Fastron FRI 8-01/16, Current Monitoring Relay AC 1.6 - 16 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8-01/16 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 10 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/16
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
1.6 - 16 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1 x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current fl ow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Welding Diode Stack 150 Amp, 3 Phase 190 x 300 x 140mm Approx
Fastron Electronics Part Number
WST0001
Nominal Current
150
Peak Current
600
Leakage Current
<4mA
Forward Voltage
<1.3V
Rated Voltage
150VDC
Temperature Rise
<60°C
Mounting Torque
>12.5 N.M
Mounting
3 x M8 Studs Double Sided
Required Air Speed
3 m/s
Datasheet
Product Datasheet
Fastron FTH12053ZD3-P, Solid State Relay, 3 Phase 4-32VDC Control, 120A, 70-530VAC Load w/ Varistors 3 Phase Solid State Relays, with IP20 Cover
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Fastron Part Number
FTH12053ZD3-P
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
120 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator + Varistors for Overvoltage Protection, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Equivalent Parts
Contact Us for Possible Replacement
Â
Fastron FDH12048ZD1B, Solid State Relay, Contactor Style, 480VAC, 120 Amp, 3-32VDC Control, Zero Crossing, Panel Mount Power Module Style for 80mm rails
Ratings from 25A to 125 Amp @ 48-530VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Specification
Fastron Part Number
FDH12048ZD1B
Switching Type
Zero Crossing
CE
Yes
Control Voltage
3-32VDC
Load Current
120 Amp (rms)
Surge Capability
1100 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
90-480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
105g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Fastron FDH12048RD3, Solid State Relay, 480VAC, 120 Amp, 3-32VDC Control, Random Crossing, Panel Mount, w/plastic Cover
Ratings from 25A to 125 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Specification
Fastron Part Number
FDH12048ZD3
Switching Type
Zero Crossing
CE
Yes
Control Voltage
3-32VDC
Load Current
120Amp (rms)
Surge Capability
1100 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
90-480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
250g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Fastron FES003 AC Current Switch Relay
Compact and versatile current switches for detection of +1 Amp Current with maximum 40Amp.
Features
Self Powered
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES003
Technology
Split Core AC Current Transformer
Alarm Type
NC Relay 2.5Amp @ 120VAC
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 40 Amp
Trip Point
1A Locked
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Â
Datasheet
Product Datasheet
Â
Compact and versatile transducers for high Isolation Measurements of DC currents from 0 to 400 Amp DC (higher with external sensor) with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V
Features
VFD and SCR waveforms current measurement
Signal condtioned output
Din Rail mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1mA
High isolation between primary and secondary circuits
Easy installation
Applications
-VFD Controlled Loads
VFD output indicates how the motor and attached load are operating
-SCR Controlled Loads
Accurate measurement and control of DC Power Systems. Current measurement gives faster response than temperature measurement.
-Application Domain
Energy and Automation
Specification
Fastron Part Number
FES003 AC Current Switch
Technology
Closed Loop Hall Effect
Alarm Type
Relay NC 2.5A @ 230VAC
Supply Voltage
Self Powered
Load CurrentÂ
1Amp up to 40Amp
Output
0-10V, 0-5V, 0-20mA, 4-20mA
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
Din Rail Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
150g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
Â
Fastron FRTD-6-250-500 Resistance Temperature Detectors (RTD's)
Class B Accuracy
Pt100 output
Teflon Screened Cable
Low Long Term Drift
Rated for -50 to 350 Deg C Max
250 x 6mm
MIMS
Recommended to use BSP Fitting for mounting
Specification
Fastron Part Number
FRTD-6-250-500
Sensor Type
RTD - Resistance Temperature Detectors
No of Wires
3
Shaft Length
250mm
Shaft Thickness
6mm
Accuracy
Class B
Cable length
500cm
Cable Type
Teflon/Teflon
Terminal Head Type
N/A
Maximum Temperature
-50 to 350 Deg C
Special Feature
N/A
Mounting Style
BSP Bayonet or Flange Fitting Recommended
Weight
300g
Factory Pack Qty
1
Datasheet
Datasheet
1/8" BSPT x 5mm Compression Fitting for use with RTD or Thermocouple, SS 304 Body with Brass Compression Ring Insert
Tapered 1/8" BSP x 5mm
Stainless Steel
BSPT vs NPT Sizes
BSPT vs NPT Fittings