F135 Series Panel Mount 3 Phase Solid State Contactors, 13 to 240 Amp per P hase 70-480VAC Switching, 90-280VAC or 4-32VDC Control, Contactor Style Modules
Ratings from 13A to 240 Amp per phase @ 30-480 VAC
Thermal Overload Detection (via Bimetal Thermal Switch)
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Optional Fuses(Loose), Varistors(mounted) or 240VAC Snubber(mounted)
Specification
Part Number
F135 Series
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC or 90-280VAC
Load Current
13 -150Amp (rms) per Phase @ 50 Deg C
Surge Capability (10ms)
597-2000 Amp (peak)
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
70-480VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Factory Pack Qty
1
Dimensions and Fuse Kits
Part Number
Approximate Dimensions
Weight
Panel Mount Fuse Kits
DIN Rail Mount Fuse Kits
F135-4-13A(D)
L:115 x W:125 x D:95mm (Figure 1)
0.75kg
20-30 Amp 660VAC Fuse Kit
Trent 25 Amp Cartridge Fuse
F135-4-25A(D)
L:155 x W:125 x D:185mm (Figure 5)
3.2kg
20-50 Amp 660VAC Fuse Kit
Trent 40 Amp Cartridge Fuse
F135-4-50A(D)
L:255 x W:125 x D:185mm (Figure 6)
4.5kg
20-50 Amp 660VAC Fuse Kit
Trent 63 Amp Cartridge Fuse
F135-4-75A(D)
L:255 x W:125 x D:185mm (Figure 6)
4.5kg
80-120 Amp 660VAC Fuse Kit
Trent 80 Amp Cartridge Fuse
F135-4-90A(D)
L:255 x W:125 x D:185mm (Figure 6)
4.5kg
80-120 Amp 660VAC Fuse Kit
Trent 125 Amp Cartridge Fuse
F135-4-120A(D)
L:255 x W:125 x D:195mm (Figure 6)
4.5kg
80-120 Amp 660VAC Fuse Kit
N/A
F135-4-180A(D)
L:335 x W:125 x D:195mm (Figure 7)
5.5kg
120-180 Amp 660VAC Fuse Kit
N/A
F135-4-240A(D)
L:335 x W:125 x D:195mm (Figure 8)
6.8kg
210-240 Amp 660VAC Fuse Kit
N/A
Â
If you need a fan Control Relay you can find it here in our store.
Datasheet
F115_135 Series Datasheet
Furison FC150A3, PID Temperature Controller for HVAC, 87.6x34.5mm (71x29m Cutout), 100-240VAC, 2 x Programmable Relay Outputs, Includes NTC Sensor
3-digit display suit refrigeration temperatures to 1 Degree
Drip-proof / Dust-proof IP64 (front panel only)
Each unit needs just 71 x 29mm panel space
3 minute delay protection
Automatic 15 minutes ON, 30 minutes OFF on sensor failure
Overtemperature Alarm including 10 Amp Relay, Buzzer and LED Blinking
Ultra High temperature 99 - 120 Deg C Displays "HH"
Specification
Furison Part Number
FC150A3
Control Output
2 x SPDT Relay 10A(Resistive)for Heat/Cool/Compressor/Alarm
Input
NTC Probe (Included with 2 Meter wire length)
Cooling/Cooling Outputs
2 x 230VAC 10 Amp Relay Contact
Mounting Style
71 x 29mm Panel Mount
Supply Voltage
100-240VAC
Termination Style
Screw
Weight
150g
Factory Pack Qty
1
Certifications
UL, CE
Â
Datasheet
Download Datasheet
Meanwell LPV-20-24, 24VDC 0.84A 21W Universal Power Supply with Flying Leads, In Wall, In Ceiling Mount, Used as LED Driver
Supply Voltage: 120-370VDC or 85-264VAC
Output Voltage: 24V
Output Current: 840mA
Power Rating: 20.2W
Connection: flying leads
Short Circuit, Overload, Overvoltage Protected
IP67 for internal wall mounting
Also Available
LPV-20-5 (5VDC)
LPV-20-12 (12VDC)
LPV-20-15 (15VDC)
Datasheet
Product Datasheet
Alternatives
Schurter lpv-20-24
Fastron Electronics SCT-F16-120-40mA(SCT-F16-120-040A), 40mA, 120Amp measurement Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
40 mAmp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F16-120-040A
Technology
Split Core AC Current Transformer
Ratio
120/40mA
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
40 mAmp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
120Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FRI 8-01/5, Current Monitoring Relay AC 0.5 - 5 Amp, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/5
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.5 - 5 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Varsi-Raycap V275E40, Varistor, 275VAC, 350VDC, E40 Package 565W Metal Oxide Varistor (MOV), Equivalent to Epcos SIOV-B40K275 Features
Features
High Energy Absorption Rating
Industry Standard Package
Wide Operating Range 35 - 1100VAC
High Peak Current Capability (70kA)
UL/CSA/ROHS/ISO9001:2015 Approved
Panel Mount
Screw Terminals
APPLICATION AREAS:
1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems).
2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes.
3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules.
Specification
Varsi-Raycap Part Number
V275E40
Operating Voltage AC (50-60Hz)
275V
Operating Voltage DC
350V
Average Power Dissipation
1.4W
Permissable Peak Current
40kA
Energy Absorption(2ms)
565W(max)
Tolerance(Vn)
+/- 10%
Termination Style
Screw
Weight
59g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CSA
Yes
Â
Datasheet
Product Datasheet
Application Notes
Technical Blog MOV Article
GDT/MOV/TVSÂ Tester
SPD Tester
Fastron Electronics SCT-F36-200-5A, 5 Amp, 200Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F36-200-5A
Technology
Split Core AC Current Transformer
Ratio
200/5 Amp
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Crydom HSP-2 Thermal Pad for Standard Single Phase SSR
Features
No need for thermal grease
Self Adhesive
Clean alternative to Thermal Paste
ROHS
Datasheet
Product Datasheet
Alternative Products
Thermal Paste Pack
Gigavac GX14CAB, Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GX14CAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Gigavac GV200QA-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 48VDC External Economiser Coil, 38cm Flying leads, WITHOUT Auxiliary Contact, IP67
Features
External Economiser Coil (Requires External Economser)
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV200QA-1
Main Contact Type
SPST-NO
Auxiliary Contact Type
None
Coil Voltage
48VDC Economiser
Load Current
500+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
External Economiser Coil (No Internal Economiser)
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-50-420-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-420-24
Analogue Output
4-20mA
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Â