LEM DHAB S/160, O/L Automotive AC/DC Current Transducer, Multirange +/-50A +/-350A, 5VDC Supply, 22.5mm Round Aperture
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-30A, and +/-350A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Â
Specification
LEM Part Number
DHAB S/160
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-50 Amp
Load Current Channel 2 (RMS)
+/-350 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 1.1kHz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.45%(20A),0.7%(30A)
CH2 Accuracy @ 25 Deg C
1%(0A),3.5%(175A),5%(350A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
LEM LT 505-T C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, w/ busbar, +/-15..24VDC, X = 0.6%, Can replace LT 505-T/SP3
Features
Bipolar and Insuated current measurement up tp 1200 Amp
Current output
Bandwidth DC to 150kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offest drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 505-T
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
500 Amp
Measurement Range
+/- 1200 Amp
Output
100 mA
Isolation
6 kV
Bandwidth
DC-150 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.6%
Termination Style
Faston 6.3 x 0.8mm
Unit Weight
850g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
LEM DHAB S/145, Automotive Hall Effect Sensor, Dual Measurement Range, CH1: +/-50A CH2: +/-200A, Cable or Panel Mount, 22.5mm round aperture
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-75A, and +/-1000A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/145
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-50 Amp
Load Current Channel 2 (RMS)
+/-200 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 70Hz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
15%(0A),0.7%(25A),1.3%(75A)
CH2 Accuracy @ 25 Deg C
3%(0A),9%(500A),15%(900A),20%(1000A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM LT 4000-T/SP35, C/L Hall Effect Current Sensor, +/-24VDC Supply, Isn = 800mA, 100m Busbar Mount, X = 0.5%, Secondary Connection by AMP CPC 13/9
Features
Bipolar and insulated current measurement up tp 6000 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 4000-T/SP35
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
4000 Amp
Measurement Range
+/- 6000 Amp
Output
800 mA
Isolation
6 kV
Bandwidth
DC-100 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.5%
Termination Style
AMP CPC 13/9
Unit Weight
12.1kg
Factory Pack Quantity
1
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
LEM LT 4000-T/SP11, C/L Hall Effect Current Sensor, +/-24VDC Supply, Isn = 800mA, 100mm Busbar Mount, X = 0.5%, Secondary Connection by LEMOEGJ.1B.305.CYC
Features
Bipolar and insulated current measurement up tp 6000 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 4000-T/SP11
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
4000 Amp
Measurement Range
+/- 6000 Amp
Output
800 mA
Isolation
6 kV
Bandwidth
DC-100 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.5%
Termination Style
LEMOEGJ.1B.305.CYC
Unit Weight
12.1kg
Factory Pack Quantity
1
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
Automotive Open Loop Current Sensor for up to 48VDC Battery, +/-600 Amp and +/-200Amp Dual Outputs, Battery Drive, Vref = 2.5V output
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range, +/-50 Amp and +/-500Amp Dual Outputs
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
HSNBV-D09
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-50 Amp
Load Current Channel 2 (RMS)
+/-500 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Mounting Style
Panel Mount/Cable Mount
Termination Style
Fuse Mounting Style
Unit Weight
25g
Factory Pack Qty
6
Datasheet
Product Datasheet
Automotive Open Loop Current Sensor for up to 48VDC Battery, 0-120 Amp and +/-200Amp Dual Outputs, Battery Drive, Vref = 2.5V output
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range, 0-120 Amp and +/-200Amp Dual Outputs
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
HSNBV-D02
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
120 Amp
Load Current Channel 2 (RMS)
+/-200 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Mounting Style
Panel Mount/Cable Mount
Termination Style
Fuse Mounting Style
Unit Weight
25g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM LT 4000-S/SP24 C/L Hall Effect Current Sensor, Ipn = 3300 Amp, Isn = 660mA, +/-24VDC Supply, Busbar, X = 0.5%, panel mount
Features
Bipolar and insulated current measurement up tp 6000 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 4000-S/SP24
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
3300 Amp
Measurement Range
+/- 6000 Amp
Output
660 mA
Isolation
6 kV
Bandwidth
DC-100 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.5%
Termination Style
M5 threaded studs
Unit Weight
12.1kg
Factory Pack Quantity
1
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOP 800-SB O/L Split Core Hall Effect Current Sensor, 800 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% Open Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 10kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical or Busbar Mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 500 to 2500 A in one package.
Up to 3000 A measurement range
Applications
Power supplies for TELECOM (monitoring and measurement)
Electrical chemistry
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Chopper
Battery supplied applications
Specification
LEM Part Number
HOP 800-SB
Technology
Open Loop Hall Effect
Aperture
104 x 40mm Square
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
800 Amp
Measurement Range
+/-1600 Amp
Overload Rating
Contact Us for Possible Replacement
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-10 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
2%
Termination Style
Molex 5045-04A
Unit Weight
590g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOP 600-SB O/L Split Core Hall Effect Current Sensor, 600 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% AC/DC Hall Effect Sensor
Features
Bandwidth DC to 10kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical or Busbar Mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 200 to 600 A in one package.
Up to 900 A measurement range
Applications
Power supplies for TELECOM (monitoring and measurement)
Electrical chemistry
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Chopper
Battery supplied applications
Specification
LEM Part Number
HOP 600-SB
Technology
Open Loop Hall Effect
Aperture
12.5 x 41mm Square
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
600 Amp
Measurement Range
+/-1200 Amp
Overload Rating
Contact Us for Possible Replacement
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-10 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
2%
Termination Style
Molex 5045-04A
Unit Weight
590g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOP 400-SB O/L Split Core Hall Effect Current Sensor, 400 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X =2% AC/DC Hall Effect Sensor
Features
Bandwidth DC to 8kHz
Open loop transducer using Hall effect
Compact and versatile
Busbar Mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 200 to 600 A in one package.
Up to 900 A measurement range
Applications
Power supplies for TELECOM (monitoring and measurement)
Electrical chemistry
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Chopper
Battery supplied applications
Specification
LEM Part Number
HOP 400-SB
Technology
Open Loop Hall Effect
Aperture
12.5 x 41mm
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
400 Amp
Measurement Range
+/-600 Amp
Overload Rating
Contact Us for Possible Replacement
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-8 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
2%
Termination Style
Molex 5045-04A
Unit Weight
110g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOP 300-SB O/L Split Core Hall Effect Current Sensor, 300 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% AC/DC Hall Effect Sensor
Features
Bandwidth DC to 8kHz
Open loop transducer using Hall effect
Compact and versatile
Busbar Mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 200 to 600 A in one package.
Up to 900 A measurement range
Applications
Power supplies for TELECOM (monitoring and measurement)
Electrical chemistry
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Chopper
Battery supplied applications
Specification
LEM Part Number
HOP 600-SB
Technology
Open Loop Hall Effect
Aperture
12.5 x 41mm
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
300 Amp
Measurement Range
+/-450 Amp
Overload Rating
Contact Us for Possible Replacement
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-8 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
2%
Termination Style
Molex 5045-04A
Unit Weight
110g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition