Hall Effect Current Sensors

543 products

  • HC5FW 600-S, Automotive Open Loop Current Sensor for Low Voltage, +/-600 Amp, 5VDC Supply

    HC5FW 600-S, Automotive Open Loop Current Sensor for Low Voltage, +/-600 Amp, 5VDC Supply

    Out of stock

    HC5FW 600-S, Automotive Open Loop Current Sensor for Low Voltage, +/-600 Amp, 5VDC Supply Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range, +/-100 to +/-900 Models Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles   Specification LEM Part Number HC5FW 600-S Technology Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current (Ipn) (RMS) +/-600 Amp Output 0.5(-Ipn) to 4.5V(+Ipn) Bandwidth DC - 40kHz Isolation 2.5kV (AC, 50Hz, 1 min) Special Feature SP1 = Cover without Sleeve (Reduced Insulation) Mounting Style Busbar Mount Termination Style 3 Pin Unit Weight 25g Factory Pack Qty 6   Datasheet Product Datasheet Automotive 2022 Web Brochure

    Out of stock

    $37.00
    $43.66 inclGST

  • HC5FW 200-S, Automotive Open Loop Current Sensor for Low Voltage, +/-200 Amp, 5VDC Supply

    HC5FW 200-S, Automotive Open Loop Current Sensor for Low Voltage, +/-200 Amp, 5VDC Supply

    Out of stock

    HC5FW 200-S, Automotive Open Loop Current Sensor for Low Voltage, +/-200 Amp, 5VDC Supply Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range, +/-200 to +/-900 Models Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number HC5FW 200-S Technology Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current (Ipn) (RMS) +/-200 Amp Output 0.5(-Ipn) to 4.5V(+Ipn) Bandwidth DC - 40kHz Isolation 2.5kV (AC, 50Hz, 1 min) Special Feature SP1 = Cover without Sleeve (Reduced Insulation) Mounting Style Busbar Mount Termination Style 3 Pin Unit Weight 25g Factory Pack Qty 6 Datasheet Product Datasheet Automotive 2022 Web Brochure

    Out of stock

    $37.00
    $43.66 inclGST

  • HC5FW 100-S, Automotive Open Loop Current Sensor for Low Voltage, +/-100 Amp, 5VDC Supply

    HC5FW 100-S, Automotive Open Loop Current Sensor for Low Voltage, +/-100 Amp, 5VDC Supply

    Out of stock

    HC5FW 100-S, Automotive Open Loop Current Sensor for Low Voltage, +/-100 Amp, 5VDC Supply Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range, +/-100 to +/-900 Models Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles   Specification LEM Part Number HC5FW 100-S Technology Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current (Ipn) (RMS) +/-100 Amp Output 0.5(-Ipn) to 4.5V(+Ipn) Bandwidth DC - 40kHz Isolation 2.5kV (AC, 50Hz, 1 min) Special Feature SP1 = Cover without Sleeve (Reduced Insulation) Mounting Style Busbar Mount Termination Style 3 Pin Unit Weight 25g Factory Pack Qty 6   Datasheet Product Datasheet Automotive 2022 Web Brochure

    Out of stock

    $37.00
    $43.66 inclGST

  • HC5FW 900-S, Automotive Open Loop Current Sensor for Low Voltage, +/-900 Amp, 5VDC Supply

    HC5FW 900-S, Automotive Open Loop Current Sensor for Low Voltage, +/-900 Amp, 5VDC Supply

    Out of stock

    HC5FW 900-S, Automotive Open Loop Current Sensor for Low Voltage, +/-900 Amp, 5VDC Supply Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range, +/-100 to +/-900 Models Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles   Specification LEM Part Number HC5FW 900-S Technology Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current (Ipn) (RMS) +/-900 Amp Output 0.5(-Ipn) to 4.5V(+Ipn) Bandwidth DC - 40kHz Isolation 2.5kV (AC, 50Hz, 1 min) Special Feature SP1 = Cover without Sleeve (Reduced Insulation) Mounting Style Busbar Mount Termination Style 3 Pin Unit Weight 25g Factory Pack Qty 6   Datasheet Product Datasheet Automotive 2022 Web Brochure

    Out of stock

    $37.00
    $43.66 inclGST

  • HC5FW 700-S, Automotive Open Loop Current Sensor for Low Voltage, +/-700 Amp, 5VDC Supply

    HC5FW 700-S, Automotive Open Loop Current Sensor for Low Voltage, +/-700 Amp, 5VDC Supply

    Out of stock

    HC5FW 700-S, Automotive Open Loop Current Sensor for Low Voltage, +/-700 Amp, 5VDC Supply Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range, +/-100 to +/-900 Models Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles   Specification LEM Part Number HC5FW 700-S Technology Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current (Ipn) (RMS) +/-700 Amp Output 0.5(-Ipn) to 4.5V(+Ipn) Bandwidth DC - 40kHz Isolation 2.5kV (AC, 50Hz, 1 min) Special Feature SP1 = Cover without Sleeve (Reduced Insulation) Mounting Style Busbar Mount Termination Style 3 Pin Unit Weight 25g Factory Pack Qty 6   Datasheet Product Datasheet Automotive 2022 Web Brochure

    Out of stock

    $37.00
    $43.66 inclGST

  • HC5FW 400-S, Automotive Open Loop Current Sensor for Low Voltage, +/-400 Amp, 5VDC Supply

    HC5FW 400-S, Automotive Open Loop Current Sensor for Low Voltage, +/-400 Amp, 5VDC Supply

    Out of stock

    HC5FW 400-S, Automotive Open Loop Current Sensor for Low Voltage, +/-400 Amp, 5VDC Supply Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range, +/-100 to +/-900 Models Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number HC5FW 400-S Technology Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current (Ipn) (RMS) +/-400 Amp Output 0.5(-Ipn) to 4.5V(+Ipn) Bandwidth DC - 40kHz Isolation 2.5kV (AC, 50Hz, 1 min) Special Feature SP1 = Cover without Sleeve (Reduced Insulation) Mounting Style Busbar Mount Termination Style 3 Pin Unit Weight 25g Factory Pack Qty 6 Datasheet Product Datasheet Automotive 2022 Web Brochure

    Out of stock

    $37.00
    $43.66 inclGST

  • HC5FW 300-S, Automotive Open Loop Current Sensor for Low Voltage, +/-300 Amp, 5VDC Supply

    HC5FW 300-S, Automotive Open Loop Current Sensor for Low Voltage, +/-300 Amp, 5VDC Supply

    Out of stock

    HC5FW 300-S, Automotive Open Loop Current Sensor for Low Voltage, +/-300 Amp, 5VDC Supply Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range, +/-100 to +/-900 Models Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number HC5FW 300-S Technology Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current (Ipn) (RMS) +/-300 Amp Output 0.5(-Ipn) to 4.5V(+Ipn) Bandwidth DC - 40kHz Isolation 2.5kV (AC, 50Hz, 1 min) Special Feature SP1 = Cover without Sleeve (Reduced Insulation) Mounting Style Busbar Mount Termination Style 3 Pin Unit Weight 25g Factory Pack Qty 6 Datasheet Product Datasheet Automotive 2022 Web Brochure

    Out of stock

    $37.00
    $43.66 inclGST

  • DHAB S/160, O/L Automotive AC/DC Current Transducer, Multirange +/-50A +/-350A, 5VDC Supply, 22.5mm Round Aperture

    DHAB S/160, O/L Automotive AC/DC Current Transducer, Multirange +/-50A +/-350A, 5VDC Supply, 22.5mm Round Aperture

    Out of stock

    LEM DHAB S/160, O/L Automotive AC/DC Current Transducer, Multirange +/-50A +/-350A, 5VDC Supply, 22.5mm Round Aperture Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range up to +/-30A, and +/-350A for Channel 2 Maximum RMS primary admissable current: defined by busbar to have T° < +150°C Operating Temperature Range: -40°C < T° < +125°C Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles   Specification LEM Part Number DHAB S/160 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current Channel 1 (RMS) +/-50 Amp Load Current Channel 2 (RMS) +/-350 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth(-3dB) DC - 1.1kHz Mounting Style Panel Mount/Cable Mount Aperture ⌀22.5mm Operating Temperature Range -40°C - 70°C CH1 Accuracy @ 25 Deg C 0.15%(0A),0.45%(20A),0.7%(30A) CH2 Accuracy @ 25 Deg C 1%(0A),3.5%(175A),5%(350A) Termination Style TYCO 1-1456426-5 Unit Weight 100g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    $75.00
    $88.50 inclGST

