Current Sensors with Process Outputs

279 products

  • ATO 5 B420 D10/SP4, AC CT, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5%-AC Current Transformer with Process Output-LEM International SA-Fastron Electronics Store

    ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5%

    19 pcs in stock

    LEM ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5% Features 125 Amp AC Current Measurement Signal Conditioned output Split Core 4-20mA Current Output Cable or Din Rail Mounting 20-28VDC Powered Isolated plastic case recognised according to UL94-V0 UL508 Rated Advantages Large aperture for cable up to ? 10mm High isolation between primary and secondary circuits Easy installation Applications Hybrid Inverter Power Metering Power Quality Analysis Distributed Measurement Systems Current Measurement Energy Management Motor Control Condition Monitoring Specification LEM Part Number ATO-5-B420-D10-SP4 Technology AC Current Transformer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 125 Amp Output 4-20mA (Average RMS) Isolation 4.3kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount or Cable Mount Operating Temperature Range -10°C / 55°C Accuracy 1.5% Termination Style 4M Output Cable Unit Weight 140g Factory Pack Qty 6   Datasheet Product Datasheet  

    19 pcs in stock

    $181.50
    $214.17 inclGST

  • FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy

    FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy

    50 pcs in stock

    Fastron FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy (FCS521-SD-420E) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output Features Average RMS 4-20mA output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES521-FD-420E Technology Solid Core Solid Core AC Current Transducer Range 0-10Amp, 0-20Amp, 0-50Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 4-20mA Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant   Datasheet Product Datasheet Installation Guide  

    50 pcs in stock

    $79.00
    $93.22 inclGST

  • LEM International SA Split Core AC Current Transformer with Process Output ATO-5-B420-D10-SP4, AC CT, 20-30VDC loop powered, 5 Amp Average RMS 4-20mA output, X = 1.5% FE-ATO-5-B420-D10-SP4

    TOP 90-S10/SP4, AC Current Transformer, 90 Amp 0-90mA rms output, X = 1%

    139 pcs in stock

    LEM TOP 90-S10/SP4, AC Current Transformer, 90 Amp 0-90mA rms output, X = 1% Features 90 Amp AC Current Measurement Signal Conditioned output Split Core 0-90mA Instantaneous Cable or Din Rail Mounting Self Powered Isolated plastic case recognised according to UL94-V0 UL508 Rated Advantages Large aperture for cable up to ? 10mm High isolation between primary and secondary circuits Easy installation Applications Hybrid Inverter UPS Power Metering Power Quality Analysis Distributed Measurement Systems Current Measurement Energy Management Motor Control Condition Monitoring Specification LEM Part Number TOP 90-S10/SP4 Technology AC Current Transformer Protection Class IP50 Supply Voltage Self Powered Load Current (RMS) 125 Amp Output 0-90mA rms Isolation 4.3kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount or Cable Mount Operating Temperature Range -25°C / 70°C (for 100°C Conductors) Accuracy 1.5% Termination Style 1M Output Cable Unit Weight 150g Factory Pack Qty 6   Datasheet Product Datasheet Alterantive Fastron OEM Alternative

    139 pcs in stock

    $82.60
    $97.47 inclGST

  • FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation

    FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation

    32 pcs in stock

    Fastron FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 24VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 5 B420L Technology AC Current Transformer Protection Class IP50 Supply Voltage 24VDC Loop Powered (10mA) Load Current (RMS) 5 Amp Maximum Measurement Current (RMS) 6 Amp Output 4-20mA (Average RMS) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50 - 400Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 0.5% Aperture 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 140g Factory Pack Qty 6   Datasheet Product Datasheet  

    32 pcs in stock

    $82.00
    $96.76 inclGST

  • FES2151-FD-V10, Solid Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy FES2151-FD-V10, Solid Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy

    FES2151-FD-V10, Solid Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy

    29 pcs in stock

    Fastron FES2151-FD-V10, Solid Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy (FCS2151-SD-V10) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output Features Average RMS 0-10V output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES2151-FD-V10 Technology Solid Core Solid Core AC Current Transducer Range 0-100Amp, 0-150Amp, 0-200Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 200 Amp Output 0-10V Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant   Datasheet Product Datasheet Installation Guide  

    29 pcs in stock

    $69.00
    $81.42 inclGST

  • Last stock! DHR 300 C420, Hall Effect Current Sensor, 300Amp , True RMS 4-20mA output

    DHR 300 C420, Hall Effect Current Sensor, 300Amp , True RMS 4-20mA output

    4 pcs in stock

    LEM DHR 300 C420, Hall Effect Current Sensor, 300Amp , True RMS 4-20mA output Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ?32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 300 C420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 300 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6   Datasheet Product Datasheet

