Appliance Thermal Circuit Breakers

51 products

  • Last stock! 4400.0114 T11-811-5, 1 Pole Thermal Circuit Breaker, 240VAC/48VDC, 5 Amp, 2kA, Drop In, Reset Type, Fastron Terminals

    4400.0114 T11-811-5, 1 Pole Thermal Circuit Breaker, 240VAC/48VDC, 5 Amp, 2kA, Drop In, Reset Type, Fastron Terminals

    1 pcs in stock

    Schurter, 4400.0114 T11-811-5, 1 Pole Thermal Circuit Breaker, 240VAC/48VDC, 5 Amp, 2kA, Drop In, Reset Type, Fastron Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0114 T11-811-5 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 5 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    1 pcs in stock

    $16.50
    $19.47 inclGST

  • 3-146-121 (T12-121SR-8), 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts & Indicator Tag

    3-146-121 (T12-121SR-8), 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts & Indicator Tag

    25 pcs in stock

    Schurter, 3-146-121 (T12-121SR-8), 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts & Indicator Tag Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Indicator Ribbon/Tag Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 3-146-121 (T12-121SR-8) Functions 1 Pole Thermal Circuit Breaker Button Action Manual ON/OFF Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    25 pcs in stock

    $59.70
    $70.45 inclGST

  • 4410.0015 T12-221-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals-Circuit Breaker-Schurter-Fastron Electronics Store

    4410.0106 T12-211S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts

    Out of stock

    churter, 4410.0106 T12-211S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0147 (T12-221S-10) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 10 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $58.70
    $69.27 inclGST

  • 3-137-183 T12-121S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts

    3-137-183 T12-121S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts

    14 pcs in stock

    Schurter, 3-137-183 T12-121S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Flange type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 3-137-183 (T12-121S-8) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    14 pcs in stock

    $58.70
    $69.27 inclGST

  • 4410.0015 T12-221-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals-Circuit Breaker-Schurter-Fastron Electronics Store

    4410.0695 T12-221S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts

    Out of stock

    Schurter, 4410.0695 T12-221S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0695 (T12-221S-8) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    Out of stock

    $58.70
    $69.27 inclGST

  • 4410.0015 T12-221-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals-Circuit Breaker-Schurter-Fastron Electronics Store

    4410.0147 T12-221S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contacts

    Out of stock

    Schurter, 1 Pole 10 Amp, 1kA Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/Auxiliary Contacts 4410.0147 T12-221S-10 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Auxiliary Contacts Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0147 (T12-221S-10) Functions 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 10 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    Out of stock

    $58.70
    $69.27 inclGST

  • 4410.0826 T12-111S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts

    4410.0826 T12-111S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts

    Out of stock

    Schurter 4410.0826 T12-111S-10, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 10 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description 40mm Panel Mount Type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0826 T12-111S-10 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 10 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Mounting Panel Mount 40mm hole centres Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    Out of stock

    $53.70
    $63.37 inclGST

  • 4410.0711 T12-111S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts

    4410.0711 T12-111S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts

    Out of stock

    Schurter 4410.0711 T12-111S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, 40mm Panel Mount, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description 40mm Panel Mount Type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0711 T12-111S-8 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Mounting Panel Mount 40mm hole centres Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    Out of stock

    $53.70
    $63.37 inclGST

  • 4410.0084 T12-211S-1, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 1 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact

    4410.0084 T12-211S-1, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 1 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact

    16 pcs in stock

    Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 0.8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts 4410.0084 T12-211S-1 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0084 T12-211S-1 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 1 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    16 pcs in stock

    $58.70
    $69.27 inclGST

  • 4410.0215 T12-221S-2, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contact-Circuit Breaker-Schurter-Fastron Electronics Store

    4410.0215 T12-221S-2, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contact

    19 pcs in stock

    Schurter, 4410.0215 T12-221S-2, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contact Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0215 T12-221S-2 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Manual ON/OFF Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 2 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    19 pcs in stock

    $58.70
    $69.27 inclGST

  • 4410.0131 T12-211S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact

    4410.0131 T12-211S-8, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact

    20 pcs in stock

    Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts 4410.0131 T12-211S-8 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0131 T12-211S-8 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    20 pcs in stock

    $58.70
    $69.27 inclGST

  • 4410.0439 T12-211S-2, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact

    4410.0439 T12-211S-2, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contact

    20 pcs in stock

    Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts 4410.0439 T12-211S-2 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole with Auxiliary Contact- Motors Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect with Auxiliary Contact 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4410.0439 T12-211S-2 Functions 1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 2 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 4kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet

    20 pcs in stock

    $58.70
    $69.27 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account