Power Controllers
-
H5/100R + PMP2425W, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Panel Mount
H5/100R + PMP2425W DIN Mount, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 90-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number H5/100R + PMP2425W Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 25 Amp (rms) Surge Capability 296 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 90-280VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 800g Factory Pack Qty 20 Datasheet PMP24 Series Datasheet PMP24 Installation/Wiring Guide H5 Datasheet Equivalent Parts Contact Us for Possible Replacement
$162.00
$191.16 inclGST -
GFIN/70M-DR + PMP2425W DIN Mount, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount
GFIN/70M-DR + PMP2425W DIN Mount, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 90-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number GFIN/70M-DR + PMP2425W Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 25 Amp (rms) Surge Capability 296 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 90-280VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 800g Factory Pack Qty 20 Datasheet PMP24 Series Datasheet PMP24 Installation/Wiring Guide GFIN Product Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Parts Contact Us for Possible Replacement
$272.00
$320.96 inclGST -
MCBC4850CF, Solid Sate Relay based Burst Fire Controller, 480VAC, 50 Amp, 0-10V Input, 20 Cycles
Crydom MCBC4850CF, Solid Sate Relay based Burst Fire Controller, 480VAC, 50 Amp, 0-10V Input, 20 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC4850CF Switching Type Burst Fire (10 Cycles) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 50 Amp (rms) Surge Capability 625 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 330-530VAC Overvoltage Vpk 1200V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
$223.00
$263.14 inclGST -
Phase Angle Controller, F330 Series 3 Phase, Cards Only
Oztherm F330 Series 3 Phase SCR Phase Angle Controller Spare Card Set, Can Replace Novatherm C3000 & C3000A Features 100% Australian Made 3 Phase, Phase Angle Controller or DC Soft Starter 4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control Fully enclosed IP20 Phase angle switching Aluminium Frame Removable perspex Cover Applications Electrical Ovens, Kilns, or Furnaces AC Soft Starter Controlled Power Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Sheet Metal Welding Available Options Voltage Regulation AC (A) Current Limit and Trip AC (C) Current Limit and Trip DC (CE) Current Control/Constant Current AC(CC) Current Control/Constant Current DC(CCE) Power Limit (PW) Phase Loss Alarm/Dispable (PH) Loose Semiconductor Fuses (F) Internal Semiconductor Fuses (FI) Thermal Overlad Protection (T) Special Features Contact Us for Possible Replacement for customised features Specification Oztherm Part Number F330 Series 3 Phase, Phase Angle Controller Rated Operationg Temperature 50°C SCR Configuration 3 Phase AC Swtich Control Voltage 4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration) Load Current N/A Control Range 0-100% Special Feature (Optional) Current Limit & Trip AC or DC, Current Control AC or DC, Voltage Regulation AC, Power Limit, Phase Loss Alarm, Thermal Overload Protection, Fuses Mounting Style Panel Mount Supply Voltage Range 380-440VAC +/-10% Soft Start 1-20mS Termination Style Screw Unit Weight up to 10kg Factory Pack Qty 1 Brochure F330 Brochure Technical Docs Installation and Commissioning Manual Standard Thyristor Wiring Diagram Control Card Wiring Diagram F311A1 New CCE option PCB1019-XX Wiring Diagram Bridge Output Thyristor Wiring Diagram Primary Transformer Wiring Diagram Start Delta Wiring Diagram Calibration Procedure Blog PDF Copy of Calibration Procedure Customised models Customised models list Contact Us for Possible Replacement for customised features not listed
$1,168.00 - $14,170.00
-
2 Leg Burst Fire Controller, F430 Series, 380-440VAC, Cards Only
Oztherm F430 Series 2 Leg SCR Burst Controller Spare Card Set 100% Australian Made 3 Phase Burst Controller 4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control Fully enclosed IP20 Burst Fired switching Aluminium Frame Removable perspex Cover Applications Electrical Ovens, Kilns, or Furnaces Secondary or Direct Control only Controlled Power Applications Electric Boilers Smelting of Raw Metals Suitable for extreme environments such as mining Room/Chamber heating Available Options Current Limit and Trip AC (C) Phase Loss Output (PH) Partial Load Failure (PLF) Loose Semiconductor Fuses (F) Internal Semiconductor Fuses (FI) Thermal Overlad Protection (T) Special Features Contact Us for Possible Replacement for customised features Specification Oztherm Part Number F430 Series 2 Leg Burst Controller (Cards Only) Rated Operationg Temperature 50°C SCR Configuration 3 Phase AC Swtich Control Voltage 4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration) Load Current 30 - 120Amps Per Phase Control Range 0-100% Special Feature (Optional) Current Limit & Trip AC, Phase Loss Alarm, Partial Load Failure Alarm, Thermal Overload Protection, Fuses Mounting Style Panel Mount Supply Voltage Range 380-440VAC +/-10% Soft Start 1-20mS Termination Style Screw Unit Weight up to 3kg Factory Pack Qty 1 Datasheet F430 Brochure F430 Installation and Commissioning Manual
$1,063.00 - $1,459.00
-
Burst Fire Controller, F431 Series 3 Phase, 380-440VAC, Cards Only
Oztherm F431 Series 3 Phase SCR Burst Controller Spare Card Set 100% Australian Made 3 Phase Burst Controller 4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control Fully enclosed IP20 Burst Fired switching Aluminium Frame Removable perspex Cover Applications Electrical Ovens, Kilns, or Furnaces Secondary or Direct Control only Controlled Power Applications Electric Boilers Smelting of Raw Metals Suitable for extreme environments such as mining Room/Chamber heating Available Options Current Limit and Trip AC (C) Power Limit (PW) Phase Loss Output (PH) Partial Load Failure (PLF) Loose Semiconductor Fuses (F) Internal Semiconductor Fuses (FI) Thermal Overlad Protection (T) Special Features Contact Us for Possible Replacement for customised features Specification Oztherm Part Number F431 Series 3 Phase Burst Controller (Cards Only) Rated Operationg Temperature 50°C SCR Configuration 3 Phase AC Swtich Control Voltage 4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration) Load Current 30 - 120Amps Per Phase Control Range 0-100% Special Feature (Optional) Current Limit & Trip AC, Power Limit, Phase Loss Alarm, Partial Load Failure Alarm, Thermal Overload Protection, Fuses Mounting Style Panel Mount Supply Voltage Range 380-440VAC +/-10% Soft Start 1-20mS Termination Style Screw Unit Weight up to 3kg Factory Pack Qty 1 Datasheet F431 Brochure F431 Installation and Commissioning Manual
$1,113.00 - $1,724.00
-
MCBC2450CL, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 0-10V Input, 20 Cycles
Crydom MCBC2450CL, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 0-10V Input, 20 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC2450CL Switching Type Burst Fire (20 Cycles) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Requires DC Power Supply Load Current 50 Amp (rms) Surge Capability 625Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 180-280VAC Overvoltage Vpk 600V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Crydom PMP2450W or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
$197.00
$232.46 inclGST -
MCBC2450DF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 4-20mA Input, 10 Cycles
Crydom MCBC2450DF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 4-20mA Input, 10 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC2450DF Switching Type Burst Fire (10 Cycles) ROHS/CE/UL Yes Control Voltage 4 - 20mA Proportional Input Requires DC Power Supply Load Current 50 Amp (rms) Surge Capability 625Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 180-280VAC Overvoltage Vpk 600V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Crydom PMP2450W or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
$197.00
$232.46 inclGST -
MCBC4850DL, Solid Sate Relay based Burst Fire Controller, 480VAC, 50 Amp, 4-20mA Input, 20 Cycles
Crydom MCBC4850DL, Solid Sate Relay based Burst Fire Controller, 480VAC, 50 Amp, 4-20mA Input, 20 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC4850DL Switching Type Burst Fire (20 Cycles) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 50 Amp (rms) Surge Capability 625Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 330-550VAC Overvoltage Vpk 1200V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Crydom PMP2425W or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
$223.00
$263.14 inclGST -
MCBC2450CF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 0-10V Input, 10 Cycles
Crydom MCBC2450CF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 0-10V Input, 10 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC2450CF Switching Type Burst Fire (10 Cycles) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 50 Amp (rms) Surge Capability 625Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 180-280VAC Overvoltage Vpk 600V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Crydom PMP2425W or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
$197.00
$232.46 inclGST -
HS211 + RS1API420MA280040R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps
HS211 + RS1API420MA280040R Proportional Phase Control Solid State Relays + Heatsink 4-20mA Proportional Phase Control Input Ratings from 25A to 80 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Part Number HS211 + RS1API420MA280040R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 27 Amp (rms) @ 40 Deg C Surge Capability 500 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211A_B HS211 RS1A Series Product Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here
$131.00
$154.58 inclGST -
HS211 + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps
HS211 + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps 4-20mA Proportional Phase Control Input Ratings from 25A to 80 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Specification Part Number HS211 + RS1API420MA280025R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 25 Amp (rms) @ 40 Deg C Surge Capability 240 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style DIN Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211A_B HS211 RS1A Series Product Notifications Pease note Changes from Gen 3 to Gen 4 (current) package design here
$131.00
$154.58 inclGST