Panel Mount kWh Meters

46 products

  • Cube 400-M2, Panel Mount kWh Meter, 3 Phase, Class 1, 5Amp input, 240VAC aux, w/ pulse output

    Cube 400-M2, Panel Mount kWh Meter, 3 Phase, Class 1, 5Amp input, 240VAC aux, w/ pulse output

    15 pcs in stock

    Northern Design Cube 400-M2 Series 3 Phase Power Meter Optional 2 Pulse Input or Outputs Nominal current up to 6 A (For 5A CT Input) and nominal voltage up to 240V L-N Three Line Display Optional RS 232/RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Optional THD up to 15th Harmonic The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 1 Simple Menu Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication MODBUS and Ethernet communication protocol 240V AC power supply Specification Northern Design Part Number Cube 400-M2 Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 415V L-L 240V L-N, 5 Amp Maximum Measurement Range 415V L-L 280V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 1 (kW,kWh) Class 1(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A (Optional 2400-19200 b/s) Weight 350g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Product Manual Product Comms Manual Application Notes Dual Tariff Guide CT Cable Losses Meter Accuracy at Low Current Current Input Isolation

    15 pcs in stock

    $584.00
    $689.12 inclGST

  • Smart X72-5F, Panel Mount Multifuction Meter, Class 0.5S, 50-480VAC, 1A/5A CT input, 30 Parameter, Modbus RTU RS485 Comms, Self Powered

    Smart X72-5F, Panel Mount Multifuction Meter, Class 0.5S, 50-480VAC, 1A/5A CT input, 30 Parameter, Modbus RTU RS485 Comms, Self Powered

    6 pcs in stock

    Eastron Smart X72-5F, Panel Mount Multifuction Meter, Class 0.5S, 50-480VAC, 1A/5A CT input, 30 Parameter, Modbus RTU RS485 Comms, Self Powered Metering and Numerical Display Adjustable tariff clock (Optional 4 Tarriffs), display of electric energy consumption in optional currency Optional 2 x Pulse Outputs Modbus RTU as standard True RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values of more than 30 quantities (U, I, P, THD, IHD, S, PF, PA, f, f, MD, etc.). Accuracy class 1 Optional 2 or 4 tariff inputs, Digital Output and Input Ethernet communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD with Dual Metering and PF Displays Specification Eastron Part Number Smart X72-5F Functions Power Quality Meter, Energy Meter Aux Supply 65-276VAC/90-380VDC Nominal Measurement Range 50-480V L-L, 1/5 Amp Maximum Measurement Range 480V L-L, 1/5 Amp Pulse Outputs Optional (see Smart X72-5G) Alarm 2 x Digital Outputs (shared with Pulse function) Tariff Input 1 (Optional see Smart X72-5G) Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 2.5kV (1 Min) RS485 2400-38400 b/s Weight 500g Certification MID, UL Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Operating Temperature -25 →+55 °C   Datasheet User Manual

    6 pcs in stock

    $315.00
    $371.70 inclGST

  • Northern Design Electronics Ltd kWh Meter Cube 400-M2-C, Panel Mount kWh Meter, Class 1, 5Amp input, 2 pulse inputs or alarm/pulse outputs, RS485 Comms, Three line LCD Display FE-CUBE400-M2-C

    Cube 400-M2-C, Panel Mount kWh Meter, Class 1, 5Amp input, 2 pulse inputs or alarm/pulse outputs, RS485 Comms, Three line LCD Display

    15 pcs in stock

    Northern Design Cube 400-M2-C Series 3 Phase Power Meter Optional 2 Pulse Input or Outputs Nominal current up to 6 A (For 5A CT Input) and nominal voltage up to 240V L-N Three Line Display Optional RS 232/RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Optional THD up to 15th Harmonic The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 1 Simple Menu Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication MODBUS and Ethernet communication protocol 240V AC power supply Specification Northern Design Part Number Cube 400-M2-C Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 415V L-L 240V L-N, 5 Amp Maximum Measurement Range 415V L-L 280V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 1 (kW,kWh) Class 1(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Ethernet Modbus RTU Over TCP/IP 2400-19200 b/s Weight 350g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Product Manual Product Comms Manual Application Notes Dual Tariff Guide CT Cable Losses Meter Accuracy at Low Current Current Input Isolation

    15 pcs in stock

    $598.00
    $705.64 inclGST

  • Smart X96-5-MID, Panel Mount Multifuction Meter, Class 1, 173-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, Modbus RTU RS485 Comms, Self Powered, MID Approved

    Smart X96-5-MID, Panel Mount Multifuction Meter, Class 1, 173-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, Modbus RTU RS485 Comms, Self Powered, MID Approved

    16 pcs in stock

    Eastron Smart X96-5-MID, Panel Mount Multifuction Meter, Class 1, 173-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, Modbus RTU RS485 Comms, Self Powered, MID Approved Metering and Numerical Display Adjustable tariff clock (Optional 4 Tarriffs), display of electric energy consumption in optional currency Modbus RTU as standard True RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values of more than 30 quantities (U, I, P, THD, IHD, S, PF, PA, f, f, MD, etc.). Accuracy class 1 Optional 2 or 4 tariff inputs, Digital Output and Input Ethernet communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD with Dual Metering and PF Displays Specification Eastron Part Number Smart X96-5-MID Functions Power Quality Meter, Energy Meter Aux Supply Through Measurement Inputs Nominal Measurement Range 173-480V L-N, 1/5 Amp Maximum Measurement Range 280V L-N, 1/5 Amp Pulse Outputs 2 x Digital Outputs (shared with Alarm function) Alarm 2 x Digital Outputs (shared with Pulse function) Tariff Input 1 (Optional 4 x ) Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 2.5kV (1 Min) RS485 2400-38400 b/s Weight 500g Certification MID, UL Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Operating Temperature -25 →+55 °C   Datasheet Product Datasheet User Manual Modbus Registers

    16 pcs in stock

    $385.00
    $454.30 inclGST

  • LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display

    LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display

    22 pcs in stock

    Risbabh LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display 2 Pulse Outputs Nominal current up to 1.2/6 A (For 1/5A CT Input) and nominal voltage up to 240V L-N Three Section Display RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor THD up to 31sth Harmonic 85 Parameter Measurement The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 0.2 Simple Menu RS 485 communication up to 19,200 bit/s MODBUS communication protocol 240V AC power supply Specification Rishabh Part Number LM1360-MA4L-4-3-01-02-R-H-2 Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 600V L-L 350V L-N, 5 Amp Maximum Measurement Range 600V L-L 350V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 0.2S (kW,kWh) Class 0.5(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Ethernet Modbus RTU Over TCP/IP 2400-19200 b/s Weight 450g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software Software User Manual Software Download Link Application Notes 1)Reading Data from Registers -> Download file 2)Maximum Memory Size -> Read below Max Available Memory Locations in 8MB Size = 273030 Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user Considering your example for 2 parameters: Number of parameter selected by user = 2 (kwh & kVA) Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log) Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257 Timelog Interval setting = 15 minutes Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.

    22 pcs in stock

    $309.00
    $364.62 inclGST

  • Last stock! MC350H S ARNG SJUNNAT, Panel Mount Network Recorder with Harmonics (31st), Class 1, 50..500VAC 50/60Hz 61 Parameter Measurement, Universal 20..300V DC, 48..276VAC Aux, 8MB Logging Memory-kWh Meter-Iskra Doo-Fastron Electronics Store

    MC350H S ARNG SUNNAT, Panel Mount Network Recorder with Harmonics (31st), Class 1, 50..500VAC 50/60Hz 61 Parameter Measurement, Universal 20..300V DC, 48..276VAC Aux, 8MB Logging Memory

    2 pcs in stock

    MC350H S ARNG SUNNAT, Panel Mount Network Recorder with Harmonics (31st), Class 1, 50..500VAC 50/60Hz 61 Parameter Measurement, Universal 20..300V DC, 48..276VAC  Aux, 8MB Logging Memory Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Includes Harmonics Accuracy class 0.5 Measurement of 20 minimal and maximal values in different time periods Optional dual tariff inputs and pulse or relay outputs Wide frequency range from 16 Hz to 400 Hz RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 600 V Multilingual support User-friendly PC MiQen software Specification Iskra Doo Part Number MC350H S ARNG SUNNAT Functions Power Quality Meter, Energy Meter Supply Voltage Universal 20..300V DC, 48..276VAC Nominal Measurement Range 500V L-N, 5 Amp  50/60Hz Maximum Measurement Range 600V L-N, 12.5 Amp   50/60Hz Alarm Optional 2 Relay/Pulse Outputs Tariff/Digital Inputs Optional 2 x Digital or Tarrif Inputs Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional 2 x Programmable Analogue Outputs Internal Memory 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Through Hole CT Weight 500g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet User Manual  

    2 pcs in stock

    $675.00
    $796.50 inclGST

  • Cube 300-M2-C, Panel Mount kWh Meter, Class 1, 5Amp input, 2 pulse inputs or alarm/pulse outputs, RS485 Comms, Single line LCD Display

    Cube 300-M2-C, Panel Mount kWh Meter, Class 1, 5Amp input, 2 pulse inputs or alarm/pulse outputs, RS485 Comms, Single line LCD Display

    Out of stock

    Northern Design Cube 300-M2-C Series 3 Phase Power Meter 2 Pulse Input or Outputs Nominal current up to 6 A (For 5A CT Input) and nominal voltage up to 240V L-N Single Line Display Optional RS232/RS485 communication up to 19,200 bit/s True RMS measurement of currents and voltages The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, harmonics, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 1 Simple Menu Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication MODBUS communication protocol 240V AC power supply Specification Northern Design Part Number Cube 300-M2-C Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 240V L-N, 5 Amp Maximum Measurement Range 280V L-N, 6 Amp Display Single Line LCD Pulse Output 2 (input or output) Accuracy Class 1 (kW,kWh) Class 1(Active) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 2400-19200 b/s Weight 250g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Product Manual Product Comms Manual Application Notes Dual Tariff Guide

    Out of stock

    $279.00
    $329.22 inclGST

  • Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Out of stock

    Secure Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Dual Loggers, configurable for Instant or accumulated energy Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500C-5202 Functions Power Quality Meter (31st Hamonic), Energy Meter, Network Recorder Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 1/5 Amp, 415V L-L 1/5 Amp Maximum Measurement Range 300V L-N, 1/5 Amp, 500V L-L 1/5 Amp Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Cross Reference  The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300   ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650   ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760   ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330   ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60   PM 5560   ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60   DM6200H   ACCUVIM-EL (+ IEC 61850)     PM2220   ACCUVIM-II R +Ethernet     PM2230 / DM2120 (LED)         PM 5350        

    Out of stock

    $725.00
    $855.50 inclGST

  • Smart X72-5G, Panel Mount Multifuction Meter, Class 0.5S, 50-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, 4 Digital Inputs, Modbus RTU RS485 Comms, Self Powered

    Smart X72-5G, Panel Mount Multifuction Meter, Class 0.5S, 50-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, 4 Digital Inputs, Modbus RTU RS485 Comms, Self Powered

    6 pcs in stock

    Eastron Smart X72-5G, Panel Mount Multifuction Meter, Class 0.5S, 50-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, 4 Digital/Tariff Inputs, Modbus RTU RS485 Comms, Self Powered Metering and Numerical Display Adjustable tariff clock (Optional 4 Tariffs), display of electric energy consumption in optional currency Modbus RTU as standard True RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values of more than 30 quantities (U, I, P, THD, IHD, S, PF, PA, f, f, MD, etc.). Accuracy class 1 Optional 2 or 4 tariff inputs, Digital Output and Input Ethernet communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD with Dual Metering and PF Displays Specification Eastron Part Number Smart X72-5G Functions Power Quality Meter, Energy Meter Aux Supply 65-276VAC/90-380VDC Nominal Measurement Range 50-480V L-L, 1/5 Amp Maximum Measurement Range 480V L-L, 1/5 Amp Pulse Outputs 2 x Shared with Digital outputs Alarm 2 x Digital Outputs (shared with Pulse function) Tariff Input 4 Digital Inputs Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 2.5kV (1 Min) RS485 2400-38400 b/s Weight 500g Certification MID, UL Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Operating Temperature -25 →+55 °C   Datasheet User Manual

    6 pcs in stock

    $345.00
    $407.10 inclGST

  • E500M-3012, 3 Analogue Output Module for Secure, Elite 500 Series E500M-3012, 3 Analogue Output Module for Secure, Elite 500 Series

    E500M-3012, 3 Analogue Output Module for Secure, Elite 500 Series

    Out of stock

    Elite E500M-3012, 3 Analogue Output Module for Secure, Elite 500 Series   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software

    Out of stock

    $149.00
    $175.82 inclGST

  • E500M-2022, 3 Relay Output Module for Secure, Elite 500 Series E500M-2022, 3 Relay Output Module for Secure, Elite 500 Series

    E500M-2022, 3 Relay Output Module for Secure, Elite 500 Series

    Out of stock

    Elite E500M-2012, 3 Relay Output Module for Secure, Elite 500 Series   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software

    Out of stock

    $149.00
    $175.82 inclGST

  • E500M-2012, Configurable Pulse Input Output Module for Secure, Elite 500 Series E500M-2012, Configurable Pulse Input Output Module for Secure, Elite 500 Series

    E500M-2012, Configurable Pulse Input Output Module for Secure, Elite 500 Series

    Out of stock

    Elite E500M-2012, Configurable Pulse Input Output Module for Secure, Elite 500 Series   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software

    Out of stock

    $149.00
    $175.82 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account