Search results for "tg�� banonpi ���湮���ϴ��� �ٳ������ɳ����� ���νñ��ʼ����ں���Ҿ״��� �������ݼҾ״��� ���������ɳ������ı�"
-
TG-63H 1P/20/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 20 Amp, 10kA, 400VAC
TRENT TG-63H 1P/20/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 20 Amp, 10kA, 400VAC Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB Specification TRENT Part Number TG-63H 1P/20/C/10kA Functions 1 Pole MCB - C Curve Nominal Voltage 400VAC @ 50/60Hz Nominal Current Range 20 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$6.45
$7.61 inclGST -
TG-63H 1P/50/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 50 Amp, 10kA, 400VAC
TRENT TG-63H 1P/50/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 50 Amp, 10kA, 400VAC Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB Specification TRENT Part Number TG-63H 1P/50/C/10kA Functions 1 Pole MCB - C Curve Nominal Voltage 400VAC @ 50/60Hz Nominal Current Range 50 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$6.45
$7.61 inclGST -
TG-63H 1P/6/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 6 Amp, 10kA, 230VAC
TRENT TG-63H 1P/6/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 6 Amp, 10kA, 230VAC Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB Specification TRENT Part Number TG-63H 1P/6/C/10kA Functions 1 Pole MCB - C Curve Nominal Voltage 230VAC @ 50/60Hz Nominal Current Range 10 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$6.45
$7.61 inclGST -
TG-63H 1P/32/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 32 Amp, 10kA, 400VAC
TRENT TG-63H 1P/32/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 32 Amp, 10kA, 400VAC Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB Specification TRENT Part Number TG-63H 1P/32/C/10kA Functions 1 Pole MCB - C Curve Nominal Voltage 400VAC @ 50/60Hz Nominal Current Range 32 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$6.45
$7.61 inclGST -
TG-63H 1P/63/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 63 Amp, 10kA, 400VAC
TRENT TG-63H 1P/63/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 63 Amp, 10kA, 400VAC Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB Specification TRENT Part Number TG-63H 1P/63/C/10kA Functions 1 Pole MCB - C Curve Nominal Voltage 400VAC @ 50/60Hz Nominal Current Range 63 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$6.45
$7.61 inclGST -
TG-63H 1P/16/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 16 Amp, 10kA, 400VAC
TRENT TG-63H 1P/16/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 16 Amp, 10kA, 400VAC Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB Specification TRENT Part Number TG-63H 1P/16/C/10kA Functions 1 Pole MCB - C Curve Nominal Voltage 400VAC @ 50/60Hz Nominal Current Range 16 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$6.45
$7.61 inclGST -
TG-63H 1P/10/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 10 Amp, 10kA, 400VAC
TRENT TG-63H 1P/10/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 10 Amp, 10kA, 400VAC Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB Specification TRENT Part Number TG-63H 1P/10/C/10kA Functions 1 Pole MCB - C Curve Nominal Voltage 400VAC @ 50/60Hz Nominal Current Range 10 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$6.45
$7.61 inclGST -
TG-63H 1P/25/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 25 Amp, 10kA, 400VAC
TRENT TG-63H 1P/25/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 25 Amp, 10kA, 400VAC Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB Specification TRENT Part Number TG-63H 1P/25/C/10kA Functions 1 Pole MCB - C Curve Nominal Voltage 400VAC @ 50/60Hz Nominal Current Range 25 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$6.45
$7.61 inclGST -
TG-63H 1P/40/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 40 Amp, 10kA, 400VAC
TRENT TG-63H 1P/40/C/10kA, 1 Pole Miniature Circuit Breaker C Curve 40 Amp, 10kA, 400VAC Miniature Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB Specification TRENT Part Number TG-63H 1P/40/C/10kA, Functions 1 Pole MCB - C Curve Nominal Voltage 400VAC @ 50/60Hz Nominal Current Range 40 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia Datasheet Product Datasheet
$6.45
$7.61 inclGST