Trent FGM6DC-2PL-320 315A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 320 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 315A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
315 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-2PL-500 350A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 350 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-400 350A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
350 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
5.7kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-2PL-400 400A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 400 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-400 400A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
400 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
5.7kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6DC-2P-400, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6DC-2P-400
Functions
Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker Frame Size 400
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-2PL-320 125A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 125 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 125A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
125 Amps
Trip Delay Time
< 50ms
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu Ics=Icu
20kA @Â 1000VDC
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-3PL-320 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 315 Amp, 1500VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
Disconnect
20kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-3PL-320 315A
Functions
DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
315 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
3.3kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-2PL-320 250A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 250 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 250A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
250 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent ROT-FGM6-250, Extended Rotary Handle for 3 POLE MCCB FGM6-250 Frame Size
Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
Rotary handle mounts directly on MCCB with screws (included) without removal of midcover
Clear ON/OFF/TRIP
SuDirect access to push to trip button with rotary handle mounted
Datasheet
Product Datasheet
Trent FGM6DC-2PL-320 320A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 320 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 320A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
320 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-3PL-400 400A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 400 Amp, 1500VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
3 Pole Disconnect
25kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-3PL-400 400A
Functions
3 Pole DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
400 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
25kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-2PL-630 630A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-630 630A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
630 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
5.7kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-2PL-500 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 630 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-630 500A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
500 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet