Current Sensors with Process Outputs
-
ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5%
LEM ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5% Features 125 Amp AC Current Measurement Signal Conditioned output Split Core 4-20mA Current Output Cable or Din Rail Mounting 20-28VDC Powered Isolated plastic case recognised according to UL94-V0 UL508 Rated Advantages Large aperture for cable up to ? 10mm High isolation between primary and secondary circuits Easy installation Applications Hybrid Inverter Power Metering Power Quality Analysis Distributed Measurement Systems Current Measurement Energy Management Motor Control Condition Monitoring Specification LEM Part Number ATO-5-B420-D10-SP4 Technology AC Current Transformer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 125 Amp Output 4-20mA (Average RMS) Isolation 4.3kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount or Cable Mount Operating Temperature Range -10°C / 55°C Accuracy 1.5% Termination Style 4M Output Cable Unit Weight 140g Factory Pack Qty 6 Datasheet Product Datasheet
$181.50
$214.17 inclGST -
FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy
Fastron FES521-FD-420E,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy (FCS521-SD-420E) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output Features Average RMS 4-20mA output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES521-FD-420E Technology Solid Core Solid Core AC Current Transducer Range 0-10Amp, 0-20Amp, 0-50Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 4-20mA Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant Datasheet Product Datasheet Installation Guide
$79.00
$93.22 inclGST -
TOP 90-S10/SP4, AC Current Transformer, 90 Amp 0-90mA rms output, X = 1%
LEM TOP 90-S10/SP4, AC Current Transformer, 90 Amp 0-90mA rms output, X = 1% Features 90 Amp AC Current Measurement Signal Conditioned output Split Core 0-90mA Instantaneous Cable or Din Rail Mounting Self Powered Isolated plastic case recognised according to UL94-V0 UL508 Rated Advantages Large aperture for cable up to ? 10mm High isolation between primary and secondary circuits Easy installation Applications Hybrid Inverter UPS Power Metering Power Quality Analysis Distributed Measurement Systems Current Measurement Energy Management Motor Control Condition Monitoring Specification LEM Part Number TOP 90-S10/SP4 Technology AC Current Transformer Protection Class IP50 Supply Voltage Self Powered Load Current (RMS) 125 Amp Output 0-90mA rms Isolation 4.3kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount or Cable Mount Operating Temperature Range -25°C / 70°C (for 100°C Conductors) Accuracy 1.5% Termination Style 1M Output Cable Unit Weight 150g Factory Pack Qty 6 Datasheet Product Datasheet Alterantive Fastron OEM Alternative
$82.60
$97.47 inclGST -
FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation
Fastron FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 24VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 5 B420L Technology AC Current Transformer Protection Class IP50 Supply Voltage 24VDC Loop Powered (10mA) Load Current (RMS) 5 Amp Maximum Measurement Current (RMS) 6 Amp Output 4-20mA (Average RMS) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50 - 400Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 0.5% Aperture 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 140g Factory Pack Qty 6 Datasheet Product Datasheet
$82.00
$96.76 inclGST -
FES2151-FD-V10, Solid Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy
Fastron FES2151-FD-V10, Solid Core AC Current Transducer, Multirange 0-100A,150A, 200A, Self Powered, Average RMS 0-10V Output. 1% Accuracy (FCS2151-SD-V10) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output Features Average RMS 0-10V output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES2151-FD-V10 Technology Solid Core Solid Core AC Current Transducer Range 0-100Amp, 0-150Amp, 0-200Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 200 Amp Output 0-10V Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant Datasheet Product Datasheet Installation Guide
$69.00
$81.42 inclGST -
FES521-FD-V10,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 0-10V Output. 1% Accuracy
Fastron FES521-FD-V10,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 0-10V Output. 1% Accuracy (FCS521-SD-V10) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output Features Average RMS 0-10V output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES521-FD-V10 Technology Solid Core Solid Core AC Current Transducer Range 0-10Amp, 0-20Amp, 0-50Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 0-10V Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant Datasheet Product Datasheet Installation Guide
$69.00
$81.42 inclGST -
DHR 300 C420, Hall Effect Current Sensor, 300Amp , True RMS 4-20mA output
LEM DHR 300 C420, Hall Effect Current Sensor, 300Amp , True RMS 4-20mA output Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ?32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 300 C420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 300 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
$394.00
$464.92 inclGST -
F916-SP001 (P030850) (P971211) 25 Amp DC Trackside Measurement Transducer, 0-10VDC Output, 9-36VDC Supply ARTC Approved
Free Aus Post Shipping for $300 SpendF916-SP001 (P030850) (P971211) 25 Amp DC Trackside Measurement Transducer, 0-10VDC Output, 9-36VDC Supply ARTC Approved Features Originally designed for ARTC for lamp monitoring of Rail level crossings for improved safety and status monitoring as mandatory requirement in global Rail networks. In conjunction with direction from Motherwell, Fastron designed a 'bullet proof' Current Transducer to enable reliable status monitoring. We have since designed several AC & DC variations to this design including F920, F922, which are also widely used in rail and several other control and automation industries. Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$495.00
$584.10 inclGST -
AT 20 B10, AC Current Transformer, Self Powered, 20 Amp Average RMS 0-10V output
Free Aus Post Shipping for $300 SpendLEM AT 20 B10, AC Current Transformer, Self Powered, 20 Amp Average RMS 0-10V output Features Split Core 0-10V Average RMS Output Cable Mounting Self Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ? 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 20 B10 Technology AC Current Transformer Protection Class IP50 Supply Voltage Self Powered Load Current (RMS) 20 Amp Maximum Measurement Current (RMS) 24 Amp Output 0-10V (Average RMS) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 1.5% Aperture ? 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet
-
F922-A-07-V1-SP03 DC Current Transducer, 0-3 Amp, 1-5V Output, 9-36VDC Supply
F922-A-07-V1-SP03 Din Rail Mount DC Current Transducer - Special Build (SP03) Input: 0-3 Amp Output: 1-5V Analogue Power Supply: 9-36VDC Datasheet Product Datasheet
$542.00
$639.56 inclGST -
FAT300D420, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1%, 500mm Flying Leads
Fastron Electronics FAT300D420, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 4-20mA Average RMS Output, Accuracy = 1% Features Quick Release 24mm Split Core System Cale Mount 4-20mA Output 24VDc Aux Rated System Voltage 0.60/2.5kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FAT300D420 Technology 24mm Split Core AC Current Transformer Ratio 300/4-20mA Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 4-20mA (+20%) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$189.00
$223.02 inclGST -
FES521-FP-V10, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 0-10V Output. 1% Accuracy
Fastron FES521-FP-V10, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 0-10V Output. 1% Accuracy (FCS521-FP-V10) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output Features True RMS 0-10V output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES521-FP-V10 Technology Split Core AC Current Transducer Range Selectable 0-10Amp, 0-20Amp, 0-50Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 0-10V Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant Datasheet Product Datasheet Installation Guide
$79.00
$93.22 inclGST