Crydom HS211 + HD4850-10, Panel or slide on Din Rail Solid State Relay Random Crossing, 3-32VDC Control Input, 90-530VAC Output, 23 Amps
Features
Ratings from 25A to 125 Amp @48-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + HD4850-10
Switching Type
Random Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
23 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
48-530VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Â
Datasheet
HS211
HD4850-10
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
HS259DR + PMP4850WP, DIN Mount, Proportional Controller, 380-480VAC 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 90-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
HS259DR + PMP4850WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
25 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR + Overvvoltage Protection
Mounting Style
Panel Mount
Load Voltage Range
345-530VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
0.4kg
Factory Pack Qty
20
Â
Datasheet
PMP24 Series Datasheet
PMP24 Installation/Wiring Guide
GFIN
Equivalent Parts
Contact Us for Possible Replacement
Â
Crydom PMP4890WP, Phase/Burst control, 240VAC, 90 Amp, Selectable 0-5V,0-10V,4-20mA Input, w/Overvoltage Protection
Features
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
PMP4890WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
90 Amp (rms)
Surge Capability
1290Amp (peak)
Special Feature
Proportional Controller + SSR, Overvoltage protection
Mounting Style
Panel Mount
Load Voltage Range
345-530VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
160g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
PMP24 Installation/Wiring Guide
Equivalent
Crydom PMP2425W or Contact Us for Possible Replacement
Â
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
GFIN/70M-DR + PMP4850WP DIN Mount, Proportional Controller, 370-480VAC 40 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
Selectable Proportional Phase or Burst Control Input
Ratings from 25A to 90 Amp @ 170-600 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
GFIN/70M-DR + PMP4850WP
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable)
Note Requires DC Power Supply for 0-5V/0-10V input modes
Load Current
40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR + Overvvoltage Protection
Mounting Style
Panel Mount
Load Voltage Range
345-530VAC
Dielectric Strength
4kV
Termination Style
Terminal Plug
Unit Weight
1000g
Factory Pack Qty
20
Â
Datasheet
PMP24 Series Datasheet
PMP24 Installation/Wiring Guide
GFIN
Equivalent Parts
Contact Us for Possible Replacement
Â
Fastron H31/110M + FTH6053ZA4, Three Phase Solid State Relay 90-280VAC Control, 3 x 34Amp, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Fastron Part Number
H31/110M + FTH6053ZA4
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 34 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Dimensions
L:110 x W:125 x D:180mm
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
3kg
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
H31 Datasheet
Fastron H31/110M-B + FTH6053ZD3, Three Phase Solid State Relay with Heatsink 4-32VDC Control, 3 x 34Amp @ 40 Deg C, 48-530VAC Load, with IP20 Cover
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Fastron Part Number
H31/110M + FTH6053ZD3
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 34 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Dimensions
L:110 x W:125 x D:180mm
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
H31 Datasheet
DR6760D25P, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, Zero Crossing, 25 Amp per phase @ 40 Deg C, 48-600VAC Load, LED Status Indicator, Overvoltage Protection
Features
Ratings from 25A to 30 Amp @ 70-530 VAC
Motor Control
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DR6760D25P
Switching Type
Random Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 25 Amp (rms) per Phase @ 30 DeG C
Surge Capability
716 Amp (peak)
Special Feature
LED Status Indicator, Overvoltage Protection
Mounting Style
Din Rail Mount
Load Voltage Range
48-600VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
961g
Factory Pack Qty
10
Â
Datasheet
DR6760D30P
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
DR6760D30P, Solid State Relay and Heatsink Assembly, 3 Phase, 2 Leg Control, 4-32VDC Control, Random Crossing, 30 Amp per phase @ 40 Deg C, 48-600VAC Load, LED Status Indicator, Overvoltage Protection
Features
Ratings from 25A to 60 Amp @ 70-530 VAC
Motor Control
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DR6760DR30P
Switching Type
Random Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 30 Amp (rms) per Phase @ 30 DeG C
Surge Capability
716 Amp (peak)
Special Feature
LED Status Indicator, Overvoltage Protection
Mounting Style
Din Rail Mount
Load Voltage Range
48-600VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
961g
Factory Pack Qty
10
Â
Datasheet
DR6760D30P
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Crydom DR2260A20V, Solid State Contactor SSR, Single Phase 90-280VAC Control, 20A, 48-600VAC Load, Din Rail Mount
Features
Ratings from 20A to 35 Amp @ 48-660 VAC
Contactor Style for retrofit
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DR2260A20V
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90-280VAC
Load Current (single unit)
20 Amp (rms) @ 40 Deg C Ambient, 16 Amp (rms) @ 50 Deg C Ambient
Load Current (multiple units)
20 Amp (rms) @ 40 Deg C Ambient, 16 Amp (rms) @ 50 Deg C Ambient
Surge Capability
286 Amp (peak)
Special Feature
Contactor Style Terminals
Mounting Style
DIN Rail Mount
Load Voltage Range
48 - 660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
298g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Alternatives
SSR Style CKRD4830
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron HS212F & FCR-400-40R, Three Phase, Phase Angle Controller, 4-20mA,0-10V,500K POT Input, 400VAC, 36 Amp @ 40 Deg C, Din Rail Mount
4-20mA, 0-10V or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
HS212F & FCR-400-40R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
36 Amp (rms) per phase @ 40 Deg C
Surge Capability
500Amp (peak)
Special Feature
Three Phase Proportional Controller
Mounting Style
DIN Rail Mount
Load Voltage Range
350-400VAC +15% (460VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
100 x 135 x 130mm
Unit Weight
1500g
Factory Pack Qty
20
Â
Datasheet
FCR Series Voltage Regulators
HS212 Datasheet
Fastron HS212DR-F & FCR-400-40R, Three Phase, Phase Angle Controller, 4-20mA,0-10V,500K POT Input, 400VAC, 36 Amp @ 40 Deg C, Din Rail Mount
4-20mA, 0-10V or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
HS212DR-F & FCR-400-40R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
36 Amp (rms) per phase @ 40 Deg C
Surge Capability
500Amp (peak)
Special Feature
Three Phase Proportional Controller
Mounting Style
DIN Rail Mount
Load Voltage Range
350-400VAC +15% (460VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
100 x 135 x 130mm
Unit Weight
1500g
Factory Pack Qty
20
Â
Datasheet
FCR Series Voltage Regulators
HS212 Datasheet
Fastron HS212DR-F & FCR-400-40R-5, Three Phase, Phase Angle Controller, 4-20mA,0-5V,500K POT Input, 400VAC, 20 Amp @ 40 Deg C, Din Rail Mount
4-20mA,0-10V, 0-5V or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
HS212DR-F & FCR-400-40R-5
Switching Type
Phase Angle (Random Crossing)/ Burst Fire (10 cycles)
Control Voltage
4-20mA,0-5V,500K POT Proportional Input
Load Current
36 Amp (rms) per phase @ 40 Deg C
Surge Capability
690Amp (peak)
Special Feature
Three Phase Proportional Controller
Mounting Style
DIN Rail Mount
Load Voltage Range
350-400VAC +15% (460VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
100 x 135 x 130mm
Unit Weight
1500g
Factory Pack Qty
20
Â
Datasheet
FCR Series Voltage Regulators
HS212 Datasheet