Magnelab 5 Amp Rogowski Coils for wholesale pricing
-
RCS-1805-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 6 Inch Diameter Rogowski Coils with Integrator
RCS-1805-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 6 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System: The RCS-1805 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp. A 24VDC Power Supply is included to operate these coils. The RCS-1805 comes with 5 Amp integrator.. Included is an 18 inch circumference rope CT with Integrator, and power supply. Magnelab Coils come with 10 year warranty  Specification Magnelab Part Number RCS-1805-VAR Function AC Current Measurement Nominal Measurement Current (Ipn) 500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable Measurement Range 10% - 130% if Ipn Output Range 0-5Amp Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 24VDC Accuracy 1% from 25 to 5000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 6 Inch Coil Circumference 18 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 2200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS-VAR Series Installation Guide
$1,874.00
$2,211.32 inclGST -
RCS-2405-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 8 Inch Diameter Rogowski Coils with Integrator
RCS-2405-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 8 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils): The RCS-2405 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp. A 24VDC Power Supply is included to operate these coils. The RCS-2405 comes with 5 Amp integrator.. Included is an 24 inch circumference rope CT with Integrator, and power supply. Magnelab Coils come with 10 year warranty  Specification Magnelab Part Number RCS-2405-VAR Function AC Current Measurement Nominal Measurement Current (Ipn) 500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable Measurement Range 10% - 130% if Ipn Output Range 0-5 Amp Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 24VDC Accuracy 1% from 25 to 5000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 8 Inch Coil Circumference 24 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 2500g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS-VAR Series Installation Guide
$1,938.00
$2,286.84 inclGST -
RCS-1205-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 4 Inch Diameter Rogowski Coils with Integrator
RCS-1205-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 4 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System: The RCS-1205 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp. A 24VDC Power Supply is included to operate these coils. The RCS-1205 comes with 5 Amp integrator.. Included is an 12 inch circumference rope CT with Integrator, and power supply. Magnelab Coils come with 10 year warranty  Specification Magnelab Part Number RCS-1205-VAR Function AC Current Measurement Nominal Measurement Current (Ipn) 500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable Measurement Range 10% - 130% if Ipn Outptu Range 0-5 Amp Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 24VDC Accuracy 1% from 25 to 5000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 4 Inch Coil Circumference 12 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 2000g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS-VAR Series Installation Guide
$1,792.00
$2,114.56 inclGST -
RCS-3605-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 12 Inch Diameter Rogowski Coils with Integrator
RCS-3605-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 12 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils): The RCS-3605 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp. A 24VDC Power Supply is included to operate these coils. The RCS-3605 comes with 5 Amp integrator.. Included is an 36 inch circumference rope CT with Integrator, and power supply. Magnelab Coils come with 10 year warranty  Specification Magnelab Part Number RCS-3605-VAR Function AC Current Measurement Nominal Measurement Current (Ipn) 500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable Measurement Range 10% - 130% if Ipn Output Range 0-5 Amp Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 24VDC Accuracy 1% from 25 to 5000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 12 Inch Coil Circumference 36 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 3500g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS-VAR Series Installation Guide
$2,046.00
$2,414.28 inclGST -
RCS-4805-VAR, 5 Amp Output, Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 16 Inch Diameter Rogowski Coils with Integrator
RCS-4805-VAR, 5 Amp Output, Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 16 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils): The RCS-4805 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp. A 24VDC Power Supply is included to operate these coils. The RCS-4805 comes with 5 Amp integrator.. Included is an 48 inch circumference, 16 inch diameter rope CT with Integrator, and power supply. Magnelab Coils come with 10 year warranty  Specification Magnelab Part Number RCS-4805-VAR Function AC Current Measurement Nominal Measurement Current (Ipn) 500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable Measurement Range 10% - 130% if Ipn Output Range 0-5 Amp Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 24VDC Accuracy 1% from 25 to 5000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 16 Inch Coil Circumference 48 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 3500g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS-VAR Series Installation Guide
$2,274.00
$2,683.32 inclGST