Railway Voltage Sensors

46 products

  • DV 1200/SP2 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    DV 1200/SP2 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    Out of stock

    LEM DV 1200/SP2 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-2000 Specification LEM Part Number DV 1200/SP2 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1200V Measurement Range +/- 1800V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $1,564.00
    $1,845.52 inclGST

  • DV 1000 Digital Voltage Transducer, Vpn = 1000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    DV 1000 Digital Voltage Transducer, Vpn = 1000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    Out of stock

    LEM DV 1000 Digital Voltage Transducer, Vpn = 1000V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-2000 Specification LEM Part Number DV 1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $1,564.00
    $1,845.52 inclGST

  • DV 2000 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    DV 2000 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation

    Out of stock

    LEM DV 2000 Digital Voltage Transducer, Vpn = 2000V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-2000 Specification LEM Part Number DV 2000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 Meters Flying leads Unit Weight 1000g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $1,564.00
    $1,845.52 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVL 1000 UI, Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation FE-DVL1000 UI

    DVL 150 UI, Digital Voltage Transducer 150V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation

    Out of stock

    LEM DVL 150 UI, Digital Voltage Transducer 150V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 150 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 150V Measurement Range +/- 225V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $661.00
    $779.98 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVL 1000 UI, Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation FE-DVL1000 UI

    DVL 50 UI, Digital Voltage Transducer 50V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation

    Out of stock

    LEM DVL 50 UI, Digital Voltage Transducer 50V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 50 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 50V Measurement Range +/- 75V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $661.00
    $779.98 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVL 1000 UI, Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation FE-DVL1000 UI

    DVL 250 UI, Digital Voltage Transducer 250V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation

    Out of stock

    LEM DVL 250 UI, Digital Voltage Transducer 250V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 250 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 250V Measurement Range +/- 375V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $661.00
    $779.98 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVL 1000 UI, Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation FE-DVL1000 UI

    DVL 750 UI, Digital Voltage Transducer 750V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation

    12 pcs in stock

    LEM DVL 750 UI, Digital Voltage Transducer 750V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 750 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 750V Measurement Range +/- 1125V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    12 pcs in stock

    $661.00
    $779.98 inclGST

  • DVL 750/SP5 Digital Voltage Transducer, Vpn = 750V, 0-10V output, +/-15...24VDC powered, 8.5kV Isolation

    DVL 750/SP5 Digital Voltage Transducer, Vpn = 750V, 0-10V output, +/-15...24VDC powered, 8.5kV Isolation

    Out of stock , More available in 6-8 weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 750/SP5 Digital Voltage Transducer, Vpn = 750V, 0-10V output, +/-15...24VDC powered, 8.5kV Isolation Features SP5 = M5 Inserts for seconday and 0-10V output measurement range Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 750/SP5 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 750V Measurement Range +/- 1125V Output 0- 7.5 V @Vpn (0-10V range) Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 6-8 weeks

    Free Aus Post Shipping for $300 Spend

    $757.90
    $894.32 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 50mA output, 12kV Isolation FE-DVM 2000

    DVM 4000-UI, Digital Voltage Transducer, Vpn = 4000V, 24VDC Supply, 4-20mA Analogue Output, 12kV Isolation

    6 pcs in stock

    LEM DVM 4000-UI, Digital Voltage Transducer, Vpn = 4000V, 24VDC Supply, 4-20mA Analogue Output, 12kV Isolation Features Bandwidth DC to 13kHz 4-20mA Unipolar Analogue Output Closed loop transducer using Hall effect Digital Transducer Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVM 4000-UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage 24 VDC, Isolated Primary Nominal Voltage (RMS + DC) +/- 4000V Measurement Range +/- 6000V Output 4 mA at 0V, to 20mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    6 pcs in stock

    $1,547.70
    $1,826.29 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVM 4000-B Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 50mA output, 12kV Isolation FE-DVM 4000-B

    DVM 2000-B, Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 6.66V output, 12kV Isolation

    Out of stock , More available in 6-8 weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVM 2000-B, Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 6.66V output, 12kV Isolation Features Bandwidth DC to 13kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVM 2000-B Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/-2000V Measurement Range +/- 3000V Output 6.66V @ +/- Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw, M5 Inserts on Input Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 6-8 weeks

    Free Aus Post Shipping for $300 Spend

    $1,010.90
    $1,192.86 inclGST

  • LEM International SA AC/DC Voltage Hall Effect Sensor DVL 1000 UI, Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation FE-DVL1000 UI

    DVL 1500 UI, Voltage Transducer 1500V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation

    24 pcs in stock

    LEM DVL 1500 UI, Voltage Transducer 1500V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1500 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1500V Measurement Range +/- 2250V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    24 pcs in stock

    $661.00
    $779.98 inclGST

  • DVM 600 Digital Voltage Transducer, Vpn = 600V, +/-12...24VDC, 50mA output, 12kV Isolation

    DVM 600 Digital Voltage Transducer, Vpn = 600V, +/-12...24VDC, 50mA output, 12kV Isolation

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVM 600 Digital Voltage Transducer, Vpn = 600V, +/-12...24VDC, 50mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-600 Specification LEM Part Number DVM 600 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 600V Measurement Range +/- 900V Output 50 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $929.00
    $1,096.22 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account