LEM Price Group #6A
-
HO 50-S-0100, O/L Hall Effect Current Sensor, 50 Amp, 15 x 8mm Aperture, Vref = 2.5V, Panel Mount
LEM HO 50-S-0100 Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for panel mounting Aperture: 15 × 8 mm Factory calibrated Repositionabel mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 50-S-0100 Technology Open Loop Hall Effect Aperture 15 x 8mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 50 Amp Measurement Range +/-125 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B5B-PH type Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$39.90
$47.08 inclGST -
HOYS 560-S-0100, O/L Hall Effect Current Sensor,560 Amp, 5VDC Supply, Panel Mount, 13 x 21.5mm Aperture, X = 1%
LEM HOYS 560-S-0100 Series Closed Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Voltage output Single supply +5 V Overcurrent detect 2.93 × IPN (peak value) Galvanic separation between primary and secondary circuit Low power consumption For busbar mounting Aperture: 21.5 × 13 mm Factory calibrated ● Mating JST connector: housing PAP-05V-S contact SPHD-00xT-P0.5. Advantages Low offset drift Over-drivable Vref Creepage / clearance > 10.5 mm Fast response Low profile 2 mm pitch connector for 22 to 28 AWG wire. Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 ● IEC 62109-1: 2010 ● UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HOYS 560-S-0100 Technology Open Loop Hall Effect Aperture 21.5 x 13mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 560 Amp Measurement Range +/-1400 Amp Output 2.5 Vref Isolation 5.4 kV Bandwidth DC-180 kHz Mounting Style Busbar Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B05B-PASK or equivalent Unit Weight 101g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$60.10
$70.92 inclGST -
HOYL 200-S-0100, Hall Effect Current Sensor, 200 Amp, 5VDC Supply, PCB Mount, 13 x 40mm Aperture, X = 1%
LEM HOYL 200-S-0100 Series Closed Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Voltage output Single supply +5 V Overcurrent detect 2.93 × IPN (peak value) Galvanic separation between primary and secondary circuit Low power consumption For busbar mounting Aperture: 40 × 13 mm Factory calibrated ? Mating JST connector: housing PAP-05V-S contact SPHD-00xT-P0.5. Advantages Low offset drift Over-drivable Vref Creepage / clearance > 10.5 mm Fast response Low profile 2 mm pitch connector for 22 to 28 AWG wire. Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HOYL 200-S-0100 Technology Open Loop Hall Effect Aperture 40 x 13mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 200 Amp Measurement Range +/-500 Amp Output 2.5 Vref Isolation 8 kV Bandwidth DC-140 kHz Mounting Style Busbar Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B05B-PASK or equivalent Unit Weight 232g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$140.72
$166.05 inclGST -
HO 100-S-0100, O/L Hall Effect Current Sensor, 100 Amp, 18.8 x 10.5mm Aperture, Panel Mount
LEM HO 100-S-0100 Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for panel mounting Aperture: 15 × 8 mm Factory calibrated Repositionabel mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 100-S-0100 Technology Open Loop Hall Effect Aperture 15 x 8mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 100 Amp Measurement Range +/-250 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B5B-PH type Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$44.20
$52.16 inclGST -
CTSR 0.3-P, C/L Hall Effect Current Transducer,Ipn = 300mA, 20.1mm round aperture, 2.5Vref out, 5VDC supply, X = 1.9%
CTSR 0.3-P, C/L Hall Effect Earth Leakage Current Sensor, 300mA Features DC & AC earth leakage current transducer using a flux-gate principle PCB mounting ±15V power supply ±5V output @ IPN Isolated plastic case recognized according to UL94-V0. Advantages Small size Wide Aperture Bandwidth : DC and 3.5 kHz Response time better than 50 ms Cost effective, compact alternative to classical RCDs (Residual Current Device) Applications Earth leakage detection in transformerless solar inverters 1st human contact protection of PV arrays Failure detection in power sources Symmetrical fault detection (e.g. after motor inverter) Current leakage detection in stacked DC sources Single phase or three phase differential current measurement up to ±30A per wire (DC or AC) Application Domains Industrial Specification LEM Part Number CTSR 0.3-P Technology Closed Loop Hall Effect ROHS Yes Supply Voltage +/-15VDC Load Current (RMS + DC) 300mA Output 2.5Vref Isolation 5.4kV Bandwidth DC-3.5kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Aperture ø 20.1mm Unit Weight 28g Factory Pack Qty 10 Datasheet Product Datasheet
$85.30
$100.65 inclGST -
HO 150-S/SP33-1106, O/L multi range Hall Effect Current Sensor, 150 Amp, Panel Mount, 18.8 x 10.5mm aperture, Panel Mount +3.3 V, Overcurrent Detection
LEM HO 150-S/SP33-1106, O/L multi range Hall Effect Current Sensor, 150 Amp, Panel Mount, 18.8 x 10.5mm aperture, Panel Mount +3.3 V, Overcurrent Detection Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single power supply +3.3 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for panel mounting Aperture: 15 × 8 mm Factory calibrated Repositionabel mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 100-S/SP33-1106 Technology Open Loop Hall Effect Aperture 15 x 8mm ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 250 Amp Measurement Range +/-625 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B5B-PH type Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$45.00
$53.10 inclGST -
HO 200-S/SP33-1106, O/L multi range Hall Effect Current Sensor, 200 Amp, Panel Mount, 18.8 x 10.5mm aperture, Digital Bitsream Output, Panel Mount +3.3 V, Overcurrent Detection
LEM HO 250-S/SP33-1106 Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single power supply +3.3 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for panel mounting Aperture: 15 × 8 mm Factory calibrated Repositionabel mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 250-S/SP33-1106 Technology Open Loop Hall Effect Aperture 15 x 8mm ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 200 Amp Measurement Range +/-500 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B5B-PH type Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$57.00
$67.26 inclGST -
HO 200-S-0100, O/L Hall Effect Current Sensor, 200 Amp, 15 x 8mm Aperture, Vref = 2.5V, Panel Mount
LEM HO 200-S-0100, O/L Hall Effect AC/DC Current Sensor, 200 Amp, 15 x 8mm Aperture, Vref = 2.5V, Panel Mount Features Open loop current transducer Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for panel mounting Aperture: 15 × 8 mm Factory calibrated Repositionabel mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 200-S-0100 Technology Open Loop Hall Effect Aperture 15 x 8mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 200 Amp Measurement Range +/-500 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B5B-PH type Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$57.00
$67.26 inclGST -
LA 125-P/SP4, C/L Hall Effect Current Sensor, 125 Amp, 62.5mA Output, 13 x 33.2mm Aperture, +/-12..15V Supply, PCB Mount, X = 0.6%
LEM LA 125-P/SP4 Series Closed Loop AC/DC Hall Effect Sensor Features SP4 = Potted Bandwidth DC to 150kHz Closed loop transducer using Hall effect Compact and versatile PCB Mounted with Strain Relief Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LA125-P/SP4 Technology Closed Loop Hall Effect Aperture 13 x 11mm ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 130 Amp Measurement Range +/-200 Amp Output 62.5 mA Isolation 3 kV Bandwidth DC-150 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 80°C Accuracy 0.6% Termination Style Through Hole PCB Unit Weight 35g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$178.30
$210.39 inclGST -
HO 50-S/SP33-1106, O/L Hall Effect Current Sensor, 250 Amp, 15 x 8mm Aperture, Vref = 1.65V, Panel Mount
LEM HO 50-S/SP33-1106, O/L Hall Effect Current Sensor, 250 Amp, 15 x 8mm Aperture, Vref = 1.65V, Panel Mount Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single power supply +3.3 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for panel mounting Aperture: 15 × 8 mm Factory calibrated Repositionabel mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 50-S/SP33-1106 Technology Open Loop Hall Effect Aperture 15 x 8mm ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 50 Amp Measurement Range +/-625 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B5B-PH type Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$46.00
$54.28 inclGST -
HO 250-S/SP33-1106, O/L Hall Effect Current Sensor, 250 Amp, 15 x 8mm Aperture, Vref = 1.65V, Panel Mount
LEM HO 250-S/SP33-1106, O/L Hall Effect Current Sensor, 250 Amp, 15 x 8mm Aperture, Vref = 1.65V, Panel Mount Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single power supply +3.3 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for panel mounting Aperture: 15 × 8 mm Factory calibrated Repositionabel mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 250-S/SP33-1106 Technology Open Loop Hall Effect Aperture 15 x 8mm ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 250 Amp Measurement Range +/-625 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B5B-PH type Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$43.27
$51.06 inclGST -
DVC 1000-P, C/L Voltage Transducer, 1000V AC/DC, 5VDC Supply, 2.5Vref Instantaneous Output, PCB Mount
LEM DVC 1000-P, C/L Voltage Transducer, 1000V AC/DC, 5VDC Supply, 2.5Vref Output, PCB Mount Features Bandwidth DC to 47kHz 8 Pins 5V Unipolar Supply Closed loop transducer using Hall Effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Single and Three Phase Inverters Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVC 1000-P Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage 5VDC Primary Nominal Voltage +/-1000V AC/DC Measurement Range +/-1500V AC/DC Output 2.5V Vref 1.17V -> 3.83V (0.5 to 4.5V over range) Instantaneous Isolation 4.2 kV Bandwidth DC-47 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Through Hole PCB Unit Weight 22g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$183.83
$216.92 inclGST