LEM CAS 15-NP C/L Hall Effect Current Sensor, Multi Range, 15 Amp, 2.5V ref out, PCB Mount, No aperture X = 0.8%
Specification
LEM Part Number
CAS 15-NP Sample Kit 3 P
Technology
Closed Loop Multi Range Hall Effect
Aperture
None
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
15 Amp
Measurement Range
+/-51 Amp
Output
2.5 Vref
Isolation
4.2 kV
Bandwidth
DC-300 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.8%
Termination Style
PCB
Unit Weight
9g
Factory Packaging
3
Datasheet
Product Datasheet
LEM LA 125-P/SP4 Series Closed Loop AC/DC Hall Effect Sensor
Features
SP4 = Potted
Bandwidth DC to 150kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mounted with Strain Relief
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LA125-P/SP4
Technology
Closed Loop Hall Effect
Aperture
13 x 11mm
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
130 Amp
Measurement Range
+/-200 Amp
Output
62.5 mA
Isolation
3 kV
Bandwidth
DC-150 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 80°C
Accuracy
0.6%
Termination Style
Through Hole PCB
Unit Weight
35g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM CAS 25-NP Series Closed Loop AC/DC Hall Effect Sensor
Features
Closed loop current transducer
Voltage output
4.2kV Isolation
Frequency bandwidth 300kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Compact design for PCB mounting
Advantages
LTS footprint compatible
Very good dv/dt immunity
Extended measuring range for unipolar measurement.
Reduced height
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Standards
EN 50178: 1997
UL 508: 2013
IEC 61010-1(safety)
Application Domain
Industrial
Specification
LEM Part Number
CAS 25-NP
Technology
Closed Loop Multi Range Hall Effect
Aperture
None
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
25 Amp
Measurement Range
+/-85 Amp
Output
2.5 Vref
Isolation
4.2 kV
Bandwidth
DC-300 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.8%
Termination Style
PCB
Unit Weight
9g
Factory Packaging
25
Datasheet
Product Datasheet
LEM CAS 15-NP Series Closed Loop AC/DC Hall Effect Sensor
Features
Closed loop current transducer
Voltage output
4.2kV Isolation
Frequency bandwidth 300kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Compact design for PCB mounting
Advantages
LTS footprint compatible
Very good dv/dt immunity
Extended measuring range for unipolar measurement.
Reduced height
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Standards
EN 50178: 1997
UL 508: 2013
IEC 61010-1(safety)
Application Domain
Industrial
Specification
LEM Part Number
CAS 15-NP
Technology
Closed Loop Multi Range Hall Effect
Aperture
None
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
15 Amp
Measurement Range
+/-51 Amp
Output
2.5 Vref
Isolation
4.2 kV
Bandwidth
DC-300 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.8%
Termination Style
PCB
Unit Weight
9g
Factory Packaging
25
Datasheet
Product Datasheet
LEM CAS 50-NP KIT3P Series Closed Loop AC/DC Hall Effect Sensor
Features
Closed loop current transducer
Voltage output
4.2kV Isolation
Frequency bandwidth 300kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Compact design for PCB mounting
Advantages
LTS footprint compatible
Very good dv/dt immunity
Extended measuring range for unipolar measurement.
Reduced height
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Standards
EN 50178: 1997
UL 508: 2013
IEC 61010-1(safety)
Application Domain
Industrial
Specification
LEM Part Number
CAS 15-NP Sample Kit 3 P
Technology
Closed Loop Multi Range Hall Effect
Aperture
None
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
50 Amp
Measurement Range
+/-150 Amp
Output
2.5 Vref
Isolation
4.2 kV
Bandwidth
DC-300 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.8%
Termination Style
PCB
Unit Weight
9g
Factory Packaging
3
Datasheet
Product Datasheet
LEM LZSR 200-P Series Closed Loop AC/DC Hall Effect Sensor
Features
SP1 = Higher Measuring Range
Bandwidth DC to 200kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mounted
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LZSR 200-P/SP1
Technology
Closed Loop Hall Effect
Aperture
21 x 11.5mm
ROHS
Yes
Supply Voltage
5VDC
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-450 Amp
Output
2.5V
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
45g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LZSR 150-P/SP1 Series Closed Loop AC/DC Hall Effect Sensor
Features
SP1 = Higher Measuring Range
Bandwidth DC to 200kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mounted
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LZSR 150-P/SP1
Technology
Closed Loop Hall Effect
Aperture
21 x 11.5mm
ROHS
Yes
Supply Voltage
5VDC
Load Current (RMS + DC)
150 Amp
Measurement Range
+/-450 Amp
Output
2.5V
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
45g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LZSR 80-P Series Closed Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 200kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mounted
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LZSR 80-P
Technology
Closed Loop Hall Effect
Aperture
21 x 11.5mm
ROHS
Yes
Supply Voltage
5VDC
Load Current (RMS + DC)
80 Amp
Measurement Range
+/-270 Amp
Output
2.5V
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
45g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LZSR 150-P Series Closed Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 200kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mounted
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LZSR 150-P
Technology
Closed Loop Hall Effect
Aperture
21 x 11.5mm
ROHS
Yes
Supply Voltage
5VDC
Load Current (RMS + DC)
150 Amp
Measurement Range
+/-270 Amp
Output
2.5V
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
45g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LZSR 100-P, C/L Hall Effect Current Sensor, 100 Amp, 2.5V Output, 5V Supply, PCB Mount, X = 1%, Low Offset Drift
Features
Bandwidth DC to 200kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mounted
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LZSR 100-P
Technology
Closed Loop Hall Effect
Aperture
21 x 11.5mm
ROHS
Yes
Supply Voltage
5VDC
Load Current (RMS + DC)
100 Amp
Measurement Range
+/-270 Amp
Output
2.5V
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
45g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LZSR 100-TP Series Closed Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 200kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mounted
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LZSR 100-TP
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
5VDC
Load Current (RMS + DC)
100 Amp
Measurement Range
+/-270 Amp
Output
2.5V
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
45g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LZSR 200-TP/SP1 Series Closed Loop AC/DC Hall Effect Sensor
Features
SP1 = Higher Measuring Range
Bandwidth DC to 200kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mounted
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LZSR 200-TP/SP1
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
5VDC
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-450 Amp
Output
2.5V
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
45g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes