Motor Control
-
FGC3-D323, Star-Delta Reduced Voltage starter, 240/400/500/690V, Nominal Current = 32 Amps (AC-3), 50/60Hz Operation, 230VAC Coil Voltage, 3 Pole 3 x NO + 1NO
Fastron Electronics FGC3-D323, Star-Delta Reduced Voltage starter, 240/400/500/690V, Nominal Current = 32 Amps (AC-3), 50/60Hz Operation, 230VAC Coil Voltage, 3 Pole 3 x NO + 1NO Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp CE, CB Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Fastron Electronics Part Number FGC3-D323 Functions 3 Pole NO + 1NO 1NC Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 32 Amp Continuous @ 55 Deg C Main Contacts 3 x NO Auxiliary Contacts 1 x NO Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 2.3W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 900g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$398.00
$469.64 inclGST -
FGC2-D32-230VAC, Interlocking AC Contactor / Motor Reverser, 240VAC Control Voltage, 3 Pole 3 x NO , 3 x NC + 1NO1NC Aux, Nominal Current = 32 Amps(AC-3) @ 240/400/500/690V
Fastron Electronics FGC2-D32-230VAC, Interlocking AC Contactor / Motor Reverser, 240VAC Control Voltage, 3 Pole 3 x NO , 3 x NC + 1NO1NC Aux, Nominal Current = 32 Amps(AC-3) @ 240/400/500/690V Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp CE, CB Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Fastron Electronics Part Number FGC2-D32-230VAC Functions 3 Pole (x2) + 1NO 1NC Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 32 Amp Continuous @ 55 Deg C Main Contacts 3 x NO, 3 x NC Auxiliary Contacts 1 x NO, 1 x NC Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 2.3W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 600g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$398.00
$469.64 inclGST -
GXV600P, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC EXTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67
Gigavac GXV600P, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC EXTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved 12/24VDC Internal or External PWM Coils Flexible package for installation Specification Gigavac Part Number GXV600P Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 12/24VDC External PWM Load Current 600+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals JST Connector: 02CPT-B-2A JST Terminal: SCPT-A021GF-0.5 Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 12 - 900VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet
$369.00
$435.42 inclGST -
GXV600M, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC INTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67
Gigavac GXV600M, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC INTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved 12/24VDC Internal or External PWM Coils Flexible package for installation Specification Gigavac Part Number GXV600M Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 12/24VDC Internal PWM Load Current 600+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals JST Connector: 02CPT-B-2A JST Terminal: SCPT-A021GF-0.5 Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 12 - 900VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet
$369.00
$435.42 inclGST -
DRC3R40E420, AC Motor Controller & Contactor, 7.6 Amp, 18-30VDC control, 48-440VAC Load, 2 Solid State NO Aux Contacts, Zero Crossing
Crydom DRC3R40E420, AC Motor Controller & Contactor, 7.6 Amp, 18-30VDC control, 48-530VAC Load, 2 Solid State NO Aux Contacts, Zero Crossing Features 7.6 Amp AC Semiconductor Motor Controller Load voltage range up to 600VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) Spec Crydom Part Number DRC3R40E420 Switching Type DC Load Approvals ROHS,UL,CE,IEC Control Voltage 18-30VDC Load Current 7.6 Amp (rms) Surge Capability (10ms) 716 Amp (peak) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 48-440VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 197g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$347.28
$409.79 inclGST -
LX9043 (11.212.309 AMJ5552 MAHLE REPLICA), DC Motor, 12VDC, 2.1kW 2000rpm CW Direction
LX9043 (11.212.309 AMJ5552 MAHLE REPLICA), DC Motor, 12VDC, 2.1kW 2000rpm CW Direction. MAHLE Specification ISKRA (MAHLE) Part Number 11.212.309, AMJ5552, MAHLE REPLICA ISKRA/LETRIKA/MAHLE IM0012, 11212309, AMJ5552, MM64 Voltage 12VDC Power 1.6kW Rotation Unidirectional Clockwise Rotation Speed 2350 rpm Unit Weight 7.2kg Factory Pack Qty 1 Cross Reference Manufacturer Manufacturer P/N BUCHER HYDRAULICS (HIDROIRMA) 200 5439 13901 BUCHER HYDRAULICS (HIDROIRMA) 543 913 901 FLUITRONICS (BERENDSEN) 1239682 FLUITRONICS (BERENDSEN) 9000425602 Manufacturer BUCHER HYDRAULICS (HIDROIRMA) FLUITRONICS (BERENDSEN) Spare Parts Spare Parts Page
$898.00
$1,059.64 inclGST -
11.212.309 AMJ5552 MAHLE, DC Motor, 12VDC, 2.1kW 2000rpm CW Direction
11.212.309 AMJ5552, MAHLE Letrika(Iskra) DC Motor, 12VDC, 2.1kW 2000rpm CW Direction 11212309, AMJ5552, MM64 Specification ISKRA (MAHLE) Part Number 11.212.309, AMJ5552, MAHLE ISKRA/LETRIKA/MAHLE IM0012, 11212309, AMJ5552, MM64 Voltage 12VDC Power 2.1kW Rotation Unidirectional Clockwise Rotation Speed 2000 rpm Unit Weight 7.2kg Factory Pack Qty 1 Cross Reference Manufacturer Manufacturer P/N BUCHER HYDRAULICS (HIDROIRMA) 200 5439 13901 BUCHER HYDRAULICS (HIDROIRMA) 543 913 901 FLUITRONICS (BERENDSEN) 1239682 FLUITRONICS (BERENDSEN) 9000425602 Manufacturer BUCHER HYDRAULICS (HIDROIRMA) FLUITRONICS (BERENDSEN) Spare Parts Spare Parts Page
$1,095.05
$1,292.16 inclGST -
FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release
Trent FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M21 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 17 - 23 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$68.00
$80.24 inclGST -
FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp
Trent FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-MAN20 Functions Auxiliary Contact Nominal Voltage 230/400VAC @ 50/60Hz Configuration 1 x NO 1 x NC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$12.00
$14.16 inclGST -
FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp
Trent FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-MAN11 Functions Auxiliary Contact Nominal Voltage 230/400VAC @ 50/60Hz Configuration 1 x NO 1 x NC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$12.00
$14.16 inclGST -
FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp
Trent FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M AU400 Functions Shunt Trip/Voltage Release Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0-6 Amp (Ith) Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Release Voltage 385-415VAC Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$12.00
$14.16 inclGST -
FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp
Trent FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M AU225 Functions Shunt Trip/Voltage Release Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0-6 Amp (Ith) Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Release Voltage 220-240VAC Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$12.00
$14.16 inclGST