Current Sensors with Process Outputs

279 products

  • Last stock! MCT-0024-250, 250 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)

    MCT-0024-250, 250 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)

    3 pcs in stock

    Magnelab MCT-0024-250, 250 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 20-30VDC Loop Powered Isolated plastic case recognised according to UL94-V0 UL, CE, ROHS Approved Advantages Large aperture for cable up to ⌀ 24mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification Magnelab Part Number MCT-0024-250 Technology AC Current Transducer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 250 Amp Output 4-20mA (Average RMS) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy +/-2% Ripple on output Termination Style Screw Aperture 24mm Approvals UL, CE, ROHS Unit Weight 200g Factory Pack Qty 6   Datasheet Product Datasheet  

    3 pcs in stock

    $283.50
    $334.53 inclGST

  • Northern Design Electronics Ltd AC Current Transformer with Process Output XD-I420-1, AC Current Transducer, Average RMS, Ipn = Selectable 5,10,15,20,25 Amp, 4-20mA out, 16-36VDC Loop powered FE-XD-I420-1

    XD-I420-1, AC Current Transducer, Average RMS, Ipn = Selectable 5,10,15,20,25 Amp, 4-20mA out, 16-36VDC Loop powered

    15 pcs in stock

    Northern Design XD-I420-1, AC Current Transducer, Average RMS, Ipn = Selectable 5,10,15,20,25 Amp, 4-20mA out, 16-36VDC Loop powered Features Ipn = Selectable 5,10,15,20,25 Amp Average RMS Output 4-20mA Current Output Din Rail Mounting 16-36VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀ 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Earth Leakage Measurement Motor Control Actuators Lamp Failure Specification Northern Design Part Number XD-I420-1 Technology AC Current Transformer Protection Class IP50 Supply Voltage 16-36VDC Loop Powered (10mA) Load Current (RMS) Selectable 5,10,15,20,25 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy Class 1 Termination Style Screw Unit Weight 180g Factory Pack Qty 6   Datasheet Product Brochure Product Manual  

    15 pcs in stock

    $179.00
    $211.22 inclGST

  • DHR 500 C420, Hall Effect Current Sensor, 500Amp , True RMS 4-20mA output

    DHR 500 C420, Hall Effect Current Sensor, 500Amp , True RMS 4-20mA output

    7 pcs in stock

    LEM DHR 500 C420, Hall Effect Current Sensor, 500Amp , True RMS 4-20mA output Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ?32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 500 C420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 500 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6   Datasheet Product Datasheet

    7 pcs in stock

    $394.00
    $464.92 inclGST

  • AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output

    AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output

    10 pcs in stock

    LEM AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 20-30VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ? 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 5 B420L Technology AC Current Transformer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 5 Amp Maximum Measurement Current (RMS) 6 Amp Output 4-20mA (Average RMS) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 1.5% Aperture ? 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet

    10 pcs in stock

    $237.50
    $280.25 inclGST

  • F922-A-07-V1-SP03 DC Current Transducer, 0-3 Amp, 1-5V Output, 9-36VDC Supply

    F922-A-07-V1-SP03 DC Current Transducer, 0-3 Amp, 1-5V Output, 9-36VDC Supply

    F922-A-07-V1-SP03 Din Rail Mount DC Current Transducer - Special Build (SP03) Input: 0-3 Amp Output: 1-5V Analogue Power Supply: 9-36VDC Datasheet Product Datasheet

    $542.00
    $639.56 inclGST

  • FES2151-FP-V5, Split Core AC Current Transducer, Multirange 100A, 150A, 200A, Average RMS 0-5V Output. 1% Accuracy FES521-FP-V10, AC Current Transducer, Multirange 10A,20A, 50A, Average RMS 0-10V Output. 2% Accuracy-AC Current Transformer with Process Output-Fastron Electronics-Fastron Electronics Store

    FES2151-FP-V5, Split Core AC Current Transducer, Multirange 100A, 150A, 200A, Average RMS 0-5V Output. 1% Accuracy

    52 pcs in stock

    Fastron FES2151-FP-V5, Split Core AC Current Transducer, Multirange 100A, 150A, 200A, Average RMS 0-5V Output. 1% Accuracy (FCS2151-FP-V5) Compact and versatile current switches for detection of AC Currents, Multirange 0-100Amp, 0-150Amp, 0-200Amp via jumper, 0-5V True RMS output Features True RMS 0-10V output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES2151-FP-V5 Technology Split Core AC Current Transducer Range Selectable 0-100Amp, 0-150Amp, 0-200Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 0-5V Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant   Datasheet Product Datasheet Installation Guide    

    52 pcs in stock

    $79.00
    $93.22 inclGST

  • FES521-FP-V10, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 0-10V Output. 1% Accuracy FES521-FP-V10, AC Current Transducer, Multirange 10A,20A, 50A, Average RMS 0-10V Output. 2% Accuracy-AC Current Transformer with Process Output-Fastron Electronics-Fastron Electronics Store

    FES521-FP-V10, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 0-10V Output. 1% Accuracy

    67 pcs in stock

    Fastron FES521-FP-V10, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 0-10V Output. 1% Accuracy (FCS521-FP-V10) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output Features True RMS 0-10V output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES521-FP-V10 Technology Split Core AC Current Transducer Range Selectable 0-10Amp, 0-20Amp, 0-50Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 0-10V Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant Datasheet Product Datasheet Installation Guide

    67 pcs in stock

    $79.00
    $93.22 inclGST

  • DCT-0010-010, AC CT, Self Powered, 10 Amp Average RMS 0-5V output

    DCT-0010-010, AC CT, Self Powered, 10 Amp Average RMS 0-5V output

    7 pcs in stock

    Magnelab DCT-0010-005, AC Current Transducer Self Powered, 10 Amp Average RMS 0-5V output Features Split Core 0-5V Average RMS Output Cable Mounting Self Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀ 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification Magnelab Part Number DCT-0010-010 Technology AC Current Transformer Supply Voltage Self Powered Load Current (RMS) 10 Amp Maximum Measurement Current (RMS) 15 Amp Output 0-5V (Average RMS) 5% Ripple Response Time 300ms Isolation 2.5kV (AC, 50Hz, 1 min) Voltage Rating Cat III 600VAC Bandwidth 50/60Hz Mounting Style Cable Mount Operating Temperature Range -20°C / 50°C Accuracy 2% Aperture ⌀ 10mm Termination Style Screw Approvals CE,UL,ROHS2 Unit Weight 70g Factory Pack Qty 6   Datasheet Product Datasheet

    7 pcs in stock

    $109.90
    $129.68 inclGST

  • FES521-FP-420E, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 4-20mA Output. 1% Accuracy FES521-FP-420E, AC Current Transducer, Multirange 10A,20A, 50A, Average RMS 4-20mA Output. 2% Accuracy-AC Current Transformer with Process Output-Fastron Electronics-Fastron Electronics Store

    FES521-FP-420E, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 4-20mA Output. 1% Accuracy

    80 pcs in stock

    Fastron FES521-FP-420E, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 4-20mA Output. 1% Accuracy (FCS521-FP-420E) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output Features True RMS 4-20mA output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES521-FP-420E Technology Split Core AC Current Transducer Range Selectable 0-10Amp, 0-20Amp, 0-50Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 4-20mA Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant Datasheet Product Datasheet Installation Guide

    80 pcs in stock

    $79.00
    $93.22 inclGST

  • FRC-10-B10, AC Current Transducer, 10 Amp average RMS measurement, 0-10VDC output, 2% Accuracy, Panel Mount-Solid Core AC Current Transformer with Process Output-Fastron Electronics-Fastron Electronics Store FRC-10-B10, AC Current Transducer, 10 Amp average RMS measurement, 0-10VDC output, 2% Accuracy, 14mm Aperture, or 3.5 x 15.5mm busbar, Self Powered, Panel Mount

    FRC-10-B10, AC Current Transducer, 10 Amp average RMS measurement, 0-10VDC output, 2% Accuracy, 14mm Aperture, or 3.5 x 15.5mm busbar, Self Powered, Panel Mount

    40 pcs in stock

    FRC-10-B10, AC Current Transducer, 10 Amp average RMS measurement, 0-10VDC output, 2% Accuracy, 14mm Aperture, or 3.5 x 15.5mm busbar, Self Powered, Panel Mount Compact and low cost olid Core AC current sensor, selectable 10 Amp Average RMS 0-10 V output Features Solid Core Average RMS output 0-10V voltage output Self Powered Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀14mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will nto drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number FRC-10-B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage Self Powered Nominal Current (RMS + DC) 10 Amp Maximum Measurement Current (Peak) 12 Amp Output 0-10V Average RMS Aperture ⌀14mm, or 3.5 x 15.5mm busbar Isolation 6kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex Unit Weight 65g Factory Pack Qty 6   Datasheet Product Datasheet

    40 pcs in stock

    $89.00
    $105.02 inclGST

  • AT 150 B10, Split Core AC Current Sensor, 150 Amp, Average RMS 10V output-AC Current Sensor with Process Output-LEM International SA-Fastron Electronics Store

    AT 150 B10, Split Core AC Current Sensor, Self Powered, 150 Amp, Average RMS 10V output

    8 pcs in stock

    LEM AT 150 B10, Split Core AC Current Sensor, Self Powered, 150 Amp, Average RMS 10V output Compact and versatile Split Core AC current sensor, 150 Amp Average RMS 0-10V output Features Split Core Average RMS output 0-10V voltage output Cable Mounting Self Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ? 16mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications Automation Systems Analogue current reading for remote monitoring (e.g. Motor) Data Loggers Self Powered. Will not drain data logger batteries Panel Meters Simple connection displays power consumption Specification LEM Part Number AT 150 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS) 150 Amp Maximum Measurement Current (RMS) 180 Amp Output 0-10V (Average) RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1.5% Aperture ? 16mm Termination Style Screw Terminal Block Approvals CE,UL,ROHS Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet

    8 pcs in stock

    $119.78
    $141.34 inclGST

  • DHR 200 C420, Hall Effect Current Sensor, 200Amp , True RMS 4-20mA output

    DHR 200 C420, Hall Effect Current Sensor, 200Amp , True RMS 4-20mA output

    6 pcs in stock

    LEM DHR 200 C420, Hall Effect Current Sensor, 200Amp , True RMS 4-20mA output Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ?32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 200 C420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 200 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6   Datasheet Product Datasheet

    6 pcs in stock

    $394.00
    $464.92 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account