Vishay ACMKP525.3.25.00, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 25KVAR @ 525V, 16.7KVAR @ 415VAC, 3 x 96.2uF, Direct Replacement for PhMKPg525.3.25,00-84
Characteristics and utility
25kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
UL 94 V0 Resin
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Vishay Part Number
ACMKP525.3.25.00 (Replaces PhMKPg525.3.25,00-84)
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
85 x 265mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar @ 525V
25 Kvar (16.7Kvar @ 415V)
Size
85 x 265mm
Capacitance
3 x 96.2uF (16.7KVAR @ 415V)
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
27.5 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
1.7kg
Factory Pack Quantity
25
Â
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Electronicon 275.536-504600/221K02 10kvar 480V 50Hz, Power Factor Correction Capacitor, 3 Phase, 85 x 245(+32)mm Gas Filled, 3 x 46uF, Possible Replacement to Frako LKT 110.4-480-DPS, SINGLE SIDED TERMINALS
Characteristics and utility
10kVar @ 480V @ 50 HzÂ
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.536-504600_221K02 10kvar 480V 50Hz
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
75Â x 245(+25)mm ( Type K terminals)
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
480V @ 50Hz
Kvar
10 Kvar
Capacitance
3 x 46uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 18 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal (Type K Terminals)
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
1.3kg
Factory Pack Quantity
25
Â
Datasheet
Product Datasheet
PFC Capacitor Comparison Chart
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Rishabh Rish Con M+ CM44111411, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, USB Programming Port, Modbus RTU Comms, without display
Measures Active Power/Phase Angle/Power Factor
Measures Apparent/Reactive/Active Power
Analogue output setting 0-20mA/4-20mA/0-10V (Programmable)
Free Program Software
300mS response time
PC 94 UL V0
Input Voltages, Current or Power Measurements can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con CM44111411
Functions
Active Power/Phase Angle/Power Factor Transducer 4 wire
Measurement Output
4 x 4-20mA/0-20mA/0-10V User Selectable and Programable
Relay Output
N/A
Relay Type
Voltage Free Contact, 0.5 Amp @ 250VAC
Input
100Â - 600VAC L-L 50/60Hz
Overload (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-10 - 55°C
Supply Voltage
85-285VAC/DC
Accuracy
0.2% Current, Voltage (0.5% Power)
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Mounting Size
122.5 x 66 x 106.5mm
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Product User Manual
Technical Support
Rish Con P setup procedure blog
Brand Comparison to Iskra UMT540 or MT540 Series
Â
Rishabh Rish Con M+ CM44111111, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, 2 x Relay Outputs, USB Programming Port, Modbus RTU Comms, without display
Measures Active Power/Phase Angle/Power Factor
Measures Apparent/Reactive/Active Power
Analogue output setting 0-20mA/4-20mA/0-10V (Programmable)
Free Program Software
300mS response time
PC 94 UL V0
Input Voltages, Current or Power Measurements can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con M+ CM44111111
Functions
Active Power/Phase Angle/Power Factor Transducer 4 wire
Measurement Output
4 x 4-20mA/0-20mA/0-10V User Selectable and Programable
Relay Output
2
Relay Type
Voltage Free Contact, 0.5 Amp @ 250VAC
Input
100Â - 600VAC L-L 50/60Hz
Overload (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-10 - 55°C
Supply Voltage
85-285VAC/DC
Accuracy
0.2% Current, Voltage (0.5% Power)
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Mounting Size
122.5 x 66 x 106.5mm
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Product User Manual
Technical Support
Rish Con P setup procedure blog
Brand Comparison to Iskra UMT540 or MT540 Series
Â
Rishabh Rish Con M+ CM44111211, , Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V Outputs, 2 x Relay Outputs, USB Programming Port, Modbus RTU Comms, without display
Measures Active Power/Phase Angle/Power Factor
Measures Apparent/Reactive/Active Power
Analogue output setting 0-20mA/4-20mA/0-10V (Programmable)
Free Program Software
300mS response time
PC 94 UL V0
Input Voltages, Current or Power Measurements can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con M+ CM44111211
Functions
Active Power/Phase Angle/Power Factor Transducer 4 wire
Measurement Output
2Â x 4-20mA/0-20mA/0-10V User Selectable and Programable
Relay Output
2
Relay Type
Voltage Free Contact, 0.5 Amp @ 250VAC
Input
100Â - 600VAC L-L 50/60Hz
Overload (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-10 - 55°C
Supply Voltage
85-285VAC/DC
Accuracy
0.2% Current, Voltage (0.5% Power)
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Mounting Size
122.5 x 66 x 106.5mm
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Product User Manual
Technical Support
Rish Con P setup procedure blog
Brand Comparison to Iskra UMT540 or MT540 Series
Â
Electronicon 275.168-609600 / 221K02 25kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 245(+33 +/-2)mm Gas Filled, Requires Discharge Resistor, 3 x 96uF, Can Replace Epcos MKP525-D-25.0 [Double Sided Terminals]
Characteristics and utility
25kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.168-609600 / 221K02 25kvar 525V 50Hz
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
95Â x 245(+33 +/-2)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
25 Kvar
Capacitance
3 x 96.2uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 45 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
2.3kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Can Replace Epcos MKP525-D-25.0
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Electronicon 275.256-606800 17.6 kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 85 x 245(+32)mm Gas Filled, 3 x 68uF, Requires Discharge Resistor
Characteristics and utility
17.6kVar @ 525V @ 50 HzÂ
Three phase capacitor internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.256-606800 17.6 kvar 525V 50Hz
