LEM AK 200 C420L Series Average RMS Solid Core AC Current Sensor with Process Outputs
Compact and versatile Solid Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V
Features
Solid Core
Average RMS output
4-20mA current output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀19mm
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
AK 200 C420L,
Technology
AC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
24VDC Loop Powered
Nominal Current (RMS + DC)
100,150,200 Amp Selectable
Maximum Measurement Current (Peak)
120,180,240 Amp
Output
4-20mA Average RMS
Aperture
⌀19mm
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
2 x UNC8 Cylindric Head
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM AK 200 C10 Series Solid Core AC/DC Hall Effect Sensor with Process Outputs
Compact and versatile Solid Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V
Features
Solid Core
Average RMS output
0-10V voltage output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀19mm
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will nto drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
AK 200 C10
Technology
AC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
Self Powered
Nominal Current (RMS + DC)
100,150,200 Amp Selectable
Maximum Measurement Current (Peak)
120,180,240 Amp
Output
0-10V Average RMS
Aperture
⌀19mm
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
2 x UNC8 Cylindric Head
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM AK 200 B420L Series Average RMS Split Core AC Current Sensor with Process Outputs
Compact and versatile Split Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V
Features
Split Core
Average RMS output
4-20mA current output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 21.7mm sqr
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
AK 200 B420L
Technology
AC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
24VDC Loop Powered
Nominal Current (RMS + DC)
100,150, 200 Amp Selectable
Maximum Measurement Current (Peak)
120,180,240 Amp
Output
4-20mA Average RMS
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
2 x UNC8 Cylindric Head
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM AK 200 B10 Series Average RMS Split Core AC Current Sensor with Process Outputs
Compact and versatile Split Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V
Features
Split Core
Average RMS output
0-10V voltage output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 21.7mm sqr
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
AK 200 B10
Technology
AC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
Self Powered
Nominal Current (RMS + DC)
100,150,200 Amp Selectable
Maximum Measurement Current (Peak)
120,180,240 Amp
Output
0-10V Average RMS
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
2 x UNC8 Cylindric Head
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Rishabh Xmer CT Split 155/80 1200/5 Class 0.5 15VA Series Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 155/80 1200/5 SCCT Class 0.5 15VA
Technology
Split Core AC Current Transformer
Ratio
1200/5
Aperture Size
85 x 125mm
VA Rating
15VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Xmer CT Split 155/80 1200/5 Class 1 30VA Series Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 155/80 1200/5 SCCT Class 1 30VA
Technology
Split Core AC Current Transformer
Ratio
1200/5
Aperture Size
85 x 125mm
VA Rating
30VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet
LEM TT 50-SD Series Current Transformer (, Obsolete)
Features
Quick Release Split Core System
Ø 8 mm sensing aperture for noncontact measurementMounting Feet Supplied
Self Powered
Cable output (1m)
Rated System Voltage 0.30/3.5kV
Isolated plastic case recognized according to UL 94-V0
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
LEM Part Number
TT 50-SD
Technology
Split Core AC Current Transformer
Ratio
50/16.66mA
Aperture Size
? 8mm
Protection Degree
IP40
Accuracy Class
Class 1
Output
16.66 mA AC (+20%)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
50Amp x 1.2
Termination Style
1m Flying Lead
Unit Weight
80g
Factory Pack Qty
9
Datasheet
Product Datasheet
Alternatives
This part is , Obsolete. Contact Us for Possible Replacement for replacement
Rishabh Rish Xmer 62-R 100/5 Series Class 0.2 Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 62-R 100/5 Class 0.2
Technology
AC Current Transformer
Ratio
100/5
Aperture Size
⌀ 22mm
VA Rating
1.5VA
Accuracy Class
Class 0.2
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
100Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Rish Xmer 140-100H (45) 2500/5 Class 1 Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 140-100H (45) 2500/5 Class 1
Technology
AC Current Transformer
Ratio
2500/5
Aperture Size
⌀ 86mm or 101 x 31mm Busbar
VA Rating
45VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
2500Amp x 1.2
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Rish Xmer 86-50 (45) 1200/5 Class 1 30VA Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 86-50 (45) 1200/5 Class 1
Technology
AC Current Transformer
Ratio
1200/5
Aperture Size
⌀ 46mm or 51 x 12mm Busbar
VA Rating
30VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
1200Amp x 1.2
Termination Style
Screw
Unit Weight
0.9kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Rish Xmer 104-80 (45) 1500/5 Class 1 Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 104-80 (45) 1500/5 Class 1
Technology
AC Current Transformer
Ratio
1500/5
Aperture Size
⌀ 65mm or 85 x 12mm Busbar
VA Rating
30VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
1500Amp x 1.2
Termination Style
Screw
Unit Weight
0.9kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Rish Xmer 140-100H (45) 2000/5 Class 1 Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 140-100H (45) 2000/5 Class 1
Technology
AC Current Transformer
Ratio
2000/5
Aperture Size
⌀ 65mm or 85 x 12mm Busbar
VA Rating
45VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
2000Amp x 1.2
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
9
Datasheet
Product Datasheet