Hall Effect Current Sensors

543 products

  • LEM International SA AC/DC Current Hall Effect Sensor HO 250-S-0100, O/L Hall Effect Current Sensor, 250 Amp, 15 x 8mm Aperture, Vref = 2.5V, Panel Mount FE-HO 250-S-0100

    HO 250-S/SP33-1106, O/L Hall Effect Current Sensor, 250 Amp, 15 x 8mm Aperture, Vref = 1.65V, Panel Mount

    126 pcs in stock

    LEM HO 250-S/SP33-1106, O/L Hall Effect Current Sensor, 250 Amp, 15 x 8mm Aperture, Vref = 1.65V, Panel Mount Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single power supply +3.3 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for panel mounting Aperture: 15 × 8 mm Factory calibrated Repositionabel mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 250-S/SP33-1106 Technology Open Loop Hall Effect Aperture 15 x 8mm ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 250 Amp Measurement Range +/-625 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B5B-PH type Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    126 pcs in stock

    $43.27
    $51.06 inclGST

  • HY 50-P/SP1, Hall Effect Current Sensor, 50 Amp, 0-5V output, no aperture, 5V Supply, PCB Mount, X = 2%

    HY 50-P/SP1, Hall Effect Current Sensor, 50 Amp, 0-5V output, no aperture, 5V Supply, PCB Mount, X = 2%

    Out of stock

    Free Aus Post Shipping for $300 Spend

    Hall Effect Current Sensor, 50 Amp, 0-5V output, no aperture, 5V Supply, PCB Mount, X = 2%

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $128.80
    $151.98 inclGST

  • LEM International SA AC/DC Current Hall Effect Sensor HT 200-SRID, O/L Hall Effect Current Sensor, 200 Amp, 23mm round FE-HT 200-SRID

    HT 200-SRID, O/L Hall Effect Current Sensor, 200 Amp, 23mm round

    Out of stock

    Free Aus Post Shipping for $300 Spend

    HT 200-SRID, O/L Hall Effect Current Sensor, 200 Amp, 23mm round Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $172.50
    $203.55 inclGST

  • HOYS 560-S-0100, O/L Hall Effect Current Sensor,560 Amp, 5VDC Supply, Panel Mount, 13 x 21.5mm Aperture, X = 1%

    HOYS 560-S-0100, O/L Hall Effect Current Sensor,560 Amp, 5VDC Supply, Panel Mount, 13 x 21.5mm Aperture, X = 1%

    40 pcs in stock

    LEM HOYS 560-S-0100 Series Closed Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Voltage output Single supply +5 V Overcurrent detect 2.93 × IPN (peak value) Galvanic separation between primary and secondary circuit Low power consumption For busbar mounting Aperture: 21.5 × 13 mm Factory calibrated ● Mating JST connector: housing PAP-05V-S contact SPHD-00xT-P0.5. Advantages Low offset drift Over-drivable Vref Creepage / clearance > 10.5 mm Fast response Low profile 2 mm pitch connector for 22 to 28 AWG wire. Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 ● IEC 62109-1: 2010 ● UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HOYS 560-S-0100 Technology Open Loop Hall Effect Aperture 21.5 x 13mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 560 Amp Measurement Range +/-1400 Amp Output 2.5 Vref Isolation 5.4 kV Bandwidth DC-180 kHz Mounting Style Busbar Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B05B-PASK or equivalent Unit Weight 101g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    40 pcs in stock

    $60.10
    $70.92 inclGST

  • HOYL 200-S-0100, Hall Effect Current Sensor, 200 Amp, 5VDC Supply, PCB Mount, 13 x 40mm Aperture, X = 1%

    HOYL 200-S-0100, Hall Effect Current Sensor, 200 Amp, 5VDC Supply, PCB Mount, 13 x 40mm Aperture, X = 1%

    1120 pcs in stock

    LEM HOYL 200-S-0100 Series Closed Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Voltage output Single supply +5 V Overcurrent detect 2.93 × IPN (peak value) Galvanic separation between primary and secondary circuit Low power consumption For busbar mounting Aperture: 40 × 13 mm Factory calibrated ? Mating JST connector: housing PAP-05V-S contact SPHD-00xT-P0.5. Advantages Low offset drift Over-drivable Vref Creepage / clearance > 10.5 mm Fast response Low profile 2 mm pitch connector for 22 to 28 AWG wire. Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HOYL 200-S-0100 Technology Open Loop Hall Effect Aperture 40 x 13mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 200 Amp Measurement Range +/-500 Amp Output 2.5 Vref Isolation 8 kV Bandwidth DC-140 kHz Mounting Style Busbar Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B05B-PASK or equivalent Unit Weight 232g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    1120 pcs in stock

    $140.72
    $166.05 inclGST

  • LAH 100-P, C/L Hall Effect Current Sensor, 100 Amp, +/-12..15V, PCB Mount, X = 0.25%, 5kV Isolation

    LAH 100-P, C/L Hall Effect Current Sensor, 100 Amp, +/-12..15V, PCB Mount, X = 0.25%, 5kV Isolation

    45 pcs in stock

    LEM LAH 100-P, C/L Hall Effect Current Sensor, 100 Amp, +/-12..15V, PCB Mount, X = 0.25%, 5kV Isolation Features Bandwidth DC to 200kHz Closed loop transducer using Hall effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LAH100-P Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 100 Amp Measurement Range +/-160Amp Output 50 mA Isolation 5 kV Bandwidth DC-200 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 85°C Accuracy 0.25% Termination Style Through Hole PCB Unit Weight 20g Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition    

    45 pcs in stock

    $38.18
    $45.05 inclGST

  • HTR 200-SB O/L Hall Effect Current Sensor, 200 Amp, +/-4V Output, Split Core 21mm Aperture, X = 2%

    HTR 200-SB O/L Hall Effect Current Sensor, 200 Amp, +/-4V Output, Split Core 21mm Aperture, X = 2%

    8 pcs in stock

    LEM HTR 200-SB Open Loop Hall Effect Current Sensor, 200 Amp, +/-4V Output, Split Core 21mm Aperture, X = 2% Features Bandwidth DC to 10kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 500 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTR 200-SB Technology Split Core Open Loop Hall Effect Aperture ø21mm ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/-400 Amp Output +/-4 V Isolation 4 kV Bandwidth DC-10 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 70°C Accuracy 2% Termination Style Molex 5046-04A/AG Unit Weight 80g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    8 pcs in stock

    $278.50
    $328.63 inclGST

  • HTFS 600-P, O/L Hall Effect Current Sensor, 600 Amp, 5VDC Supply, PCB Mount, X = 1%

    HTFS 600-P, O/L Hall Effect Current Sensor, 600 Amp, 5VDC Supply, PCB Mount, X = 1%

    165 pcs in stock

    LEM HTFS 600-P, Open Loop Hall Effect Current Sensor, 600 Amp, 5VDC Supply, PCB Mount, X = 1% Features Bandwidth DC to 240kHz Open loop transducer using Hall effect Compact and versatile Uinique PCB Mounting Insulated plastic case recognized according to UL 94-V0 Advantages Fixed offset Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTFS 600-P Technology Open Loop Hall Effect Aperture ø 22mm ROHS Yes Supply Voltage 5 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/-900 Amp Output 1.65Vref Isolation 2.5 kV Bandwidth DC-240 kHz Mounting Style PCB Mount (fixation with 4 pins 1mm) Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Unit Weight 60g Factory Pack Quantity 10 Datasheet Product Datasheet

    165 pcs in stock

    $46.60
    $54.99 inclGST

  • HO 150-NP-0100, O/L Multi Range Hall Effect Current Sensor, 150 Amp, No Aperture, PCB Mount

    HO 150-NP-0100, O/L Multi Range Hall Effect Current Sensor, 150 Amp, No Aperture, PCB Mount

    200 pcs in stock

    LEM 150-NP-0100 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Muti rnage through PCB routing Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for PCB mounting Factory calibrated Repositionable mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 150-NP-0100 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 150 Amp Measurement Range +/-375 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-350 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1.5% Termination Style PCB Through Hole Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    200 pcs in stock

    $33.00
    $38.94 inclGST

  • HO 120-NP-0100, O/L Multi Range Hall Effect Current Sensor, 120 Amp, No Aperture, PCB Mount

    HO 120-NP-0100, O/L Multi Range Hall Effect Current Sensor, 120 Amp, No Aperture, PCB Mount

    150 pcs in stock

    LEM HO 120-NP-0100 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for PCB mounting Factory calibrated Repositionable mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 120-NP-0100 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 120 Amp Measurement Range +/-300 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-350 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1.5% Termination Style PCB Through Hole Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    150 pcs in stock

    $44.20
    $52.16 inclGST

  • HO 100-S-0100, O/L Hall Effect Current Sensor, 100 Amp, 18.8 x 10.5mm Aperture, Panel Mount

    HO 100-S-0100, O/L Hall Effect Current Sensor, 100 Amp, 18.8 x 10.5mm Aperture, Panel Mount

    190 pcs in stock

    LEM HO 100-S-0100 Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single power supply +5 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Factory calibrated Compact design for panel mounting Aperture: 15 × 8 mm Factory calibrated Repositionabel mounting foot Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 100-S-0100 Technology Open Loop Hall Effect Aperture 15 x 8mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 100 Amp Measurement Range +/-250 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B5B-PH type Unit Weight 32g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    190 pcs in stock

    $44.20
    $52.16 inclGST

  • HMS 10-P, O/L Hall Effect Current Sensor, 10 Amp, 5VDC Supply, PCB Mount, MOQ = 150pcs

    HMS 10-P, O/L Hall Effect Current Sensor, 10 Amp, 5VDC Supply, PCB Mount, MOQ = 150pcs

    8 pcs in stock

    LEM HMS 10-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Single supply +5 V Galvanic separation between primary and secondary circuit Low power consumption SMT PCB mounting Factory calibrated Advantages Small Size and space saving Singe paclage for wide current ranges 5 -> 20 Amp High Immunity to external interference Low offset drift Over-drivable VREF Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Standards IEC 61010-1 EN50178 Application Domain Industrial Specification LEM Part Number HMS 10-P Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 30 Amp Measurement Range +/-15 Amp Output 2W RS422 Manchester Isolation 4.3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style PCB Unit Weight 6g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    8 pcs in stock

    $24.36
    $28.74 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account