  • 4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, with Aux contact, Screw Clamp Terminals, 2 x Ir_3000 Switching Cycle

    4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, with Aux contact, Screw Clamp Terminals, 2 x Ir_3000 Switching Cycle

    Out of stock

    4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, with Aux contact, Screw Clamp Terminals, 2 x Ir_3000 Switching Cycle Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 3000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0221 T13-211R-30 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 30 Amp RMS Aux Contact Yes Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $37.50
    $44.25 inclGST

  • 4410.0074 T12-221-6, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 6 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals-Circuit Breaker-Schurter-Fastron Electronics Store

    4410.0074 T12-221-6, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 6 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals

    12 pcs in stock

    Schurter 1 Pole, 6 Amp, 1kA Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, 4410.0074 T12-221-6 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0074 (T12-221-6) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 6 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    12 pcs in stock

    $37.18
    $43.87 inclGST

  • 4410.0015 T12-221-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals-Circuit Breaker-Schurter-Fastron Electronics Store

    4410.0015 T12-221-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals

    8 pcs in stock

    Schurter, 1 Pole 10 Amp, 1kA Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals 4410.0015 T12-221-10 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0015 (T12-221-10) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 10 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    8 pcs in stock

    $37.18
    $43.87 inclGST

  • P-1L-27WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. Single Phase, 1 Pole, 18 Way, 80 Amp 8mm

    P-1L-27WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. Single Phase, 1 Pole, 18 Way, 80 Amp 8mm

    100 pcs in stock

    P-1L-27WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. Single Phase, 1 Pole, 18 Way, 80 Amp 8mm

    100 pcs in stock

    $35.00
    $41.30 inclGST

  • FGS1-C/1-440-20, 440VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)

    FGS1-C/1-440-20, 440VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)

    Out of stock

    FGS1-C/1-440-20, 440VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA     Specifications   Trent part number FGS1-C/1-440-20 Nominal Voltage 440VAC No of Poles 1 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11   Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester

    Out of stock

    $35.00
    $41.30 inclGST

  • FGS1-C/1-385-20, 385VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)

    FGS1-C/1-385-20, 385VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)

    Out of stock

    FGS1-C/1-385-20, 385VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA     Specifications   Trent part number FGS1-C/1-385-20 Nominal Voltage 385VAC No of Poles 1 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11   Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester

    Out of stock

    $35.00
    $41.30 inclGST

  • FGS1-C/1-320-20, 320VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)

    FGS1-C/1-320-20, 320VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)

    Out of stock

    FGS1-C/1-320-20, 320VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA     Specifications   Trent part number FGS1-C/1-320-20 Nominal Voltage 320VAC No of Poles 1 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11   Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester

    Out of stock

    $35.00
    $41.30 inclGST

  • FGS1-C/1-275-20, 275VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)

    FGS1-C/1-275-20, 275VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)

    Out of stock

    FGS1-C/1-275-20, 275VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA     Specifications   Trent part number FGS1-C/1-275-20 Nominal Voltage 275VAC No of Poles 1 Category IEC / EN / VDE Class II, Type 2 Location of use Sub Distribution Board Protection modes L-N,L-L Additional Remote Contacts NO Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Standards IEC50539-11   Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester

    Out of stock

    $35.00
    $41.30 inclGST

  • 4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles

    4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles

    Out of stock

    4400.0221 T13-211R-30, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 30 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a dis-connector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 3000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0221 T13-211R-30 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 30 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $34.50
    $40.71 inclGST

  • 4400.0043 T13-212-15, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 15 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles

    4400.0043 T13-212-15, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 15 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles

    Out of stock

    4400.0043, T13-212-15 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 15 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a dis-connector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 3000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0043 T13-212-15 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 15 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $34.50
    $40.71 inclGST

  • P-1L-18WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. Single Phase, 1 Pole, 18 Way, 80 Amp 8mm

    P-1L-18WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. Single Phase, 1 Pole, 18 Way, 80 Amp 8mm

    299 pcs in stock

    P-1L-18WAY-80A, Pin Type Busbar For Generic MCB or Modular Contactors. Single Phase, 1 Pole, 18 Way, 80 Amp 8mm

    299 pcs in stock

    $29.00
    $34.22 inclGST

  • Module ISPRO C 40/440, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 440VAC Module ISPRO C 40/440, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 440VAC

    Module ISPRO C 40/440, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 440VAC

    24 pcs in stock

    Iskra Module ISPRO C 40/440, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 440VAC, Class II / Type 2 / C Specifications   Iskra Doo part number Module ISPRO C 40/440 Nominal Voltage 440VAC No of Poles 1 Category IEC / EN / VDE Class II / Type 2 / C Location of use In ISPRO Products Protection modes L/N-PE Protective element MOV + GDT Surge discharge rating Imax up to 40 kA Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11   Datasheet Product Datasheet

    24 pcs in stock

    $27.00
    $31.86 inclGST