Railway Voltage Sensors

46 products

  • DVM 4200 Digital Voltage Transducer, Vpn = 4200V, +/-12...24VDC, 72mA output, 12kV Isolation

    DVM 4200 Digital Voltage Transducer, Vpn = 4200V, +/-12...24VDC, 72mA output, 12kV Isolation

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVM 4200 Digital Voltage Transducer, Vpn = 4200V, +/-12...24VDC, 50mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-4200 Specification LEM Part Number DVM 4200 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/-4200V Measurement Range +/- 6000V Output 72 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 0.8% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $1,114.00
    $1,314.52 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVM 4000-B Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 50mA output, 12kV Isolation FE-DVM 4000-B

    DVM 4000-B Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 6.66V output, 12kV Isolation

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVM 4000-B Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 6.66V output, 12kV Isolation Features Bandwidth DC to 13kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVM 4000-B Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/-4000V Measurement Range +/- 6000V Output 6.66V @ +/- Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw, M5 Inserts on Input Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $1,160.40
    $1,369.27 inclGST

  • DVM 4000 Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 75mA output, 12kV Isolation

    DVM 4000 Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 75mA output, 12kV Isolation

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVM 4000 Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 75mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-4000 Specification LEM Part Number DVM 4000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 4000V Measurement Range +/- 6000V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $1,114.00
    $1,314.52 inclGST

  • DVM 3600 Digital Voltage Transducer, Vpn = 3600V, +/-12...24VDC, 75mA output, 12kV Isolation

    DVM 3600 Digital Voltage Transducer, Vpn = 3600V, +/-12...24VDC, 75mA output, 12kV Isolation

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVM 3600 Digital Voltage Transducer, Vpn = 3600V, +/-12...24VDC, 75mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-3600 Specification LEM Part Number DVM 3600 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 3600V Measurement Range +/- 5400V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $1,114.00
    $1,314.52 inclGST

  • DVM 3000 Digital Voltage Transducer, Vpn = 3000V, +/-12...24VDC, 75mA output, 12kV Isolation

    DVM 3000 Digital Voltage Transducer, Vpn = 3000V, +/-12...24VDC, 75mA output, 12kV Isolation

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVM 3000 Digital Voltage Transducer, Vpn = 3000V, +/-12...24VDC, 50mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-3000 Specification LEM Part Number DVM 3000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 3000V Measurement Range +/- 4500V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $1,114.00
    $1,314.52 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 50mA output, 12kV Isolation FE-DVM 2000

    DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 75mA output, 12kV Isolation

    18 pcs in stock

    LEM DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 75mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Drop in Replacment for LV100-2000/SP6 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-2000 Specification LEM Part Number DVM 2000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    18 pcs in stock

    $1,078.00
    $1,272.04 inclGST

  • DVM 1000 Digital Voltage Transducer, Vpn = 1000V, +/-12...24VDC, 75mA output, 12kV Isolation

    DVM 1000 Digital Voltage Transducer, Vpn = 1000V, +/-12...24VDC, 75mA output, 12kV Isolation

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVM 1000 Digital Voltage Transducer, Vpn = 1000V, +/-12...24VDC, 75mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-1000 Specification LEM Part Number DVM 1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $929.00
    $1,096.22 inclGST

  • DVL 750 Digital Voltage Transducer, Vpn = 750V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    DVL 750 Digital Voltage Transducer, Vpn = 750V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    12 pcs in stock

    LEM DVL 750 Digital Voltage Transducer, Vpn = 750V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 750 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 750V Measurement Range +/- 1125V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    12 pcs in stock

    $551.00
    $650.18 inclGST

  • DVL 50 Digital Voltage Transducer, Vpn = 50V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    DVL 50 Digital Voltage Transducer, Vpn = 50V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    12 pcs in stock

    LEM DVL 50 Digital Voltage Transducer, Vpn = 50V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 50 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 50V Measurement Range +/- 75V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    12 pcs in stock

    $551.00
    $650.18 inclGST

  • DVL 250 Digital Voltage Transducer, Vpn = 250V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    DVL 250 Digital Voltage Transducer, Vpn = 250V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 250 Digital Voltage Transducer, Vpn = 250V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 250 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 250V Measurement Range +/- 375V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $551.00
    $650.18 inclGST

  • DVL 2000/SP6 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Output connection cable

    DVL 2000/SP6 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Output connection cable

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 2000/SP6 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Output connection cable Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Output connection cable Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 2000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Output connection cable Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $609.00
    $718.62 inclGST

  • DVL 2000/SP5 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables

    DVL 2000/SP5 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 2000/SP5 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Input and output cables Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 2000/SP5 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Input and output cables Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $689.00
    $813.02 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account