Hall Effect Current Sensors

543 products

  • Last stock! CASR 50-NP KIT3P, C/L Hall Effect Sensor, 50 Amp, 2.5V ref out, PCB Mount

    CASR 50-NP KIT3P, C/L Hall Effect Sensor, 50 Amp, 2.5V ref out, PCB Mount

    1 pcs in stock

    LEM CASR 50-NP KIT3P Series Closed Loop AC/DC Hall Effect Sensor Features Closed loop current transducer Voltage output 4.3kV Isolation Frequency bandwidth 300kHz Single supply + 5 V Galvanic isolation between primary and secondary Low power consumption Compact design for PCB mounting Advantages LTSR footprint compatible Very good dv/dt immunity Very low temperature coefficient of offset Reference pin with two modes REF IN and REF OUT Extended measuring range for unipolar measurement. High creepage / clearance distances Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Solar Inverter Standards EN 50178: 1997 UL 508: 2013 IEC 61010-1(safety) Application Domain Industrial Specification LEM Part Number CASR 50-NP Sample Kit 3 P Technology Closed Loop Multi Range Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 50 Amp Measurement Range +/-150 Amp Output 2.5 Vref Isolation 4.1 kV Bandwidth DC-300 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 85°C Accuracy 0.8% Termination Style PCB Unit Weight 9g Factory Packaging 3 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Alternatives Contact Us for Possible Replacement

    1 pcs in stock

    $118.10
    $139.36 inclGST

  • Last stock! CAS 50-NP KIT3P, C/L Hall Effect Sensor, 50 Amp, 2.5V ref out, PCB Mount

    CAS 50-NP KIT3P, C/L Hall Effect Sensor, 50 Amp, 2.5V ref out, PCB Mount

    1 pcs in stock

    LEM CAS 50-NP KIT3P Series Closed Loop AC/DC Hall Effect Sensor Features Closed loop current transducer Voltage output 4.2kV Isolation Frequency bandwidth 300kHz Single supply + 5 V Galvanic isolation between primary and secondary Compact design for PCB mounting Advantages LTS footprint compatible Very good dv/dt immunity Extended measuring range for unipolar measurement. Reduced height Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Standards EN 50178: 1997 UL 508: 2013 IEC 61010-1(safety) Application Domain Industrial Specification LEM Part Number CAS 15-NP Sample Kit 3 P Technology Closed Loop Multi Range Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 50 Amp Measurement Range +/-150 Amp Output 2.5 Vref Isolation 4.2 kV Bandwidth DC-300 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 85°C Accuracy 0.8% Termination Style PCB Unit Weight 9g Factory Packaging 3 Datasheet Product Datasheet

    1 pcs in stock

    $111.30
    $131.33 inclGST

  • AHR 2000 B420, Hall Effect Current Transducer, 2000A, 4-20mA True RMS output, 20-50VDC supply

    AHR 2000 B420, Hall Effect Current Transducer, 2000A, 4-20mA True RMS output, 20-50VDC supply

    16 pcs in stock

    LEM AHR 2000 B420, Hall Effect Current Transducer, 2000A, 4-20mA True RMS output, 20-50VDC supply Compact and versatile transducers for high AC and DC currents from 500 to 2000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features Split Core VFD and SCR waveforms current measurement True RMS output 4-20mA current output Busbar mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable or busbar up to 104 x 40mm High isolation between primary and secondary circuits Easy installation Applications -AC Power Supplies or Motors True RMS sensing - the most accurate way to monitor power supply or input power -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's and switch mode rectifiers. Current measurement gives faster response than temperature measurement. -Renewable Energy Installations or Backup Batteries Continuous condition monitoring allowing automatic failure detection and prediction -Application Domain Energy and Automation Specification LEM Part Number AHR 2000 B420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Nominal Current (RMS + DC) 2000 Amp Maximum Measurement Current (Peak) 3000 Amp Output 4-20mA Isolation 5.8kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 650g Factory Pack Qty 6   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    16 pcs in stock

    $764.70
    $902.35 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account