Hall Effect Current Sensors

543 products

  • HLSR 16-PW-080, O/L Hall Effect Current Sensor, 16 Amp, 0-5V Out, PCB Mount

    HLSR 16-PW-080, O/L Hall Effect Current Sensor, 16 Amp, 0-5V Out, PCB Mount

    Out of stock

    LEM HLSR 16-PW-080 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Bitstream output from 2nd order Sigma-Delta modulator, (PDM) Pulse Density Modulation Single supply +5 V Galvanic separation between primary and secondary circuit Low power consumption Compact design for through-hole PCB mounting Factory calibrated High bandwidth, very low loss magnetic core Dedicated parameter settings available on request Advantages Extremely low profile: h = 12mm Low foot-print Low offset drift Over-drivable VREF Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box MPPT Standards IEC 61800-3: 2017 IEC 61800-5-1: 2007 IEC 61800-2: 2015 IEC 62109-1: 2010 UL 508: 2013 IEC 61326-1: 2012 Application Domain Industrial Specification LEM Part Number HLSR 16-PW-080 Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 16 Amp Measurement Range +/-40 Amp Output 2W CMOS CLK In Isolation 4.3 kV Bandwidth DC-400 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Unit Weight 5g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $36.00
    $42.48 inclGST

  • HLSR 16-PW-030, O/L Hall Effect Current Sensor, 16 Amp, 0-5V Out, PCB Mount

    HLSR 16-PW-030, O/L Hall Effect Current Sensor, 16 Amp, 0-5V Out, PCB Mount

    Out of stock

    LEM HLSR 16-PW-030 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Bitstream output from 2nd order Sigma-Delta modulator, (PDM) Pulse Density Modulation Single supply +5 V Galvanic separation between primary and secondary circuit Low power consumption Compact design for through-hole PCB mounting Factory calibrated High bandwidth, very low loss magnetic core Dedicated parameter settings available on request Advantages Extremely low profile: h = 12mm Low foot-print Low offset drift Over-drivable VREF Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box MPPT Standards IEC 61800-3: 2017 IEC 61800-5-1: 2007 IEC 61800-2: 2015 IEC 62109-1: 2010 UL 508: 2013 IEC 61326-1: 2012 Application Domain Industrial Specification LEM Part Number HLSR 16-PW-030 Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 16 Amp Measurement Range +/-40 Amp Output 2W LVDS Manchester Isolation 4.3 kV Bandwidth DC-400 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Unit Weight 5g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $36.00
    $42.48 inclGST

  • HLSR 16-PW-010, O/L Hall Effect Current Sensor, 16 Amp, 0-5V Out, PCB Mount

    HLSR 16-PW-010, O/L Hall Effect Current Sensor, 16 Amp, 0-5V Out, PCB Mount

    Out of stock

    LEM HLSR 16-PW-010 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Bitstream output from 2nd order Sigma-Delta modulator, (PDM) Pulse Density Modulation Single supply +5 V Galvanic separation between primary and secondary circuit Low power consumption Compact design for through-hole PCB mounting Factory calibrated High bandwidth, very low loss magnetic core Dedicated parameter settings available on request Advantages Extremely low profile: h = 12mm Low foot-print Low offset drift Over-drivable VREF Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box MPPT Standards IEC 61800-3: 2017 IEC 61800-5-1: 2007 IEC 61800-2: 2015 IEC 62109-1: 2010 UL 508: 2013 IEC 61326-1: 2012 Application Domain Industrial Specification LEM Part Number HLSR 16-PW-010 Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 16 Amp Measurement Range +/-40 Amp Output 2W RS422 Manchester Isolation 4.3 kV Bandwidth DC-400 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Unit Weight 5g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.60
    $32.57 inclGST

  • HLSR 16-PW-000, O/L Hall Effect Current Sensor, 16 Amp, 0-5V Out, PCB Mount

    HLSR 16-PW-000, O/L Hall Effect Current Sensor, 16 Amp, 0-5V Out, PCB Mount

    Out of stock

    LEM HLSR 16-PW-000 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Bitstream output from 2nd order Sigma-Delta modulator, (PDM) Pulse Density Modulation Single supply +5 V Galvanic separation between primary and secondary circuit Low power consumption Compact design for through-hole PCB mounting Factory calibrated High bandwidth, very low loss magnetic core Dedicated parameter settings available on request Advantages Extremely low profile: h = 12mm Low foot-print Low offset drift Over-drivable VREF Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box MPPT Standards IEC 61800-3: 2017 IEC 61800-5-1: 2007 IEC 61800-2: 2015 IEC 62109-1: 2010 UL 508: 2013 IEC 61326-1: 2012 Application Domain Industrial Specification LEM Part Number HLSR 16-PW-000 Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 16 Amp Measurement Range +/-40 Amp Output 2W CMOS CLK Out Isolation 4.3 kV Bandwidth DC-400 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Unit Weight 5g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.60
    $32.57 inclGST

