HS259DR + PMP4850WP, DIN Mount, Proportional Controller, 380-480VAC 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 90-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
HS259DR + PMP4850WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
25 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR + Overvvoltage Protection
Mounting Style
Panel Mount
Load Voltage Range
345-530VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
0.4kg
Factory Pack Qty
20
Â
Datasheet
PMP24 Series Datasheet
PMP24 Installation/Wiring Guide
GFIN
Equivalent Parts
Contact Us for Possible Replacement
Â
Schurter 4435.0173 TA35-CFTBF050C0, 1 Pole Rocker Switch, Non Latched, 5 AMP, 240VAC, 60VDC, Thermal Overload Protection, Faston Connection, Black with White I/O Embossed
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Rocker Switch
1-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4435.0173 TA35-CFTBF050C0
Functions
1 Pole Rocker Switch, with 1 Bimetal Thermal Overload Circuit Breaker
Nominal Voltage
240VAC @ 50Hz or 60VDC
Nominal Current Range
5 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Insulation Resistance
500VDC
Illumination
None
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
10g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Â
Schurter 4435.0478 TA35-CFTBL160C0, 1 Pole Rocker Switch, Non Latched, 16 AMP, 240VAC, 60VDC with Thermal Overload Protection, Faston Connection, Black with White I/O
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Rocker Switch
Thermal circuit breaker
1-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4435.0254 TA35-CFTBL160C0
Functions
1 Pole Rocker Switch with Bimetal Thermal Circuit Breaker
Nominal Voltage
240VAC @ 50Hz or 60VDC
Nominal Current Range
16 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Insulation Resistance
500VDC
Illumination
None
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
10g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Â
LEM HAZ 12000-SB Series Open Loop Hall Effect Current Transducer
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
Features
Instantaneous output version +/-10V, +/-20mA
True RMS output versions 4-20mA, 0-10V putput
Hall effect measuring principle
Galvanic isolation between primary and secondary circuit
Instantaneous voltage output
Isolation voltage 17kV Rms /50 Hz /1min
Low power consumption
Package in PBT meeting UL 94-V0
Instantaneous voltage output
Advantages
Easy installation
Small size and space savings
Only one design for wide Ratings range
High immunity against external interference
Applications
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Power supplies for welding and telecom applications
Application domain
Industrial
Traction
Specification
LEM Part Number
HAZ 12000-SB
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
+/- 15VDC
Load Current (RMS + DC)
12000 Amp
Overload Rating
30000 At
Output
+/-10 V Instantaneous
Isolation
17kV (AC, 50Hz, 1 min)
Bandwidth
DC-3kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
F2023A (FUJICON)
Unit Weight
6kg
Factory Pack Qty
2
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Trent NBR-20 001 13-100A-500V-120kA-NH00, Semiconductor Type gG/gL Fuse, 100 Amp, 120kA, 500VAC, NH00, 78 x 46 x 29.5mm
Features
Square Body Size NH00
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500Â V Voltage Rating
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-20 001 13-100A-500V-120kA-NH00
Fuse Type
I²t gG/gL Class
Nominal Voltage
500VAC @ 50Hz
Nominal Current (RMS + DC)
100 Amp
Tested Breaking Capacity
120kA @ 690VAC
Dimensions
78 x 46 x 29.5mm
Hole Centers
N/A Blade Style
Mounting
Fuse Holder Mounting
Operating Temperature Range
-40°C / 125°C
Termination
Blade
Unit Weight
900g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Trent NBR-20 001 13-80A-500V-120kA-NH00, Semiconductor Type gG/gL Fuse, 80 Amp, 120kA, 500VAC, NH00, 78 x 46 x 29.5mm
Features
Square Body Size NH00
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500Â V Voltage Rating
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-20 001 13-80A-500V-120kA-NH00
Fuse Type
I²t gG/gL Class
Nominal Voltage
500VAC @ 50Hz
Nominal Current (RMS + DC)
80 Amp
Tested Breaking Capacity
120kA @ 690VAC
Dimensions
78 x 46 x 29.5mm
Hole Centers
N/A Blade Style
Mounting
Fuse Holder Mounting
Operating Temperature Range
-40°C / 125°C
Termination
Blade
Unit Weight
900g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Trent NBR-20 001 13-63A-500V-120kA-NH00, Semiconductor Type gG/gL Fuse, 63 Amp, 120kA, 500VAC, NH00, 78 x 46 x 29.5mm
Features
Square Body Size NH00
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500Â V Voltage Rating
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-20 001 13-63A-500V-120kA-NH00
Fuse Type
I²t gG/gL Class
Nominal Voltage
500VAC @ 50Hz
Nominal Current (RMS + DC)
63 Amp
Tested Breaking Capacity
120kA @ 690VAC
Dimensions
78 x 46 x 29.5mm
Hole Centers
N/A Blade Style
Mounting
Fuse Holder Mounting
Operating Temperature Range
-40°C / 125°C
Termination
Blade
Unit Weight
900g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Trent NBR-20 001 13-50A-500V-120kA-NH00, Semiconductor Type gG/gL Fuse, 50 Amp, 120kA, 500VAC, NH00, 78 x 46 x 29.5mm
Features
Square Body Size NH00
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500Â V Voltage Rating
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-20 001 13-50A-500V-120kA-NH00
Fuse Type
I²t gG/gL Class
Nominal Voltage
500VAC @ 50Hz
Nominal Current (RMS + DC)
50 Amp
Tested Breaking Capacity
120kA @ 690VAC
Dimensions
78 x 46 x 29.5mm
Hole Centers
N/A Blade Style
Mounting
Fuse Holder Mounting
Operating Temperature Range
-40°C / 125°C
Termination
Blade
Unit Weight
900g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Trent NBR-20 001 13-40A-500V-120kA-NH00, Semiconductor Type gG/gL Fuse, 40 Amp, 120kA, 500VAC, NH00, 78 x 46 x 29.5mm
Features
Square Body Size NH00
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500Â V Voltage Rating
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-20 001 13-40A-500V-120kA-NH00
Fuse Type
I²t gG/gL Class
Nominal Voltage
500VAC @ 50Hz
Nominal Current (RMS + DC)
40 Amp
Tested Breaking Capacity
120kA @ 690VAC
Dimensions
78 x 46 x 29.5mm
Hole Centers
N/A Blade Style
Mounting
Fuse Holder Mounting
Operating Temperature Range
-40°C / 125°C
Termination
Blade
Unit Weight
900g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet