
Nominal Current (RMS DC)
500 Amp
Tested Breaking Capacity
200kA (78mm Hole Centers) @ 690VAC
Dimensions
45 x 104 x 45mm
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
30W
Termination Style
M10
Unit Weight
350g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet