Moulded Case Circuit Breakers (MCCB)
-
FGM6SM-4P-160M 80A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=36kA 40 Amp, 400/690VAC
Trent FGM6SM-4P-160M 80A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 36kA 80 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-160M 80A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 80 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$205.00
$241.90 inclGST -
FGM6SM-4P-160M 63A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=36kA 63 Amp, 400/690VAC
Trent MOD1 3NM 63A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 36kA 63 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-160M 63A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 63 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$179.00
$211.22 inclGST -
FGM6SMM-4P-800H-800A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Fixed Type ICS=75kA 800 Amp, 400/690VAC
Trent FGM6SM-4P-630H 1000A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Fixed Type 75kA 800 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-630H 1000A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 800 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 16kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$1,015.00
$1,197.70 inclGST -
FGM6SMM-4P-800H 700A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Fixed Type ICS=75kA 700 Amp, 400/690VAC
Trent FGM6SM-4P-630H 1250A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Fixed Type 75kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-630H 1250A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 85kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 16kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$1,015.00
$1,197.70 inclGST -
FGM6SM-4P-250H 125A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Fixed Type ICS=36kA 125 Amp, 400/690VAC
Trent FGM6SM-4P-250H 125A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Fixed Type 36kA 125 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-250H 125A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 125 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 36kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$199.00
$234.82 inclGST -
FGM6SM-4P-800H 700A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=75kA 700 Amp, 400/690VAC
Trent FGM6SM-4P-800H 700A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 75kA 700 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-800H 700A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 700 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 8.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$1,199.00
$1,414.82 inclGST -
FGM6SM-4P-800H 800A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type ICS=75kA 800 Amp, 400/690VAC
Trent FGM6SM-4P-800H 800A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic, Adjustable Type 75kA 800 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 4 Pole Disconnect 75kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6SM-4P-800H 800A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 800 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 75kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 8.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$1,199.00
$1,414.82 inclGST -
FGM6-3P-1250M 1000A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=50kA 1000 Amp, 400/690VAC
Trent FGM6-3P-1250M 1000A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 50kA 1000 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1250M 1000A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1000 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 10.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$1,299.00
$1,532.82 inclGST -
FGM6-3P-1250M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=50kA 1250 Amp, 400/690VAC
Trent FGM6-3P-1250M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 50kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 50kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1250M 1250A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 50kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 10.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$1,299.00
$1,532.82 inclGST -
FGM6-3P-1600M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=65kA 1250 Amp, 400/690VAC
Trent FGM6-3P-1600M 1250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 65kA 1250 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 65kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1600M 1250A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1250 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 65kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 12.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$1,499.00
$1,768.82 inclGST -
FGM6-3P-1600M 1600A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=65kA 1600 Amp, 400/690VAC
Trent FGM6-3P-1600M 1600A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 65kA 1600 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 3 Pole Disconnect 65kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-3P-1600M 1600A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1600 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 65kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 12.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$1,499.00
$1,768.82 inclGST -
FGM6-4P-1600M 1600A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type ICS=65kA 1600 Amp, 400/690VAC
Trent FGM6-4P-1600M 1600A, 4 Pole Moulded Case Circuit Breaker (MCCB) Thermal & Magnetic, Fixed Type 65kA 1600 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a dis connector in case of electric shock Features : 4 Pole Disconnect 65kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGM6-4P-1600M 1600A Functions 4 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 1600 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current 65kA Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 12.9kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$1,499.00
$1,768.82 inclGST