Low Voltage Switchgear
-
FRS4-C40 385V 1P (1+0) (R), Class II/Type 2, AC Surge Protection Device (SPD), Un = 320VAC, Uc = 385VAC, 1 Pole In = 20/50kA L-N, L/N-PE, DIN Rail Mount, High Energy MOV Type, with Remote Contacts
Free Aus Post Shipping for $300 SpendTrent FRS4-C40 385V 1P (1+0) (R), Class II/Type 2, AC Surge Protection Device (SPD), Un = 320VAC, Uc = 385VAC, 1 Pole In = 20/50kA L-N, L/N-PE, DIN Rail Mount, High Energy MOV Type, with Remote Contacts Specifications Trent part number FRS4-C40 385V 1P (1+0) (R) Nominal Voltage (Un) 320VAC Maximum Operating Voltage (Uc( 385VAC Voltage Protection Level (Up) <1.5kV No of Poles 1 Category IEC / EN / VDE Class II / Type 2 Location of use Sub Distribution Boards Protection modes L/N-PE, High Energy MOV Additional Remote Contacts YES Protective element MOV Surge discharge rating Imax up to 40kA(8/20us) L/N-PE 385VAC Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
-
FRS4-C40 320V 1P (1+0) (R), Class II/Type 2, AC Surge Protection Device (SPD), 1 Pole In = 20/50kA L-N, L/N-PE, Un = 230VAC, Uc = 320VAC, DIN Rail Mount, High Energy MOV Type, with Remote Contacts
Trent FRS4-C40 320V 1P (1+0) (R), Class II/Type 2, AC Surge Protection Device (SPD), 1 Pole In = 20/50kA L-N, L/N-PE, Un = 230VAC, Uc = 320VAC, DIN Rail Mount, High Energy MOV Type, with Remote Contacts Specifications Trent part number FRS4-C40 230V 1P (1+0) (R) Nominal Voltage (Un) 230VAC Maximum Operating Voltage (Uc( 320VAC Voltage Protection Level (Up) <1.5kV No of Poles 1 Category IEC / EN / VDE Class II / Type 2 Location of use Sub Distribution Boards Protection modes L/N-PE, High Energy MOV Additional Remote Contacts YES Protective element MOV Surge discharge rating Imax up to 40kA(8/20us) L/N-PE 320VAC Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
$39.00
$46.02 inclGST -
P-3L-18WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. 3 Phase, 18 Way, 80 Amp 8mm
P-3L-18WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. 3 Phase, 18 Way, 80 Amp 8mm
$39.00
$46.02 inclGST -
4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, with Aux contact, Screw Clamp Terminals, 2 x Ir_3000 Switching Cycle
4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, with Aux contact, Screw Clamp Terminals, 2 x Ir_3000 Switching Cycle Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 3000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0221 T13-211R-30 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 30 Amp RMS Aux Contact Yes Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$37.50
$44.25 inclGST -
4410.0074 T12-221-6, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 6 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals
Schurter 1 Pole, 6 Amp, 1kA Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, 4410.0074 T12-221-6 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0074 (T12-221-6) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 6 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$37.18
$43.87 inclGST -
4410.0015 T12-221-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals
Schurter, 1 Pole 10 Amp, 1kA Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals 4410.0015 T12-221-10 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0015 (T12-221-10) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 10 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$37.18
$43.87 inclGST -
P-1L-27WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. Single Phase, 1 Pole, 18 Way, 80 Amp 8mm
P-1L-27WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. Single Phase, 1 Pole, 18 Way, 80 Amp 8mm
$35.00
$41.30 inclGST -
FGS1-C/1-440-20, 440VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/1-440-20, 440VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/1-440-20 Nominal Voltage 440VAC No of Poles 1 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$35.00
$41.30 inclGST -
FGS1-C/1-385-20, 385VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/1-385-20, 385VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/1-385-20 Nominal Voltage 385VAC No of Poles 1 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$35.00
$41.30 inclGST -
FGS1-C/1-320-20, 320VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/1-320-20, 320VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/1-320-20 Nominal Voltage 320VAC No of Poles 1 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$35.00
$41.30 inclGST -
FGS1-C/1-275-20, 275VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)
FGS1-C/1-275-20, 275VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA Specifications Trent part number FGS1-C/1-275-20 Nominal Voltage 275VAC No of Poles 1 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$35.00
$41.30 inclGST -
4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles
4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a dis-connector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 3000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0221 T13-211R-30 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 30 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$34.50
$40.71 inclGST