Appliance Thermal Circuit Breakers

51 products

  • 4400.0055 T11-211-1.2, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 1.2 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0055 T11-211-1.2, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 1.2 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    79 pcs in stock

    4400.0055 T11-211-1.2, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 1.2 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0055 T11-211-1.2 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 1.2 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    79 pcs in stock

    $16.50
    $19.47 inclGST

  • 4400.0052 T11-211-12, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 12 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0052 T11-211-12, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 12 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    35 pcs in stock

    4400.0052 T11-211-12 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 12 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0052 T11-211-12 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 12 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    35 pcs in stock

    $16.50
    $19.47 inclGST

  • 4400.0050 T11-211-6, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 6 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0050 T11-211-6, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 6 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    73 pcs in stock

    4400.0050 T11-211-6, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 6 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0050 T11-211-6 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 6 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    73 pcs in stock

    $16.50
    $19.47 inclGST

  • 4400.0047 T11-211-2, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 2 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0047 T11-211-2, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 2 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    78 pcs in stock

    4400.0047 T11-211-2 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 2 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0047 T11-211-2 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 2 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    78 pcs in stock

    $16.50
    $19.47 inclGST

  • 4400.0043 T13-212-15, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 15 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles

    4400.0043 T13-212-15, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 15 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles

    Out of stock

    4400.0043, T13-212-15 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 15 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, 2 x Ir_3000 Switching Cycles Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a dis-connector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 3000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0043 T13-212-15 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 15 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $34.50
    $40.71 inclGST

  • 4400.0042 T11-211-0.8, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.8 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0042 T11-211-0.8, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.8 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    100 pcs in stock

    4400.0042 T11-211-0.8 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 0.8 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0042 T11-211-0.8 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 0.8 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    100 pcs in stock

    $16.50
    $19.47 inclGST

  • 4400.0041 T11-211-4.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 4.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0041 T11-211-4.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 4.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    99 pcs in stock

    4400.0041 T11-211-4.5 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 4.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0041 T11-211-4.5 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 4.5 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    99 pcs in stock

    $16.50
    $19.47 inclGST

  • 4400.0010 T11-211-3, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 3 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0010 T11-211-3, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 3 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    Out of stock

    4400.0010 T11-211-3 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 3 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0010 T11-211-3 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 3 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $16.50
    $19.47 inclGST

  • 4400.0009 T11-211-2.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 2.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0009 T11-211-2.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 2.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    Out of stock

    4400.0009 T11-211-2.5, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 2.5 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0009 T11-211-2.5 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 2.5 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $16.50
    $19.47 inclGST

  • 4400.0008 T11-211-1.0 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 1.0 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    4400.0008 T11-211-1.0 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 1.0 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals

    Out of stock

    4400.0008 T11-211-1.0 Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 1.0 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0008 T11-211-1.0 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 1 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $16.50
    $19.47 inclGST

  • 4400.0006 T11-211-5, 1 Pole Thermal Circuit Breaker, 240VAC/48VDC, 5 Amp, 2kA, Threaded neck, Reset Type, Fastron Terminals

    4400.0006 T11-211-5, 1 Pole Thermal Circuit Breaker, 240VAC/48VDC, 5 Amp, 2kA, Threaded neck, Reset Type, Fastron Terminals

    Out of stock

    4400.0001 T11-211-5, 1 Pole Thermal Circuit Breaker, 240VAC/48VDC, 4 Amp, 2kA, Threaded neck, Reset Type, Fastron Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0003 T11-211-10 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 5 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $16.50
    $19.47 inclGST

  • 4400.0001 T11-211-4, 1 Pole Thermal Circuit Breaker, 240VAC/48VDC, 4 Amp, 2kA, Threaded neck, Reset Type, Fastron Terminals

    4400.0001 T11-211-4, 1 Pole Thermal Circuit Breaker, 240VAC/48VDC, 4 Amp, 2kA, Threaded neck, Reset Type, Fastron Terminals

    Out of stock

    4400.0001 T11-211-4, 1 Pole Thermal Circuit Breaker, 240VAC/48VDC, 4 Amp, 2kA, Threaded neck, Reset Type, Fastron Terminals Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Threaded neck type Thermal circuit breaker 1-pole - Power tools Reset type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 2kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 500 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4400.0003 T11-211-10 Functions 1 Pole Thermal Circuit Breaker, Reset Type Nominal Voltage 240VAC @ 50Hz or 48VDC Nominal Current Range 4 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -5 to 60 Deg C Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 2kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $16.50
    $19.47 inclGST

Login

Forgot your password?

Don't have an account yet?