    4 pcs in stock

    $394.00
    $464.92 inclGST

  • F916-SP001 (P030850) (P971211) 25 Amp DC Trackside Measurement Transducer, 0-10VDC Output, 9-36VDC Supply ARTC Approved-DC Current Transducer-Fastron Electronics-Fastron Electronics Store F916-SP001 (P030850) (P971211) 25 Amp DC Trackside Measurement Transducer, 0-10VDC Output, 9-36VDC Supply ARTC Approved-DC Current Transducer-Fastron Electronics-Fastron Electronics Store

    F916-SP001 (P030850) (P971211) 25 Amp DC Trackside Measurement Transducer, 0-10VDC Output, 9-36VDC Supply ARTC Approved

    Out of stock

    F916-SP001 (P030850) (P971211) 25 Amp DC Trackside Measurement Transducer, 0-10VDC Output, 9-36VDC Supply ARTC Approved Features Originally designed for ARTC for lamp monitoring of Rail level crossings for improved safety and status monitoring as mandatory requirement in global Rail networks. In conjunction with direction from Motherwell, Fastron designed a 'bullet proof' Current Transducer to enable reliable status monitoring. We have since designed several AC & DC variations to this design including F920, F922, which are also widely used in rail and several other control and automation industries. Datasheet Product Datasheet

    Out of stock

    $495.00
    $584.10 inclGST

  • AT 20  B10, AC Current Transformer, Self Powered, 20 Amp Average RMS 0-10V output

    AT 20 B10, AC Current Transformer, Self Powered, 20 Amp Average RMS 0-10V output

    Out of stock

    LEM AT 20 B10, AC Current Transformer, Self Powered, 20 Amp Average RMS 0-10V output Features Split Core 0-10V Average RMS Output Cable Mounting Self Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ? 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 20 B10 Technology AC Current Transformer Protection Class IP50 Supply Voltage Self Powered Load Current (RMS) 20 Amp Maximum Measurement Current (RMS) 24 Amp Output 0-10V (Average RMS) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 1.5% Aperture ? 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 90g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    $125.01
    $147.51 inclGST

  • SCT-F24-300-5A, 5 Amp, 300Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F24-300-5A, 5 Amp, 300Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    FAT300D420, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, 500mm Flying Leads

    7 pcs in stock

    Fastron Electronics FAT300D420, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1% Features Quick Release 24mm Split Core System Cale Mount 4-20mA Output 24VDc Loop Powered Rated System Voltage 0.60/2.5kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number FAT300D420 Technology 24mm Split Core AC Current Transformer Ratio 300/4-20mA Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 4-20mA (+20%) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 300g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    7 pcs in stock

    $189.00
    $223.02 inclGST

  • FES2151-FP-V10, Split Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy FES2151-FP-V10, Split Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy

    FES2151-FP-V10, Split Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy

    51 pcs in stock

    Fastron FES2151-FP-V10, Split Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy FCS2151-SP-V10 Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output Features Average RMS 0-10V output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES2151-FD-V10 Technology Solid Core Split Core AC Current Transducer Range 0-100Amp, 0-150Amp, 0-200Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 200 Amp Output 0-10V Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant   Datasheet Product Datasheet Installation Guide    

    51 pcs in stock

    $79.00
    $93.22 inclGST

  • FES521-FD-V10,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 0-10V Output. 1% Accuracy FES521-FD-V10,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 0-10V Output. 1% Accuracy

    FES521-FD-V10,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 0-10V Output. 1% Accuracy

    34 pcs in stock

    Fastron FES521-FD-V10,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 0-10V Output. 1% Accuracy (FCS521-SD-V10) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output Features Average RMS 0-10V output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES521-FD-V10 Technology Solid Core Solid Core AC Current Transducer Range 0-10Amp, 0-20Amp, 0-50Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 0-10V Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant   Datasheet Product Datasheet Installation Guide  

    34 pcs in stock

    $69.00
    $81.42 inclGST

  • DCT-0010-050, AC CT, Self Powered, 50 Amp Average RMS 0-5V output

    DCT-0010-050, AC CT, Self Powered, 50 Amp Average RMS 0-5V output

    Out of stock

    Magnelab DCT-0010-050, AC CT, Self Powered, 50 Amp Average RMS 0-5V output Features Split Core 0-5V Average RMS Output Cable Mounting Self Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀ 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification Magnelab Part Number DCT-0010-050 Technology AC Current Transformer Supply Voltage Self Powered Load Current (RMS) 50 Amp Maximum Measurement Current (RMS) 75 Amp Output 0-5V (Average RMS) 5% Ripple Response Time 300ms Isolation 2.5kV (AC, 50Hz, 1 min) Voltage Rating Cat III 600VAC Bandwidth 50/60Hz Mounting Style Cable Mount Operating Temperature Range -20°C / 50°C Accuracy 2% Aperture ⌀ 10mm Termination Style Screw Approvals CE,UL,ROHS2 Unit Weight 70g Factory Pack Qty 6 Datasheet Product Datasheet

    Out of stock

    $138.00
    $162.84 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account