  • FHS 40-P/SP600, O/L Hall Effect Sensor, 40 Amp, SMD-AC/DC Current Hall Effect Sensor-LEM International SA-Fastron Electronics Store

    FHS AH 600, O/L Hall Effect Sensor, 40 Amp, SMD

    3000 pcs in stock

    FHS AH 600, O/L Hall Effect Sensor, 40 Amp, SMD, O/L Hall Effect Current Sensor with evaluation PCB, 40 Amp Features Hall effect measuring principle Galvanic separation between primary and secondary circuit Insulated test voltage 3000 V RMS Low power consumption Extremely low profile Single power supply +5 V Double overcurrent detection Fixed offset & sensitivity Response time 5 µs. Advantages Small size and space saving High immunity to external interference High insulation capability Industrial. Low electrical resistance (0.75 mΩ) No magnetic hysteresis Robust against external fields and cross-talk. Applications Appliances Small drives HVAC Solar E-Bikes Standards   IEC 62109-1: 2010 IEC 60950-1: 2005 IEC 61800-5-1: 2007 UL 1577: 2014.   Application Domains Industrial Specification LEM Part Number FHS AH 600 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 5VDC Load Current (RMS + DC) 40 Amp Output 2.5Vref Isolation High/Low configuration Bandwidth DC-105kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 125°C Accuracy N/A Termination Style N/A Unit Weight 10g Factory Pack Qty 2500   Datasheet Product Datasheet

    3000 pcs in stock

    $5.50
    $6.49 inclGST

  • LT 505-T/SP22, C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, w/ busbar, +/-15..24VDC, X = 0.6%, SP22 = -40 to 85 Deg, M4 stud Secondary Connections

    LT 505-T/SP22, C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, w/ busbar, +/-15..24VDC, X = 0.6%, SP22 = -40 to 85 Deg, M4 stud Secondary Connections

    Out of stock

    LEM LT 505-T C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, w/ busbar, +/-15..24VDC, X = 0.6%, Can replace LT 505-T/SP3 Features Bipolar and Insuated current measurement up tp 1200 Amp Current output Bandwidth DC to 150kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offest drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 505-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 500 Amp Measurement Range +/- 1200 Amp Output 100 mA Isolation 6 kV Bandwidth DC-150 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.6% Termination Style Faston 6.3 x 0.8mm Unit Weight 850g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $654.20
    $771.96 inclGST

  • PCM 10-PR/SP1, Pointsenz Railway Bipolar DC Current Sensor, 10 Amp, Bipolar 4-20mA Output, With 0.25M cable

    PCM 10-PR/SP1, Pointsenz Railway Bipolar DC Current Sensor, 10 Amp, Bipolar 4-20mA Output, With 0.25M cable

    Out of stock

    LEM PCM 10-PR/SP1, Pointsenz Railway Bipolar DC Current Sensor, 10 Amp, With 0.25M cable, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected 2M flying leads Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 10-PR/SP1 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 10 Amp Measuring Range +/- 30 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 2% Termination Style Via a 4 core screened Unitronic Etherline H-Flex CAT 5, Lapp number 2170283 length of 0.25 m. Terminated by a male, miniature circular 4 pin connector with a shielding ring series 423. Binder number 99-5109-15-04 Unit Weight 120g Factory Pack Qty 4   Datasheet Product Datasheet Application Notes FAQ

    Out of stock

    $757.55
    $893.91 inclGST

  • LF 2010-S, C/L Hall Effect Sensor, 2000 Amp, +/-400mA Output, 60.5mm Aperture, +/-15..24V Supply, Panel Mount

    LF 2010-S, C/L Hall Effect Sensor, 2000 Amp, +/-400mA Output, 60.5mm Aperture, +/-15..24V Supply, Panel Mount

    6 pcs in stock

    LEM LF 2010-S, C/L Hall Effect Sensor, 2000 Amp, +/-400mA Output, 60.5mm Aperture, +/-15..24V Supply, Panel Mount Features Bipolar and insulated current measurement up tp 2700 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 2010-S Technology Closed Loop Hall Effect Aperture ø60.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/- 3000 Amp Output 400 mA Isolation 6 kV Bandwidth DC-150 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.2% Termination Style Molex 6410 Unit Weight 503g Factory Pack Quantity 9   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    6 pcs in stock

    $437.78
    $516.58 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account