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
85 x 230(+32)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
18.6Â Kvar
Capacitance
3 x 68uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 27 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
2.3kg
Factory Pack Quantity
25
Â
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
D44010050000000, Power Factor Correction Capacitor, 3 Phase, DWCAP 10KVAR 440V 50HZ, Dry Type, 70x230mm, 3 x 54.81uF
Characteristics and utility
10.0 kVar @ 440V @ 50 Hz 12.5.0kvar 12.5kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
True triple safety
Overpressure disconnection system
Protection by internal fuses
DWCAP system (patented) internal windings Displacement
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR EnergÃa
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
D44010050000000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
70 x 230mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
440V @ 50Hz
Kvar
10.0 Kvar
Capacitance
3 x 54.81uF
Tolerance On Capacitance
-5% + 10%
Current (In)
12.03 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
1.5kg
Factory Pack Quantity
25
Â
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Voltage Derating Tables
Â
D44005050000000, Power Factor Correction Capacitor, 3 Phase, DWCAP 5KVAR 440V 50HZ, Dry Type, 70x230mm, 3 x 27.4uF
Characteristics and utility
5 kVar @ 440V @ 50 Hz 12.5.0kvar 12.5kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
True triple safety
Overpressure disconnection system
Protection by internal fuses
DWCAP system (patented) internal windings Displacement
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR EnergÃa
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
D44005050000000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
70 x 230mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
440V @ 50Hz
Kvar
5.0 Kvar
Capacitance
3 x 27.4uF
Tolerance On Capacitance
-5% + 10%
Current (In)
12.03 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
1.5kg
Factory Pack Quantity
25
Â
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Voltage Derating Tables
Â
Iskra Doo UMT540-HSHFNAAAM, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 3 Programmable analogue outputs, 1 Relay Alarm Output, USB, Ethernet, RS485 Comms
(U)MT version = Ring type terminal block
Class 0.5S Active, Class 0.2 Reactive (EN 60688) , Class 0.1 on Comms
RS485 Comms as standard
Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics
Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N
Adjustable tariff clock, display of electric energy consumption in optional currency
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Measurements of energy in all 4 quadrants Average values of measurands per interval
Certified ship version available
The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).
Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms
32 Adjustable Alarms
Input frequency 50/60 Hz or 400 Hz
RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard
MODBUS RTU communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal Supply 24-300VDC or 40-276VAC
Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V
User-friendly PC MiQen software
Optional Remote Display Support
Specification
Iskra Doo Part Number
UMT540-HSHFNAAAM
Functions
3 Phase Power Transducer
Supply Voltage
24-300VDC or 40-276VAC
Nominal Measurement Range
600V L-N, 5 Amp
Maximum Measurement Range
600V L-N, 12.5 Amp
Alarm
N/A
Tariff Input
N/A
Output(s)
3 x Analogue, 1 x Relay Alarm
Accuracy
Class 0.2 (I,U,F,PF,θ,THD) Class 0.5s(Active), Class 0.2 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Terminations
Ring Type Terminal Block
Isolation
3.5kV
Comms
USB (standard) RS232 2400-115200 b/s (RS485 Optional)
Weight
900g
Enclosure Material
UL94,
Factory Pack Qty
1
EU Directives
EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Â
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Â
Datasheet
Product Datasheet
Software
MiQen Setting Software
Electronicon 275.166-607700 / 221K02 20Kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 77uF, FEED THROUGH TERMINALS, Requires Discharge Resistors
Characteristics and utility
20kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.166-607700 / 221K02 20Kvar 525V 50Hz
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
95 x 230(+32)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
20Â Kvar
Capacitance
3 x 77uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 22 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
1.5kg
Factory Pack Quantity
30
Â
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
PFC 08-8-R-RTC, Power Factor Regulator & Kwh Power Quality Meter 96x96mm with RTC, 8 Step, 30-550V 50/60HZ, 240VAC Aux
Single 1/5A CT Sensing
Automatic Step Sensing (After start up sequence)
Isolated Switching of Power Factor Correction Contactors
Cos Ï• Setting 0.85 to 0.95 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 12 steps
Measurement System - Automatic/Manual
240VAC Aux Supply
Modbus RS485
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
Â
Specification
Rishabh Part Number
PFC 08-8-R-RTC
Function
Reactive Power Correction
Nominal Voltage (Un)
110-480VAC Line to Line
Supply Voltage
240VAC (L-N), 15VA 40-70Hz +/-10%
Relay Rating
250VAC/10Amp
Panel Size
96 x 96mm
Switch Delay Time
10s - 1800s User Adjustable
Alarm
1 x Relay as above
Temperature Alarm
1 x Relay as above
Re-connection Delay Time
10 - 1800s User Adjustable
Desired Power Factor
0.80 IND - 0.80 CAP
Number of Output Relays
9
Smallest Capacitor Current
10mA
CT Input Range
1/5Â Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Panel Size
96x96mm Panel Mount
Comms
RS485
Termination Style
Screw
Weight
700g
Certification
IEC 61326-1:2012, Table 2 (EMC), IEC 62053-21 (Accuracy), IEC 61010-1-2010 (Safety), IEC60529 (IP Rating Dust & Water)
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to IEC 61010-1-2010, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
Product Datasheet
User Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog