Low Voltage Switchgear

167 products

  • PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage

    PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage

    9 pcs in stock

    Iskra Doo PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number PS11 Functions Auxiliary Contact for 3 Phase Motor Protection Switch, 1 x NO 6 Amp @ 230VAC, 1 x NC 6 Amp @ 230VAC Nominal Voltage 230VAC @ 50/60Hz Nominal Current Range 6 Amp RMS @230VAC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity N/A Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    9 pcs in stock

    $18.00
    $21.24 inclGST

  • 4400.0271 T11-211-6.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 6.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0271 T11-211-6.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 6.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    Out of stock

    4400.0271 T11-211-6.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 6.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0271 T11-211-6.5 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 6.5 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $18.00
    $21.24 inclGST

  • 4400.0232 T11-211-7.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 7.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0232 T11-211-7.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 7.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    58 pcs in stock

    4400.0232 T11-211-7.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 7.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0232 T11-211-7.5 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 7.5 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    58 pcs in stock

    $18.00
    $21.24 inclGST

  • 4400.0131 T11-211-0.6, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.6 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0131 T11-211-0.6, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.6 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    99 pcs in stock

    4400.0131 T11-211-0.6, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.6 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0131 T11-211-0.6 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 6 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    99 pcs in stock

    $18.00
    $21.24 inclGST

  • 4400.0129 T11-211-10.235, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 10.235 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0129 T11-211-10.235, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 10.235 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    Out of stock

    4400.0129 T11-211-10.235, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 10.235 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0129 T11-211-10.235 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 10.235 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $18.00
    $21.24 inclGST

  • Last stock! 4400.0114 T11-811-5, Thermal Circuit Breaker for Electrical Appliance, 240VAC/48VDC, 5 Amp, 1kA, Drop In Type, Reset Type, Quick Connect Terminals

    4400.0114 T11-811-5, Thermal Circuit Breaker for Electrical Appliance, 240VAC/48VDC, 5 Amp, 1kA, Drop In Type, Reset Type, Quick Connect Terminals

    1 pcs in stock

    4400.0114 T11-811-5, Thermal Circuit Breaker for Electrical Appliance, 240VAC/48VDC, 5 Amp, 1kA, Drop In Type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0114 T11-811-5 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 5 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    1 pcs in stock

    $18.00
    $21.24 inclGST

  • 4400.0102 T11-211-2.8, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 2.8 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0102 T11-211-2.8, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 2.8 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    Out of stock

    4400.0102 T11-211-2.8, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 2.8 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0102 T11-211-2.8 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 2.8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $18.00
    $21.24 inclGST

  • 4400.0101 T11-211-14, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 14 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0101 T11-211-14, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 14 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    100 pcs in stock

    4400.0101 T11-211-14, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 14 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0101 T11-211-14 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 14 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    100 pcs in stock

    $18.00
    $21.24 inclGST

  • 4400.0100 T11-211-13, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 13 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0100 T11-211-13, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 13 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    70 pcs in stock

    4400.0100 T11-211-13, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 13 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0100 T11-211-13 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 13 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    70 pcs in stock

    $18.00
    $21.24 inclGST

  • 4400.0084 T11-211-0.7, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.7 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0084 T11-211-0.7, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.7 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    100 pcs in stock

    4400.0084T11-211-0.7 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.7 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0084T11-211-0.7 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 0.7 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    100 pcs in stock

    $18.00
    $21.24 inclGST

  • 4400.0069 T11-211-0.4, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.4 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0069 T11-211-0.4, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.4 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    Out of stock

    4400.0069 T11-211-0.4, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.4 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0069 T11-211-0.4 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 0.4 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $18.00
    $21.24 inclGST

  • 4400.0059 T11-211-0.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0059 T11-211-0.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    Out of stock

    4400.0059 T11-211-0.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0059 T11-211-0.5 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 0.5 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $18.00
    $21.24 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account