  • HLSR 10-P, O/L Hall Effect Current Sensor with evaluation PCB, 10 Amp

    HLSR 10-P, O/L Hall Effect Current Sensor with evaluation PCB, 10 Amp

    Out of stock

    LEM HLSR 10-P Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output 4.3kV Isolation Frequency bandwidth 400kHz Single supply + 5 V Galvanic isolation between primary and secondary Low power consumption Compact design for THT PCB mounting Factory calibrated. Advantages Extremely low profile: h = 12mm Low foot-print Low offset drift Over-drivable VREF Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box MPPT Standards EN 50178: 1997 UL 508: 2004 - UR marking pending IEC 61326-1: 2012 IEC 61010-1: 2010 (safety) Application Domain Industrial Specification LEM Part Number HLSR 10-P Technology Open Loop Multi Range Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 10 Amp Measurement Range +/-25 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-400 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Unit Weight 5g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $24.50
    $28.91 inclGST

  • HAX 600-S O/L Current Transducer, 600 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    HAX 600-S O/L Current Transducer, 600 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    Out of stock

    LEM HAX 600-S Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 25kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 2500 A in one package. Up to 5500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAX 600-S Technology Open Loop Hall Effect Aperture 64 x 21mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/-1800 Amp Overload Rating +/-30000 At Output +/-4 V Isolation 4.4 kV Bandwidth DC-25 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 450g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $174.00
    $205.32 inclGST

  • HAX 500-S O/L Current Transducer, 500 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    HAX 500-S O/L Current Transducer, 500 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    10 pcs in stock

    LEM HAX 500-S O/L Current Transducer, 500 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output, Hall Effect  Features Bandwidth DC to 25kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 2500 A in one package. Up to 5500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAX 500-S Technology Open Loop Hall Effect Aperture 64 x 21mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 500 Amp Measurement Range +/-1500 Amp Overload Rating +/-30000 At Output +/-4 V Isolation 4.4 kV Bandwidth DC-25 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 450g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    10 pcs in stock

    $163.20
    $192.58 inclGST

  • HAX 2000-S O/L Current Transducer, 2000 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    HAX 2000-S O/L Current Transducer, 2000 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    12 pcs in stock

    LEM HAX Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 25kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 2500 A in one package. Up to 5500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAX 2000-S Technology Open Loop Hall Effect Aperture 64 x 21mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/-6000 Amp Overload Rating +/-30000 At Output +/-4 V Isolation 4.4 kV Bandwidth DC-25 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 450g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    12 pcs in stock

    $255.00
    $300.90 inclGST

  • HAX 1500-S O/L Current Transducer, 1500 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    HAX 1500-S O/L Current Transducer, 1500 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    Out of stock

    LEM HAX 1500-S O/L Current Transducer, 1500 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output Features Bandwidth DC to 25kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 2500 A in one package. Up to 5500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAX 1500-S Technology Open Loop Hall Effect Aperture 64 x 21mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 1500 Amp Measurement Range +/-4500 Amp Overload Rating +/-30000 At Output +/-4 V Isolation 4.4 kV Bandwidth DC-25 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 450g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $265.00
    $312.70 inclGST

  • HAX 1000-S O/L Current Transducer, 1000 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    HAX 1000-S O/L Current Transducer, 1000 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    7 pcs in stock

    LEM HAX Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 25kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 2500 A in one package. Up to 5500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAX 1000-S Technology Open Loop Hall Effect Aperture 64 x 21mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-3000 Amp Overload Rating +/-30000 At Output +/-4 V Isolation 4.4 kV Bandwidth DC-25 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 450g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    7 pcs in stock

    $217.00
    $256.06 inclGST

  • HAT 800-S O/L Hall Effect Current Transducer, 800 Amp, +/-15V Supply, 40.5 x 30.5 Square Aperture, +/-4V Output

    HAT 800-S O/L Hall Effect Current Transducer, 800 Amp, +/-15V Supply, 40.5 x 30.5 Square Aperture, +/-4V Output

    7 pcs in stock

    LEM HAT 800-S O/L Hall Effect Current Transducer, 800 Amp, +/-15V Supply, 40.5 x 30.5 Square Aperture, +/-4V Output Features Bandwidth DC to 5kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 1500 A in one package. Up to 2500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAT 800-S Technology Open Loop Hall Effect Aperture 40.5 x 30.5mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 800 Amp Measurement Range +/-2400 Amp Output +/-4 V Isolation 4.9 kV Bandwidth DC-25 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 300g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    7 pcs in stock

    $128.00
    $151.04 inclGST

  • HAT 1200-S O/L Hall Effect Current Transducer, 1200 Amp, +/-15V Supply, 40.5 x 30.5 Square Aperture, +/-4V Output

    HAT 1200-S O/L Hall Effect Current Transducer, 1200 Amp, +/-15V Supply, 40.5 x 30.5 Square Aperture, +/-4V Output

    100 pcs in stock

    LEM HAT 1200-S O/L Hall Effect Current Transducer, 1200 Amp, +/-15V Supply, 40.5 x 30.5 Square Aperture, +/-4V Output Features Bandwidth DC to 5kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 1500 A in one package. Up to 2500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAT 1200-S Technology Open Loop Hall Effect Aperture 40.5 x 30.5mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 1200 Amp Measurement Range +/-2500 Amp Output +/-4 V Isolation 4.9 kV Bandwidth DC-25 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 300g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    100 pcs in stock

    $98.00
    $115.64 inclGST

Login

Forgot your password?

Don't have an account yet?