Current Transformers Australia

247 products

  • FES2151-FP-420T, Split Core AC Current Transducer, Multirange 100A,150A, 200A, Self Powered, True RMS 4-20mA Output. 1% Accuracy Fastron Electronics Current Transformer with Process Output FES2151-FP-420T, AC Current Transducer, Multirange 100A,150A, 200A, Self Powered, True RMS 4-20mA Output. 1% Accuracy FE-FES521-FP-420T

    FES2151-FP-420T, Split Core AC Current Transducer, Multirange 100A,150A, 200A, Self Powered, True RMS 4-20mA Output. 1% Accuracy

    70 pcs in stock

    Fastron FES2151-FP-420T, Split Core AC Current Transducer, Multirange 100A,150A, 200A, Self Powered, True RMS 4-20mA Output. 1% Accuracy Compact and versatile current switches for detection of AC Currents, Multirange 0-100Amp, 0-150Amp, 0-200Amp via jumper, 4-20mA True RMS output Features True RMS 4-20mA output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES2151-FP-420T Technology Split Core AC Current Transducer Range 0-100Amp, 0-150Amp, 0-200Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 200 Amp Output 4-20mA True RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant Datasheet Product Datasheet Installation Guide

    70 pcs in stock

    $119.00
    $140.42 inclGST

  • Rish Xmer Split Core 4000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture Rish Xmer Split Core 4000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture

    Rish Xmer Split Core 4000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture

    12 pcs in stock

    Rish Xmer Split Core 4000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number Rish Xmer Split Core 4000/5 195/80 Technology Split Core AC Current Transformer Ratio 4000/5 Aperture Size 172 x 85mm VA Rating 45VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9 Datasheet Product Datasheet

    12 pcs in stock

    $383.00
    $451.94 inclGST

  • Rish Xmer Split Core 3000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture Rish Xmer Split Core 3000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture

    Rish Xmer Split Core 3000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture

    12 pcs in stock

    Rish Xmer Split Core 3000/5 Amp 195/80 Class 0.5, 30VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Electronics Part Number Rish Xmer Split Core 3000/5 195/80 Technology Split Core AC Current Transformer Ratio 3000/5 Aperture Size 172 x 85mm VA Rating 45VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9   Datasheet Product Datasheet

    12 pcs in stock

    $383.00
    $451.94 inclGST

  • Rish Xmer 195/80 2500/5 Split Core CT Class 0.5 25VA, 85 x 172mm Aperture Rish Xmer 195/80 2500/5 Split Core CT Class 0.5 25VA, 85 x 172mm Aperture

    Rish Xmer 195/80 2500/5 Split Core CT Class 0.5 25VA, 85 x 172mm Aperture

    12 pcs in stock

    Rish Xmer Split Core 2500/5 Amp 195/80 Class 0.5, 25VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Electronics Part Number Rish Xmer Split Core 2500/5 195/80 Technology Split Core AC Current Transformer Ratio 2500/5 Aperture Size 172 x 85mm VA Rating 25VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9   Datasheet Product Datasheet

    12 pcs in stock

    $383.00
    $451.94 inclGST

  • FT150160P, 1500/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm FT150160P, 1500/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm

    FT150160P, 1500/5 Amp Split Core CT, Class 0.5 15VA, 80 x 160mm Aperture, Dimensions 185 x 53 x 248mm

    Out of stock

    FT150160P, 1500/5 Amp Split Core CT, Class 0.5 15VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Electronics Part Number FT150160P Technology Split Core AC Current Transformer Ratio 1500/5 Aperture Size 80 x 160mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Unit Weight 2.7kg Factory Pack Qty 1   Datasheet Product Datasheet Installation Guide  

    Out of stock

    $281.00
    $331.58 inclGST

  • CT 75/5 Class 1 2.5VA 45/21(40) Current Transformer CT 75/5 Class 1 2.5VA 45/21(40) Current Transformer

    CT 75/5 Class 1 2.5VA 45/21(40) Current Transformer

    24 pcs in stock

    Rishabh CT 75/5 Class 1 2.5VA 45/21(40) Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 75/5 Class 1 2.5VA 45/21 (40) Technology AC Current Transformer Ratio 75/5 Aperture Size ⌀ 21mm or 20x10mm Busbar VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet

    24 pcs in stock

    $36.00
    $42.48 inclGST

  • Rishabh Instruments AC Current Transformer Rish Xmer 140-100H (45) 2500/5 Class 1 FE-Rish Xmer 140-100H (45) 2500/5 Class 1 Rish Xmer 140-100H (45) 2500/5 Class 0.5, 45VA, ⌀ 86mm or 101 x 31mm Busbar

    Rish Xmer 140-100H (45) 2500/5 Class 0.5, 45VA, ⌀ 86mm or 101 x 31mm Busbar

    Out of stock

    Rishabh Rish Xmer 140-100H (45) 2500/5 Class 0.5 Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 140-100H (45) 2500/5 Class 0.5 Technology AC Current Transformer Ratio 2500/5 Aperture Size ⌀ 86mm or 101 x 31mm Busbar VA Rating 45VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2500Amp x 1.2 Termination Style Screw Unit Weight 1.2kg Factory Pack Qty 9 Datasheet Product Datasheet

    Out of stock

    $124.70
    $147.15 inclGST

  • Rishabh Instruments AC Current Transformer Rish Xmer 104-80 (45) 1500/5 Class 1 FE-Rish Xmer 104-80 (45) 1500/5 Class 1 Rish Xmer 104-80 (45) 1500/5 Class 0.5, 20VA, ⌀ 65mm or 85 x 12mm Busbar

    Rish Xmer 104-80 (45) 1500/5 Class 0.5, 20VA, ⌀ 65mm or 85 x 12mm Busbar

    Out of stock

    Rishabh Rish Xmer 104-80 (45) 1500/5 Class 0.5 Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 104-80 (45) 1500/5 Class 0.5 Technology AC Current Transformer Ratio 1500/5 Aperture Size ⌀ 65mm or 85 x 12mm Busbar VA Rating 20VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9 Datasheet Product Datasheet

    Out of stock

    $96.00
    $113.28 inclGST

  • APR 50 B10, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 10V output, Infinite Overload Capability

    APR 50 B10, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 10V output, Infinite Overload Capability

    Out of stock

    LEM APR 50 B10, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 10V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 10, 20, 50 Amp True RMS. Selectable 0-5V, 0-10V output Features Split Core True RMS output 0-10V/0-5V voltage output Busbar, or Din Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number APR 50 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 10,20,50 Amp Selectable Overload Infinite Output 0-10V/0-5V True RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $315.00
    $371.70 inclGST

  • AP 400 B420L, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 4-20mA output, Infinite Overload Capability

    AP 400 B420L, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 4-20mA output, Infinite Overload Capability

    14 pcs in stock

    LEM AP 400 B420L, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 4-20mA output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 200, 300, 400 Amp Average RMS 4-20mA output Features Split Core Average RMS output 4-20mA current output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 400 B420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 200,300,400 Amp Selectable Overload Infinite Output 4-20mA Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    14 pcs in stock

    $282.00
    $332.76 inclGST

  • AP 400 B10, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 10V/5V output, Infinite Overload Capability

    AP 400 B10, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 10V/5V output, Infinite Overload Capability

    Out of stock

    LEM AP 400 B10, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, Average RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 200, 300, 400 Amp Average RMS. Selectable 0-5V, 0-10V output Features Split Core Average RMS output 0-10V/0-5V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 400 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 200,300,400 Amp Selectable Overload Infinite Output 0-10V/0-5V Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $259.00
    $305.62 inclGST

  • AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability

    AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability

    Out of stock

    LEM AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Selectable 0-5V, 0-10V output Features Split Core Average RMS output 0-10V/0-5V voltage output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 200 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 100,150, 200 Amp Selectable Overload Infinite Output 0-10V/0-5V Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $226.04
    $266.73 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account